• 제목/요약/키워드: installation/management

검색결과 1,166건 처리시간 0.023초

Design of Tilting Unit for Mobile Radio Communication Repeater (이동통신 중계기에 이용되는 틸팅유닛의 디자인)

  • Lee, Jung-Hyun;Park, Jae-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제21권1호
    • /
    • pp.156-160
    • /
    • 2012
  • Recently WCDMA signal transmission technology by large output microwave antenna have showed reduction of human resources and operating expense. But the existing antenna brackets cost is very expensive also its structure and functions are complicated. Unit brackets, suspending some sensors, subjected to acceleration loads, often fail due to self-vibration. To prevent such failures, it is necessary to understand the fatigue failure mode and to evaluate the fatigue life using tests or analysis techniques. The objective of this study is to develop the component test specifications, which are applicable to predict fatigue life at initial product design step, for unit brackets using vibration fatigue technique. So its application is limited to installation and management. In this project, we studied about more convenient bracket for microwave antennas through improvement on the existing antenna bracket's shortcoming and could develop an improved universal antenna bracket system for simple installation and application.

An Expert System for Demand Side Management of High Efficient in DC Servo Motor (직류서보모터의 고효율 수요관리를 위한 전문가 시스템)

  • 김광헌
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제8권3호
    • /
    • pp.71-79
    • /
    • 1994
  • 본 연구는 여러 종류의 직류서보코너에서 적용목적에 대해 최상의 성능을 발휘하면서 가장 높은 효율을 갖는 서보모터를 선정하기 위한 인간 전문가의 지식, 경험과 추론 능력을 갖는 전문가 시스템 개발에 관한 것이다. 제안한 프로그램은 비전문가가 적용시스템의 성능조건과 기계적 데이터만을 입력함으로서 고효율 서보모터가 선정되도록 하였다. 전문가 시스템의 추론기관과 지식베이스는 C 언어로 구현하였으며, 데이터베이스는 제조회사에서 제공한 직류서보모터의 카다로그로부터 구성하였다. 서로 다른 정격을 갖는 직류서보모터의 효율을 비교하는데 있어서는 속도-토크의 운전패턴에 따른 평균효율을 기준으로 하였다. 그리고, 서보모터 선정에 관한 수요관리의 전문가 시스템을 실제 사용되고 있는 여러 적용시스템에 대해 검증하여 신뢰성을 확인하였다.

  • PDF

Remote Calibration Control and Monitoring System for Conveyor Scale using LabVIEW (LabVIEW를 이용한 Conveyor Scale의 원격 교정제어 및 모니터링 시스템)

  • Bang, Nam-Soo;Jang, Woo-Jin;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제26권10호
    • /
    • pp.72-80
    • /
    • 2012
  • In general, electronic conveyor scales are installed in a relatively distributed manner on the crushed rock and sand production site. It is one of the time-consuming and difficult engineering works to monitor and control the plant operation status such as the management of measuring data, malfunction of belt conveyor, and fault of electronic conveyor scale. Therefore, to alleviate the inefficient problems and to monitor the operating plant in the online and remote control room, a remote calibration and real-time monitoring system, which is practically applied to the electronic conveyor scale system and verified by onsite experiment, is developed based on the LabVIEW.

A Study on the Economic Analysis of LED Lightings in All-Electric Houses Using California Standard Practice Test (캘리포니아 테스트를 이용한 전기에너지주택 LED조명의 경제성 분석에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyun-Ju;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제25권8호
    • /
    • pp.1-7
    • /
    • 2011
  • Recently, all-electric house technology became one of the green growth technologies and is integrated with various areas such as electricity, machinery, architecture, material, and etc. Fossil fuel energy is used for heating and hot water supply in the conventional houses but electricity is adopted in the new conceptual houses to maximize advantages of electricity such as amenity, safety, cleanness, and so on. In this paper, an economic analysis is carried out when LED lightings are adopted using the California Standard Practice Test which has been used to estimate the effects of existing DSM (Demand Side Management) programs. The results are able to contribute to the diffusion of all-electric houses and the establishment of basic data and planning for DSM policies.

Assessment of Harmonic Emission Limits for Customer at HV System (고압 수용가의 고조파 방출 한계 평가)

  • Wang, Yong-Peel;Kim, Se-Dong;Jeon, Young-Soo;Joo, Seok-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제22권12호
    • /
    • pp.110-114
    • /
    • 2008
  • In recent years, the standard for harmonics has established and applied in many countries. However a harmonic management has not performed for the absence of standard and procedure in Korea. For this reason, the standard establishment for harmonic based on the main purpose of international harmonic standards and property of domestic transmission system is required. This paper describes the software of assessment of harmonic emission limit for customer at HV System using Microsoft Excel.

A study on School Assets Management System based on Ubiquitous Sensor Network (유비쿼터스 센서네트워크를 활용한 학교자산관리시스템)

  • Park, Min-Sik;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.277-280
    • /
    • 2009
  • In this paper, the method to apply the RFID technology to schools will be presented in order to effectively integrate and manage various assets in school. The proposed system may be seemed to be very useful of individual school to grasp the status of their assets and also the central government to control and manage the assets scattered far and wide around the country. We also propose the OSN/PMS server based on EPC global standard could be appropriate especially in schools. In addition the proposed system can acquire simultaneously the information from several RFID readers at real time so that it is possible and easy to track the position, the path of moving and the status of assets in the school. To show the usefulness of the proposed system, the prototype of the system has been implemented and conducted. The proposed system seems to be applicable to various fields such as factories, farms, or homes as well as school.

  • PDF

The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use (수용가 전기설비 사고처리 시스템 및 케이블 사고사례 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2009
  • When happen the electrical facilities accident the one's diagnosis system of fault cause was constructed by FMEA method Cable accident cause is given by accident cause that can happen in each one's diagnosis and accident probability value. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual state. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF

A Study on the Leakage Current Detection System of Lighting Installation Using IoT Technology (IoT를 기반한 조명설비 누전사고 감지시스템에 관한 연구)

  • Park, Kun-Young;Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Choon-Sam;Jeon, Ho-Jin
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2018
  • In this study, we develop a leakage current detection device of lighting installation. The reed switch using in proposed device is activated when the leakage current is generated. We also design a GUI system of a management computer using LabVIEW and administrator's mobile phone app based on IoT. As results, this study is to build an IoT convergence system and it aims to protect people and property by coping with leakage current fault in real time.

  • PDF

Application of Strcutral Health Monitoring in Structual Engineering for Buildings

  • Ji Young, Kim;Hobeom, Song;Kanghyun, Park;Kwangryang, Chung
    • International Journal of High-Rise Buildings
    • /
    • 제11권3호
    • /
    • pp.221-226
    • /
    • 2022
  • Installation of Structural Health Monitoring (SHM) system is a legal obligation for high-rise buildings over 200 m or 50-floor high in South Korea. CNP Dongyang has developed key technologies for SHM system design, installation, and data analyzing. Also, CNP Dongyang has applied SHM technology to a plenty of South Korea's representative high-rise buildings. The SHM technology, also, could be used in safety management of construction phase, evaluation of structural performance, etc. In this paper, state of the art SHM technologies and their application examples are introduced to give insight for future research and practical use of SHM.

A Physical Architecture of Management Network for High-speed Transferring of Management Information (신속한 관리정보 전송을 위한 관리 망 물리구조)

  • 송명규
    • Journal of Internet Computing and Services
    • /
    • 제3권2호
    • /
    • pp.57-67
    • /
    • 2002
  • The main goal of this paper is to establish the management network structure by adopting TMN concept. Hence, the management network structure consists in layers; from management application layer to lower physical layer In this paper, TMN-DCN structure is designed. That means, since the current communication network technology has developed so fast and new and more diverse communication networks have appeared, There is a need to process each management information in fast manner, The design method of management network physical structure that enhances the efficiency in network management with prompt transmission and reception of management information is proposed and the architecture is designed as well. Although there is some increase in installation fee for total link that constitutes the physical structure in lower physical layer. network management can be promptly implemented since the structure that can transfer the management information fastest is proposed.

  • PDF