• 제목/요약/키워드: instantaneous frequency

검색결과 337건 처리시간 0.031초

고주파수 전자기파를 이용한 압밀 포화토 물성치 측정을 위한 연구 (A study on measurement of physical parameters using electromagnetic wave of the compacted saturated soil)

  • 김만일;김형수;석희준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.354-361
    • /
    • 2005
  • Physical parameters such as porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) is proposed to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was $85{\sim}92%$, when FDR-V was used. This value compared favourably with 90%, which has been usually quoted in previous studies. Considering the convenience and its applicability, the measurement system of FDR-V permittivity holds a great potential in porous media and contaminant transport studies.

  • PDF

유정란 태아외부혈관 내부 혈액유동에 대한 혈류역학적 연구 (Hemodynamic Analysis of Blood Flows in the Extraembryonic Blood Vessels of Chicken Embryos)

  • 이정엽;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.6-9
    • /
    • 2008
  • Analyzing the characteristics of blood flow in the blood vessels is very important to diagnose the circulatory diseases. In order to investigate the hemodynamic characteristics in vivo, the measurements of blood flows inside the extraembryonic arterial and venous blood vessels of chicken embryos were carried out using an in vivo micro-PIV technique. The circulatory diseases are closely related with the formation of abnormal hemodynamic shear stress regions, thereby it is important to get blood velocity and vessel's morphological information according to the vessel configuration and the flow conditions. In this study, the flow images of RBCs in blood vessels were obtained using a high-speed CMOS camera with a spatial resolution of approximately 14.6${\mu}$m${\times}$14.6${\mu}$m in the whole circulation network of blood vessels. The blood flows in the veins and arteries show steady laminar and unsteady pulsatile flow characteristics, respectively. The mean blood flows merged (in veins) and bifurcated (in arteries) smoothly into the main blood vessel and branches, respectively, without any flow separation or secondary flow which accompanying large variation of shear stress. Vorticity was high in the inner regions for both types of vessels, where the radius of curvature varied greatly. The instantaneous flows in the arterial blood vessels showed noticeable pulsatility due to the heart beat, and the main features of the velocity waveforms, including pulsatile shape, retrograde flow, mean velocity, maximum velocity and pulsatile frequency, were significantly dependent on the pulsatile condition which dominates the arterial blood flow. In near future, these in vivo experimental results of blood flow measured in various extraembryonic blood vessels would be very useful to understand the hemodynamic characteristics of human blood flows and various blood flow researches for clinically useful hemodynamic discoveries as well.

  • PDF

MULTIFAN-CL 모델을 이용한 남방참다랑어 Thunnus maccoyii의 자원 평가 (Stock Assessment of the Southern Bluefin Tuna Thunnus maccoyii Using the MULTIFAN-CL Model)

  • 권유정;문대연;장창익;고정락
    • 한국수산과학회지
    • /
    • 제40권6호
    • /
    • pp.367-373
    • /
    • 2007
  • We assessed the stock of the southern bluefin tuna (SBT, Thunnus maccoyii) by applying the MULTIFAN-CL model. The model is spatially disaggregated, with the population and fisheries stratified into a number of regions within the overall stock range. Catch, effort, length-frequency, and tagging data from 1965 to 2003 were stratified by three regions and four quarters (Jan-Mar, Apr-Jun, Jul-Sept and Oct-Dec). These data were used to estimate the instantaneous fishing mortality (F), biomass, spawning biomass, recruitment, and so on. The Commission for the Conservation of Southern Bluefin Tuna (CCSBT) used only Japanese data and did not consider migration for the SBT stock assessment. By contrast, we used Japanese, Australian, New Zealand, Taiwanese, and Korean data, and considered migration. As a result, the estimated annual average F of all age classes was 0.073/yr and the F of age class 6-10 was the highest. The results also showed that the biomass and recruitment of SBT had declined significantly after 1965. Compared with the CCSBT results, the estimated spawning biomass in this study was lower and more uncertain. However, we will conduct a sensitivity analysis to get more accurate biological parameters and results. In addition, we need to use the bootstrap resampling method to quantify the uncertainty.

산지하천 유역의 한계유출량 분석을 위한 기준우량 산정 (Estimation of Trigger Rainfall for Threshold Runoff in Mountain River Watershed)

  • 김동필;김주훈;이동률
    • 한국습지학회지
    • /
    • 제14권4호
    • /
    • pp.571-580
    • /
    • 2012
  • 본 연구에서는 산지하천 유역인 설마천 유역에 대하여 GIS기법을 이용한 지형기후학적 순간단위도(GcIUH)를 유도하고, 돌발홍수 예측을 위한 기준우량을 산정하는 것을 목적으로 하고 있다. GIS기법을 적용하여 GcIUH를 유도하였으며, 유효우량을 산정하기 위한 NRCS-CN값을 산정하였다. 산정된 GcIUH를 이용하여 2011년 주요 호우사상에 대하여 분석하였다. 그 결과 전적비교의 경우 한계유출량을 초과하지 않는 것으로 분석되었으며, 사방교의 경우 모의된 첨두유출량이 약 $149.4m^3/s$로 한계유출량을 초과하는 것으로 분석되었다. 기준우량을 산정하기 위하여 50년 빈도의 설계홍수량에 해당하는 수심을 한계수심으로 설정하고, 지속기간을 고려하여 돌발홍수 기준우량을 산정하였다. 향후에는 다양한 홍수사상에 대하여 분석하고 이를 통해 한계유출량 및 기준우량의 적합성을 평가하고자 하며, 이를 바탕으로 산지하천 유역의 특성을 고려한 돌발홍수예측시스템 프로토타입을 개발하고자 한다.

$CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계 (Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF

흡기계 능동소음제어를 위한 적응형 필터 알고리즘의 개발 (Design of a New VSS-Adaptive Filter for a Potential Application of Active Noise Control to Intake System)

  • 김의열;김병현;김호욱;이상권
    • 한국소음진동공학회논문집
    • /
    • 제22권2호
    • /
    • pp.146-155
    • /
    • 2012
  • The filtered-x LMS(FX-LMS) algorithm has been applied to the active noise control(ANC) system in an acoustic duct. This algorithm is designed based on the FIR(finite impulse response) filter, but it has a slow convergence problem because of a large number of zero coefficients. In order to improve the convergence performance, the step size of the LMS algorithm was modified from fixed to variable. However, this algorithm is still not suitable for the ANC system of a short acoustic duct since the reference signal is affected by the backward acoustic wave propagated from a secondary source. Therefore, the recursive filtered-u LMS algorithm(FU-LMS) based on infinite impulse response(IIR) is developed by considering the backward acoustic propagation. This algorithm, unfortunately, generally has a stability problem. The stability problem was improved by using an error smoothing filter. In this paper, the recursive LMS algorithm with variable step size and smoothing error filter is designed. This recursive LMS algorithm, called FU-VSSLMS algorithm, uses an IIR filter. With fast convergence and good stability, this algorithm is suitable for the ANC system in a short acoustic duct such as the intake system of an automotive. This algorithm is applied to the ANC system of a short acoustic duct. The disturbance signals used as primary noise source are a sinusoidal signal embedded in white noise and the chirp signal of which the instantaneous frequency is variable. Test results demonstrate that the FU-VSSLMS algorithm has superior convergence performance to the FX-LMS algorithm and FX-LMS algorithm. It is successfully applied to the ANC system in a short duct.

탄성파 기록으로부터 기본 파형 추출에 관한 연구 (Waveform Estimation from Seismic Records)

  • 이두성
    • 지구물리와물리탐사
    • /
    • 제1권3호
    • /
    • pp.183-187
    • /
    • 1998
  • 탄성파 파형은 탄성파트레이스가 탄성파의 고유파형과 매질의 반사계수시계열과의 1차 콘볼루션이라는 가정 아래 위너적합필터(Wiener match filter)에 의하여 산출될 수 있다. 이때 매질의 반사계수 시계열은 음파 및 밀도검층 기록으로부터 도출한다. 본 논문에서는 파형 산출의 한 방법으로 탄성파 트레이스 및 반사계수 시계열을 보정하는 전처리과정의 효과를 검증하는 실험을 실시하였다. 이 전처리과정은 시간 측정은 탄성파 트레이스로부터, 그리고 반사계수는 검층 기록으로부터 잘 측정될 수 있다는 가정에 근거한다. 따라서 전처리과정은 1) 음파검층 기록의 깊이로부터 시간으로의 변환을 탄성파 트레이스에 잘 적합하도록 시작시각과 구간별 시간 길이를 조절하고, 2)탄성파 트레이스의 진폭을 검층기록에서 도출된 반사계수와 잘 적합하도록 조절하는데 이때 탄성파와 검층의 저주파 성분만을 비교한다.

  • PDF

Numerical and experimental study of unsteady wind loads on panels of a radar aerial

  • Scarabino, Ana;Sainz, Mariano Garcia;Bacchi, Federico;Delnero, J. Sebastian;Canchero, Andres
    • Wind and Structures
    • /
    • 제23권1호
    • /
    • pp.1-18
    • /
    • 2016
  • This work experimentally and numerically analyzes the flow configurations and the dynamic wind loads on panels of rectangular L/h 5:1 cross section mounted on a structural frame of rectangular bars of L/h 0.5:1, corresponding to a radar structure. The fluid dynamic interaction between panels and frame wakes imposes dynamic loads on the panels, with particular frequencies and Strouhal numbers, different from those of isolated elements. The numerical scheme is validated by comparison with mean forces and velocity spectra of a panel wake obtained by wind tunnel tests. The flow configuration is analyzed through images of the numerical simulations. For a large number of panels, as in the radar array, their wakes couple in either phase or counter-phase configurations, changing the resultant forces on each panel. Instantaneous normal and tangential force coefficients are reported; their spectra show two distinct peaks, caused by the interaction of the wakes. Finally, a scaled model of a rectangular structure comprised of panels and frame elements is tested in the boundary layer wind tunnel in order to determine the influence of the velocity variation with height and the three-dimensionality of the bulk flow around the structure. Results show that the unsteady aerodynamic loads, being strongly influenced by the vortex shedding of the supporting elements and by the global 3-D geometry of the array, differ considerably on a panel in this array from loads acting on an isolated panel, not only in magnitude, but also in frequency.

감가상각모형의 유형화에 기초한 적용방안 (Implementation Strategy Based on the Classification of Depreciation Models)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.217-230
    • /
    • 2014
  • The purpose of this study is to develop the Generalized Depreciation Function (GDF) and Winfrey Depreciation Function (WDF) by reviewing methods for the depreciation accountings. The Depreciation Accounting Models (DAM), including straight-line model, declining-balance model, sum-of-the-year-digit model and sinking fund model presented in this paper, are reclassified into the charging pattern of increasing type, decreasing type and constant type. This paper also discusses the development of the GDFs based on convex type, concave type and constant type according to the demand pattern of product, frequency of plant usage, deterioration of time, relative inadequacy, Capital Expenditure (CAPEX) and Operating Expenditure (OPEX) of the Total Productive Maintenance (TPM). The WDFs presented in this paper depict a sudden degradation of plant performance by measuring the change of TPM activity at the midpoint of useful life of asset. The WDFs are classified into left-modal type, symmetrical type and right-modal type by varying the value of skewness and kurtosis. Moreover, three increasing patterns, such as convex, concave and linear types, are used in this paper to present the distinct identification of WFDs by using Instantaneous Depreciation Rate (IDR) in terms of Performance Depreciation Function (PDF) and Depreciation Density Function (DDF). In order to have better understanding of depreciation models, the numerical examples are used for evaluating the Net Operating Less Adjusted Tax (NOPLAT) and Economic Value Added (EVA). It is concluded that the depreciation models showing a large dispersion of EVA require the adjustment of NOPLAT and Invested Capital (IC) based on the objective cash basis and net operating activity for reducing the variation of EVA.

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.