• Title/Summary/Keyword: installation location

Search Result 609, Processing Time 0.023 seconds

Experiments on the Effective Engine Room Ventilation in a Power Car (동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구)

  • Han, S.Y.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF

User Identification and Entrance/Exit Detection System for Smart Home (지능형 홈을 위한 사용자 식별 및 출입 감지 시스템)

  • Lee, Seon-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.3
    • /
    • pp.248-253
    • /
    • 2008
  • This paper presents a sensing system for smart home which can detect an location transition events such as entrance/exit of a member and identify the user in a group at the same time. The proposed system is compose of two sub-systems; a wireless sensor network system and a database server system. The wireless sensing system is designed as a star network where each of sensing modules with ultrasonic sensors and a Bluetooth RF module connect to a central receiver called Bluetooth access point. We propose a method to discriminate a user by measuring the height of the user. The differences in the height of users is a key feature for discrimination. At the same time, the each sensing module can recognize whether the user goes into or out a room by using two ultrasonic sensors. The server subsystem is a sort of data logging system which read the detected event from the access point and then write it into a database system. The database system could provide the location transition information to wide range of context-aware applications for smart home easily and conveniently. We evaluate the developed method with experiments for three subjects in a family with the installation of the developed system into a real house.

Development of gamma ray scanning coupled with computed tomographic technique to inspect a broken pipe structure inside laboratory scale vessel

  • Saengchantr, Dhanaj;Srisatit, Somyot;Chankow, Nares
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.800-806
    • /
    • 2019
  • This paper presents a laboratory experiment on data acquisition technique that applied to the gamma radiation scanning coupled with computed tomography (CT) technique for inspection of broken nozzle inside the vertical vessel. The acquisition technique was developed to inspect a large diameter vessel when suspicious problem location is not easily accessed. This technique allows the installation of gamma radiation source (Cesium 137, Cs-137), and detectors (Sodium Iodine. NaI(Tl)) from the accessible location to the required location and performs the scanning by designed pattern. To demonstrate the designed technique, top opened tank which installed with six cut steel pipes diameter of 76.2 mm (3") at a certain position was selected. They were assumed to be a gas riser pipes inside the vessel. Three studied cases were performed, (a) projection of well installed six pipes, (b) projection of one out of six broken pipe and (c) one of nozzle was assumed to be failure and fell down until one out of six pipes was broken and obstructed by nozzle. Results clearly indicated the capability of developed technique to distinguish between normal situation case and abnormal situation cases.

Annual energy yield prediction of building added PV system depending on the installation angle and the location in Korea (건물적용 태양광발전시스템의 국내 지역에 따른 설치각도별 연간 전력생산량 예측에 관한 연구)

  • Kim, Dong Su;Shin, U Cheol;Yoon, Jong Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • There have distinctly been no the installation criteria and maintenance management of BIPV systems, although the BIPV market is consistently going on increasing. In addition, consideration of the BIPV generation quantity which has been installed at several diverse places is currently almost behind within region in Korea. Therefore, the main aim of this study is to evaluate the BIPV generation and to be base data of reducing rate depending on regional installation angles using PVpro which was verified by measured data. Various conditions were an angle of inclination and azimuth under six major cities: Seoul, Daejeon, Daegu, Busan, Gwangju, Jeju-si for the BIPV system generation analysis. As the results, Seoul showed the lowest BIPV generation: 1,054kWh/kWp.year, and Jeju-si have 5percent more generation: 1,108.0kWh/kWp.year than Seoul on horizontal plane. Gwangju and Daejeon turned out to have similar generation of result, and Busan showed the highest generation: 1,193.5kWh/kWp.year, which was increased by over 13percent from Seoul on horizontal plane. Another result, decreasing rate of BIPV generation depending on regional included angle indicate that the best position was located on azimuth: $0^{\circ}$(The south side) following the horizontal position(an angle of inclination: $30^{\circ}$). And the direction on a south vertical position(azimuth: $0^{\circ}$, an angle of inclination: $90^{\circ}$) then turned out reducing rate about 40percent compared with the best one. Therefore, these results would be used to identify the installation angle of the BIPV module as an appropriate position.

Case studies related to the installation of tunnel ventilation towers (터널 환기탑 국내·외 설치사례연구)

  • Park, Jun Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.3
    • /
    • pp.293-304
    • /
    • 2022
  • Recently, the frequency of installation of ventilation towers is increasing due to the planning and construction of underground roads and long tunnel. In this study, implications and points for improvement were considered through investigation and analysis of the installation standards related to ventilation towers in tunnels and analysis of ventilation tower installation cases in domestic and overseas tunnel case study. As a result of this study, when selecting the location and height of the ventilation tower, it is recommended to determine the final ventilation tower type through a consultation process with residents, considering the environmental impact caused by the emission of pollutants, the harmonious arrangement with the surrounding landscape, and the efficient use of the above-ground site nearby ventilation tower. In addition, from the design stage, it is judged that a detailed review of reducing the height of the ventilation tower through air quality simulation is necessary for natural harmony with the surrounding topography and to prevent civil complaints.

Self-powered wireless bus information and disaster information system based on Internet of Things (IoT) (사물인터넷 기반의 자가 전력을 이용한 무선 버스 정보 및 재난 정보 시스템)

  • Kim, Tae-Kook
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 2022
  • This paper is a study on the self-powered wireless bus information and disaster information system based on Internet of Things (IoT). The existing bus information system supplies power and communication by cable, which causes a problem of increased installation cost and limited installation site due to cable burial. To solve this problem, a self-powered wireless bus information and disaster information system was proposed. The proposed system provides bus arrival information. Furthermore, in the event of a disaster such as a natural disaster, it can also reduce confusion and damage by notifying the disaster information through the system's speaker. In this study, a self-powered system using a solar module was proposed. As data are transmitted and received through wireless WiFi or LTE, the installation cost can be reduced and the problem of installation location restrictions can be solved.

New Train Detection Method using DC Magnetic Field Variation (직류 자기장 변화를 이용한 새로운 열차검지기법 연구)

  • Shin, Seung-Kwon;Jung, Ho-Sung;Lee, Hyung-Chul;Park, Young;Cho, Yong-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1324-1328
    • /
    • 2013
  • The reason of train location detection is generally the train interval control between the railway stations and the train path control in the railway station yard in order to avoid train collision. It is very important to know the train location for shortening the train headway, and improving the efficiency of railway maintenance as well as the safe operation of trains. Therefore, the accurate detection of train location is the prerequisite technology in railway signalling system. The track circuit and the wheel sensor of rolling stock have been used to detect the train location widely in urban railway as well as high speed train. The track circuit is continuously monitored by electrical equipment to detect the absence of the train and the tachometer and encoder is used for the wheel sensor to measure the train speed. But speed sensor failures are frequent due to the extremely harsh operating conditions encountered in rail vehicle. The CBTC(Communication based Train Control) system has been used in urban railway system recently. But the installation of CBTC system is very high and the modification of design is difficult. This paper deals with the feasibility of new train location detection method using magnetic sensors.

Experiment of Propagation for Development of the RTLS to the Consturction site (건설현장용 실시간위치결정시스템 구축을 위한 전파환경 실험)

  • Park, Jae-Sun;Lim, Sang-Boem;Pyeon, Mu-Wook;Hong, Tae-Min;Lee, Byoung-Kil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.4
    • /
    • pp.505-513
    • /
    • 2009
  • Recently, researches on the construction information for construction of high-tech cities are under performed. RTLS(Real-Time location system) for gathering the dynamic location information of construction resources in construction sites, such as workers, materials and equipments, is one of the developments. Especially, construction resources can be managed efficiently with the dynamic location information and the improvement of safety and the reduction of cost are expected. To introduce the RTLS to the construction sites, the installation location of AP(Access Point) must be simulated using the 3-dimensional visibility analysis considering the propagation distance of AP. In this research, 3-dimensional signal simulation software based on the spatial data using surveying terrestrial LiDAR is developed. The simulated results are compared with the signal strength of field experiments for 4 test sites. As a result, the signal strength from the propagation model is most similar to that of field experiment at the front of the main building and the maul playground of Konkuk University. The visibilities in that sites are higher than other sites. among 4 test sites.

Optimal Location Allocation of CCTV Using 3D Simulation (3차원 시뮬레이션을 활용한 CCTV 최적입지선정)

  • PARK, Jeong-Woo;LEE, Seong-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.92-105
    • /
    • 2016
  • This study aims to establish a simulation method for CCTV (Closed Circuit Television) sight area. The simulation incorporates variables for computing CCTV sight area including CCTV specifications and installation. Currently CCTV is used for traffic, crime prevention and fire prevention by local governments. However, new locations are selected by administrator decision rather than analysis of the optimal location. In order to determine optimum location, a method to CCTV compute range is needed, which incorporates specifications according to CCTV purpose. For this purpose, limitations of previous research methods must be recognized and the simulation method must supplement these limitations. Here in this study, we derived CCTV sight area variables for realistic analysis to complement the limitations of previous studies. A total of eight elements were derived from image device sensors and installation: wide angle, height, angle, setting height, setting angle, and others. This research implemented a 3D simulation technique that can be applied to the derived factors and automate them using ArcObject and Visual C#. This simulation method can calculate sight range in accordance with CCTV specifications. Furthermore, when installing additional CCTVs, it can derive optimal allocation position. The results of this study will provide rational choices for specification selection and CCTV location by interagency collaborative projects.

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.