• 제목/요약/키워드: inspection.calibration

검색결과 146건 처리시간 0.033초

Relationship between porcine carcass grades and estimated traits based on conventional and non-destructive inspection methods

  • Lim, Seok-Won;Hwang, Doyon;Kim, Sangwook;Kim, Jun-Mo
    • Journal of Animal Science and Technology
    • /
    • 제64권1호
    • /
    • pp.155-165
    • /
    • 2022
  • As pork consumption increases, rapid and accurate determination of porcine carcass grades at abattoirs has become important. Non-destructive, automated inspection methods have improved slaughter efficiency in abattoirs. Furthermore, the development of a calibration equation suitable for non-destructive inspection of domestic pig breeds may lead to rapid determination of pig carcass and more objective pork grading judgement. In order to increase the efficiency of pig slaughter, the correct estimation of the automated-method that can accommodate the existing pig carcass judgement should be made. In this study, the previously developed calibration equation was verified to confirm whether the estimated traits accord with the actual measured traits of pig carcass. A total of 1,069,019 pigs, to which the developed calibration equation, was applied were used in the study and the optimal estimated regression equation for actual measured two traits (backfat thickness and hot carcass weight) was proposed using the estimated traits. The accuracy of backfat thickness and hot carcass weight traits in the estimated regression models through stepwise regression analysis was 0.840 (R2) and 0.980 (R2), respectively. By comparing the actually measured traits with the estimated traits, we proposed optimal estimated regression equation for the two measured traits, which we expect will be a cornerstone for the Korean porcine carcass grading system.

무인 선삭 셀에서의 측정/검사 시스템 (Inter-Process Inspection System Suitable for Unattended Turning Cells)

  • 김선호;김선호
    • 산업공학
    • /
    • 제5권1호
    • /
    • pp.15-23
    • /
    • 1992
  • In a transfer line with mass production capability, calibration systems are included in the process as a separate dedicated station. However, this method is not appropriate in an unattended FMC with flexibility. As the FMC produces vesatile parts with small batch sizes, more flexible calibration systems are required. In this paper, a calibration/inspection system suitable for an unattended turning cell is introduced. The system has functions of dimensional calibration of parts by touch probes, tool wear compensation, and quality monitoring of parts. Furthermore, characteristics of errors in the system are identified and corresponding compensation methodology is suggested. An operation software is developed for efficient use of the system.

  • PDF

Detection of Calibration Patterns for Camera Calibration with Irregular Lighting and Complicated Backgrounds

  • Kang, Dong-Joong;Ha, Jong-Eun;Jeong, Mun-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.746-754
    • /
    • 2008
  • This paper proposes a method to detect calibration patterns for accurate camera calibration under complicated backgrounds and uneven lighting conditions of industrial fields. Required to measure object dimensions, the preprocessing of camera calibration must be able to extract calibration points from a calibration pattern. However, industrial fields for visual inspection rarely provide the proper lighting conditions for camera calibration of a measurement system. In this paper, a probabilistic criterion is proposed to detect a local set of calibration points, which would guide the extraction of other calibration points in a cluttered background under irregular lighting conditions. If only a local part of the calibration pattern can be seen, input data can be extracted for camera calibration. In an experiment using real images, we verified that the method can be applied to camera calibration for poor quality images obtained under uneven illumination and cluttered background.

자동 선삭 셀에 적합한 인프로세스 측정/ 검사 시스템 (In-process calibration system suitable for unattended turning cells)

  • 김선호;김선호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.804-808
    • /
    • 1991
  • In a transfer line with mass production capability, calibration systems are included in the process as a separate dedicated station. However, this method is not appropriate in an unattended FMC with flexibility. As the FMC produces vesatile parts with small batch sizes, more flexible calibration systems are required. In this paper, a calibration/inspection system suitable for an unattended turning cell is introduced. The system has functions of dimension calibration of parts by touch probes, tool wear compensation, and quality monitoring of parts. Furthermore, characteristics of errors in the system are identified and corresponding compensation methodology is suggested. An operation software was developed for efficient use of the system.

  • PDF

수중탐상로봇시스템의 오차분석 및 보정 (Calibration of an underwater robotic inspection system)

  • 장종훈;김재열;김재희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.378-378
    • /
    • 2000
  • The permissible positioning error of the transducer used in reactor inspection must be within 10 mm. To implement the required precision it is necessary to manufacture all components affecting the positioning mechanism correctly and precisely. In addition, it is also necessary to handle error factors accurately. This paper describes the activities of the findings and corrections of the errors which were occurred in experiments. Those activities are; i) Categorization of error factors, ii) Cause analysis of errors, iii) Correction of errors founded in experiments by the analysis of laser induction type and by the validation of real measurement of horizontal, vertical baselines.

  • PDF

KOLAS 시험 및 교정기관 운영을 위한 개정된 표준 규정 리뷰: 적격성에 대한 일반 요구사항 (Review of Revised KOLAS Standard Regulations for Test and Calibration Laboratories: General Requirements for a Competence of Management System)

  • 김희선
    • 공업화학
    • /
    • 제31권3호
    • /
    • pp.334-337
    • /
    • 2020
  • 한국인정기구(KOLAS)는 시험 및 교정기관이 KS Q ISO/IEC 17025 요구사항에 맞추어 적절하게 운영하고 유효한 결과를 생산할 수 있도록 표준안을 제시하고 있다. 국가표준기본법(시험·검사: 시험·검사기관 인정, 교정: 국가교정제도의 확립)을 근거로 운영하고 있다. 최근, 국제시험소인정기구(ILAC)가 자격기준을 강화함에 따라 공인시험·교정기관들도 요구사항(KS Q ISO/IEC 17025:2017)에 맞추어 2020년 11월까지 전환을 완료해야 한다. 국내에서 운영되고 있는 899개 KOLAS 인정시험·검사와 교정기관이 여기에 해당된다. 여기에서는 적격성에 대한 주요 일반 요구사항을 요약하였다.

Development of a Vision-based Position Estimation System for the Inspection and Maintenance Manipulator of Steam Generator Tubes a in Nuclear Power Plant

  • Jeong, Kyung-Min;Cho, Jae-Wan;Kim, Seung-Ho;Kim, Seung-Ho;Jung, Seung-Ho;Shin, Ho-Chul;Choi, Chang-Whan;Seo, Yong-Chil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.772-777
    • /
    • 2003
  • A vision-based tool position estimation system for the inspection and maintenance manipulator working inside the steam generator bowl of nuclear power plants can help human operators ensure that the inspection probe or plug are inserted to the targeted tube. Some previous research proposed a simplified tube position verification system that counts the tubes passed through during the motion and displays only the position of the tool. In this paper, by using a general camera calibration approach, tool orientation is also estimated. In order to reduce the computation time and avoid the parameter bias problem in an ellipse fitting, a small number of edge points are collected around the large section of the ellipse boundary. Experiment results show that the camera calibration parameters, detected ellipses, and estimated tool position are appropriate.

  • PDF

형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구 (Calibration off multiple-sensor measuring system for efficient visual inspection)

  • 김승만;손석배;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

Photomask 고해상도 검사기에서 설계 데이터 비교 알고리즘 (The comparative algorithm of the design data in the photomask inspection machine with high resolution)

  • 김회섭;오창석;안태완
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2006
  • Photomask 고해상도 검사기를 개발함에 있어서 기계 설계, 제어 설계, 소프트웨어 설계 등 3개의 카테고리가 필요하다. 그 중에서 소프트웨어 설계는 CAD 데이터와 Photomask로부터 카메라로 읽어 들인 실제 영상과의 비교를 통하여 불량을 검출한다. 픽셀 단위로 비교하기 때문에 전체 영역이 커서 블록으로 나누어서 비교하는 블록 매칭 알고리즘을 사용한다. 그리고 기계 조립 정도에서 오는 오차를 보정하기 위하여 Calibration 알고리즘을 쓰고, Photomask의 곡면을 보정하기 위하여 카메라 사전 초점 알고리즘을 제시한다.

  • PDF

구조화 레이저를 이용한 PC 기반 인-라인 검사 시스템 개발에 관한 연구 (A Study on Development of PC Based In-Line Inspection System with Structure Light Laser)

  • 신찬배;김진대;임학규;이재원
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.82-90
    • /
    • 2005
  • Recently, the in-line vision inspection has become the subject of growing research area in the visual control systems and robotic intelligent fields that are required exact three-dimensional pose. The objective of this article is to study the pc based in line visual inspection with the hand-eye structure. This paper suggests three dimensional structured light measuring principle and design method of laser sensor header. The hand-eye laser sensor have been studied for a long time. However, it is very difficult to perform kinematical analysis between laser sensor and robot because the complicated mathematical process are needed for the real environments. In this problem, this paper will propose auto-calibration concept. The detail process of this methodology will be described. A new thinning algorithm and constrained hough transform method is also explained in this paper. Consequently, the developed in-line inspection module demonstrate the successful operation with hole, gap, width or V edge.