• Title/Summary/Keyword: inspection, SuRE

Search Result 6, Processing Time 0.021 seconds

Damage detection of 3D printed mold using the surface response to excitation method

  • Tashakori, Shervin;Farhangdoust, Saman;Baghalian, Amin;McDaniel, Dwayne;Tansel, Ibrahim N.;Mehrabi, Armin
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.369-376
    • /
    • 2020
  • The life of conventional steel plastic injection molds is long but manufacturing cost and time are prohibitive for using these molds for producing prototypes of products in limited numbers. Commonly used 3D printers and rapid prototyping methods are capable of directly converting the digital models of three-dimensional solid objects into solid physical parts. Depending on the 3D printer, the final product can be made from different material, such as polymer or metal. Rapid prototyping of parts with the polymeric material is typically cheaper, faster and convenient. However, the life of a polymer mold can be less than a hundred parts. Failure of a polymeric mold during the injection molding process can result in serious safety issues considering very large forces and temperatures are involved. In this study, the feasibility of the inspection of 3D printed molds with the surface response to excitation (SuRE) method was investigated. The SuRE method was originally developed for structural health monitoring and load monitoring in thin-walled plate-like structures. In this study, first, the SuRE method was used to evaluate if the variation of the strain could be monitored when loads were applied to the center of the 3D printed molds. After the successful results were obtained, the SuRE method was used to monitor the artifact (artificial damage) created at the 3D printed mold. The results showed that the SuRE method is a cost effective and robust approach for monitoring the condition of the 3D printed molds.

First isolation of Salmonella I 4,[5],12:i:- from domestic animals in Korea (국내 가축에서 Salmonella I 4,[5],12:i:-의 최초 분리 사례)

  • Lee, Deog-Yong;Kang, Min-Su;Kwon, Yong-Kuk;An, Byung-Ki;Kim, Young-Jo;Heo, Eun-Jeong;Moon, Jin San;Lee, Esther;Park, HyeMin
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.4
    • /
    • pp.285-288
    • /
    • 2012
  • Salmonella I 4,[5],12:i:- was a monophasic variant of Salmonella (S.) Typhimurium and notorious for re-emerging candidate which would replace S. Typhimurium DT104 for antibiotic resistance. Recently, isolation rate was increased on human and industrial animals but there was no case in domestic animals but human in Korea. This was first isolation case from domestic animals in Korea. The five isolates from feces of duck (n = 3), chicken (n = 1), and wild bird (n = 1) showed antibiotic resistance against cephems and aminoglycosides. These means that the spread of emerging bacterial pathogens to domestic animals and the need of systemic management for Salmonella I 4,[5],12:i:-.

Implementation Strategy and Effect Analysis of MES for a Small and Medium PCB Production Company based on BPR Methodology (BPR 방법론에 기반한 중소 PCB 제조업체의 MES 구축 전략과 효과분석)

  • Kim, Gun-Yeon;Jin, Yoo-Eui;Noh, Sang-Do;Choi, Sang-Su;Jo, Yong-Ju;Choi, Seog-Ou
    • IE interfaces
    • /
    • v.24 no.3
    • /
    • pp.231-240
    • /
    • 2011
  • Manufacturing enterprises have been doing their best endeavors to obtain competitiveness using various methodologies, such as information technology. In order to achieve competitiveness, they are adopting manufacturing execution system (MES). MES is a total management system that manages from the beginning of the production by product order until the quality inspection of the finished product. And MES is an inter-mediator for supplementation of information gap between ERP and inspection machine and equipment. This paper describes on establishment of effective strategy based on BPR methodology and implementation of MES small and medium PCB manufacturing company with multiple-types of products and mixed process flows. And then we proposed evaluation model based on balanced score card (BSC) for considering non-finance elements as well as finance elements. With evaluation model, we analyzed benefits and effects of MES.

Experience for development and capacity certification of safely relief valves (안전방출밸브 개발과 용량인증 사례)

  • Kim, Chil-Seong;No, Hui-Seon;Kim, Gang-Tae;Kim, Ji-Heon;Kim, Jong-Su
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

Radiation Exposure Dose Reduction on Upper Gastrointestinal Series (위장조영검사에서 피폭선량 저감)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Upper gastrointestinal series is non-invasive examination, and it is useful for patients or elderly patients who have difficulty in endoscopic examination because of absence of any side effects other than temporary constipation or abdominal pain. The entire image of the gastrointestinal tract can be seen and have been widely used in the diagnosis of upper gastrointestinal diseases. However, there is a possibility that radiation dose increases due to improper movement and breath control, when examination is carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. In upper gastrointestinal series to increase understanding of examination, to induce appropriate cooperation during examination, to reduce the number of retakes and shorten examination time, and to reduce dose of the subject, the procedure and precautions of the gastrointestinal test were made as a movie. We investigated the effectiveness of pre-education using the movie to reduce the inspection time, the number of re-shoots, and the reduction of exposure dose by watching the movie during the waiting time before examination. 120 patients that were selected each 20 patients aged from 30s to 80s were evaluated were evaluated for exposure dose, examination time, and the number of retakes before and after the movie training. The radiation dose, the examination time, and the number of retakes were respectively $3171.83{\mu}Gy{\cdot}m^2$ and $2931.73{\mu}Gy{\cdot}m^2$, 8.05 min, and 6.75 min, and 1.68 times and 1.22 times before and after movie training. It can be concluded that the movie training on the gastrointestinal examination influences the reduction of the examination time, the number of retakes and the reduction of the radiation dose.

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF