• Title/Summary/Keyword: installation temperature

검색결과 894건 처리시간 0.023초

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 임용배
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.315-319
    • /
    • 2004
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is to compare the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

  • PDF

이중 프로세서를 이용한 컴퓨터 건조기의 전자 제어장치 성능 개선에 관한 연구 (A Study on the Improvement of Electronic Controller for Computer Dryer Using Dual Processor)

  • 박세현
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권5호
    • /
    • pp.71-79
    • /
    • 1995
  • This paper describes the design and implementation of dryer controller using the dual processor. This system has higher performance of system recovery from the noise than the existing single processor dryer. And in this paper temperature control method of Dryer using on-off fuzzy logic is proposed to improve the overshoot of temperature in dryer. Experimental results shows that the performance of fuzzy controller is better than that of controller based upon on-off control method.

  • PDF

저압 수은 방전에서의 근사화한 충돌 단면적을 사용한 전자 에너지 분포함수 해석 (The analysis of electron energy distribution function using the approximated collision cross section in the low-pressure mercury discharge)

  • 류명선;이진우;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.19-24
    • /
    • 1989
  • The electron energy distribution function in mercury discharge positive columns are calculated numerically from the Boltzmann eqation under a set of parameters, such as the electron temperature to. the atomic temperature Tw. the electron number density no. and the electric field E. Especially, using the approximation that collision cross sections only depend on the energy, the calculated electron energy distribution function was shown that it falls off rapidly in the high energy tail.

  • PDF

태양전지 전.후면의 온도차에 관한연구 (A study on the temperature difference of module's front and back)

  • 신혜영;최홍규;이근무;최경한
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2009
  • 화석연료의 문제점을 보완하고 있는 태양광발전 시스템은 태양전지 모듈의 온도에 따라 출력량이 급격히 변화하는 특성을 가지고 있다. 이러한 특성을 잘 이해하고 전력생산을 극대화 하기위해 태양전지의 온도를 낮추기 위한 방법을 고려하였다. 본 논문에서는 모듈의 전면과 후면에 똑같은 온도 감소 설비를 한 후 전 후면의 온도를 동시에 낮추는 것이 발전량에 더 큰 도움을 준다는 결론을 도출하였다.

  • PDF

Color Temperature Control of LED Floodlight Using RGB Light Color Mixing Theory

  • Kim, Gi-Hoon;Song, Sang-Bin;Cheon, Woo-Young;Kim, Jin-Hong
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2007
  • A number of R, G and B LEDs for reference color temperature mixing ratio of RGB was determined by the theory of RGB mixing as a baseline. Once the number of LEDs was determined the objective color temperature from baseline has been achieved by the control the RGB duty ratio. And a practical prototype of 50W floodlighting adjusted by the above algorithm. The micro controller was developed with control algorithm for RGB duty ratio to obtain the objective color temperature. Detailed experiments to optimize algorithm of duty ratio and color temperature will be discussed in this paper as well.

  • PDF

AFCI용 ASIC의 온도보상에 관한 연구 (A Study on the Temperature Compensation of ASIC for AFCI)

  • 양승국;이주
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.109-113
    • /
    • 2013
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. AFCI using line resistor of neutral trace needs to compensate the variation of the line resistance by temperature variation. In this paper, the ASIC including the temperature compensation circuit is implemented. The proposed implementation is verified by showing the effectiveness of an electric and a temperature characteristics for Arc signals by simulation results.

사무공간에서 형광램프 조명기구와 백색 LED 조명기구의 색온도 비교를 통한 선호도에 관한 연구 (A Study on the Preference of Fluorescent Lamp and White LEDs by the Comparison of Color Temperature in a Office Space)

  • 정연홍;김유신;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2008
  • The purpose of this study is to investigate the luminous environment of fluorescent lamp and LED lamp in a office space for various color temperature by subject response test. For this, three different color temperatures were tested for the same illuminance level. Based on such test results for various color temperatures of fluorescent lamp and white LEDs, this study is to analyze the preferences of color temperature and light source, and perceptional brightness of each light source and color temperature. Then, this study is to derive the guidelines for the performance of color temperature which are suitable on the purpose and the mood of a office space.

  • PDF

궤도보수 작업 조건별 장대레일 축력변화에 관한 연구 (A study on the Longitudinal Force Variation of CWR according to the Condition of Track Maintenance)

  • 원용환;김관형;권순정;이승열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.99-105
    • /
    • 2009
  • This research presents the method to decide proper locations for destressing of CWR using a non-destructive equipments to measure the longitudinal force(installation temperature) in CWR. The effect and necessity of destressing were analyzed by estimating changes of longitudinal force. The installation temperature was measured to find changes of longitudinal force in high speed and conventional lines before and after destressing or track maintenance at the locations where destressing was planed or where change of longitudinal force was expected during track maintenance. Past destressing was carried out within qualitative decision criteria. This research proposes the quantitative criteria to decide the priority order of the destressing locations reasonably by considering the difference of air temperature and stress free temperature during the track maintenances, the grade of ballast resistance force recovering and the length of destressing, etc.

  • PDF

제련설비용 대전류 동 Bus Bar의 온도해석 (Analysis of High Current Copper Bus Bar Temperature in Smelting Plants)

  • 곽병길;김창환;최병주;김규호;이상봉
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.26-32
    • /
    • 2014
  • In electrolysis smelting plants that using high DC current, the bus bar is most important facility for delivering the high current. The copper made bus bar is widely used for various advantages as good electrical and thermal conductivity, resonable malleability, ductility, and not rust easily. However, when high current in copper bus bar, temperature rises and maximum allowable current capacity is restricted by temperature of bus bar. In this paper, we investigated temperature variation of copper bus bar by putting cooling water channel imposed to bus bar construction. For the validity, various simulations were carried out.

고출력 백색 LED 램프의 구동조건에 따른 온도 및 광 특성 평가 (Evaluation of the Device Temperature and Optical Characteristics in High Power White LED Lamp by Driving Condition)

  • 윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.33-38
    • /
    • 2011
  • In this paper, the effect of pulse current and generated heat on characteristics of the LED is measured and evaluated. For experiments, the LED driving circuit and digital logic which determines period and duty ratio of lighting are designed. At rated current, the temperature and optical characteristics of the LED with change in duty ratio and period are compared, and those of the LED with change in duty ratio and existence of cooling fan are also compared at constant average current. As a result, frequency does not affect device temperature and optical characteristic of the LED but duty ratio does. Also, the cooling fan is less effective on those of the LED at rated current.