• Title/Summary/Keyword: instantaneous current control

Search Result 227, Processing Time 0.023 seconds

Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher (제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation (순시무효전력 보상에 의한 중성선 전류의 제거)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

Analysist of Instantaneous Current Tracking Control Inverter Characteristics for Photovoltaic System (태양광 발전용 순시치 전류제어형 인버터의 특성 해석)

  • 조금배;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.770-778
    • /
    • 1994
  • In this paper, the photovoltaic inverter system with instantaneous sinusoidal current tracking control is proposed to improve the utilization factor of photovoltaic power system which would be connected utility interactive system. The proposed inverter is designed to track maximum power point by two-state value control method and utility interactive operation, and to decrease output harmonics component. Optimal operating region is described by state space averaging method, and present tracking condition of standard guide line. The experimental result shows the effectiveness of inverter system using the instantaneous control method.

A Sensorless Speed Control of an Interior Permanent Magnet Synchronous Motor based on an Instantaneous Reactive Power (순시 무효전력을 이용한 매입형 영구자석 동기 전동기의 센서리스 속도제어)

  • Kang Hyoung-Seok;Joung Woo-Taik;Kim Young-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.107-115
    • /
    • 2006
  • In this paper, a new speed sensorless control based on an instantaneous reactive power is proposed for the interior permanent magnet synchronous motor(IPMSM) drives. In proposed algorithm, the current observer estimates the line currents and the estimated speed can be yielded from the voltage equation because the information of speed is included in back EMF. To implement speed sensorless control, the current observer is composed by using the voltage equation of the IPMSM in the stationary reference frame fixed to the stator. The estimated speed of the rotor is composed by using the voltage equation of the IPMSM in the rotating reference frame fixed to the rotor The estimated speeds to minimize the speed error compensated by using the instantaneous reactive power. The instantaneous reactive power is calculated on the rotating reference frame fixed to the rotor. The effectiveness of the preposed algorithm is confirmed by the experiments.

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

A new PWM method for instantaneous output current control of matrix converters with sinusoidal input current

  • Sung K. M.;Kobayashi K;Sato Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.179-183
    • /
    • 2001
  • This paper presents a simple current control strategy for matrix converters based on the extension of PWM method for inverters. A novel and efficient PWM algorithm is developed. The algorithm is verified through simulation and experiments employing a 2-kVA prototype. The results of simulation and experiment prove the instantaneous control capability of the output current with the sinusoidal input current.

  • PDF

Digital Power Control of LLC Resonant Inverter for Microwave Oven (전자레인지용 LLC 공진형 인버터의 디지털 출력 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.457-462
    • /
    • 2017
  • This paper proposes a digital power control of the LLC resonant half-bridge inverter for high power microwave oven application. Conventional half-bridge inverter for driving a microwave oven uses a hardware-based power control method which varies the frequency according to the AC source voltage. In this case, it is difficult to control the output power according to the variation of the load status of magnetron. The proposed power control consists of an instantaneous current generator and a current controller. Instantaneous current generator makes an instantaneous current reference from power command using input voltage information. Current controller controls input current which has an information of status of magnetron. The proposed power control does not require any compensation algorithm for the change of the load status of the magnetron and change of input voltage. The validity of the proposed method for the control of the change of input voltage and frequency is verified by both simulation and experiment.

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.718-725
    • /
    • 2009
  • To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.

Current Controlled PWN Inverter Using the Real-time Digital Feedback Control (실시간 디지털 궤환 제어(Deadbeat 제어)에 의한 전류 제어형 PWM 인버터에 관한 연구)

  • Lee, Jeong-Uk;Yoo, Ji-Yoon;Ahn, Ho-Gyun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.259-267
    • /
    • 1994
  • This paper describes a current control of a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. The deadbeat current controller is proposed to control the output current regardless of load component variations by the same method as voltage control. That is, in current control, with a very short sampling time and the successive feedback of the output current, the load current is mainly effected by the magnitude of load impedance rather than load component, the load current is mainly effected by the magnitude of load impedance rather than load component. Therefore, by treating the load as an impedance, the system's order is reduced and the instantaneous current control using the proposed deadeat controller is simplified.