• Title/Summary/Keyword: inner system

Search Result 2,153, Processing Time 0.031 seconds

Development of Fan Stall Monitoring System (Fan 감시 시스템 개발에 관한 연구)

  • Cho, Hyeon-Seob;Jang, Ki-Seong;Lee, Hyung-Chung;XiaoBing, Zhao
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2482-2485
    • /
    • 2002
  • The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

  • PDF

The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji) (한지(韓紙)의 환기성능에 관한 실험적 연구)

  • 이종원;임정명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short (PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석)

  • Ko, Suk-Whan;Ju, Young-Chul;So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

Development of an Extended Kalman Filter Algorithm for the Localization of Underwater Mining Vehicles (해저 집광차량의 위치 추정을 위한 확장 칼만 필터 알고리즘)

  • WON MOON-CHEOL;CHA HYUK-SANG;HONG SUP
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.2 s.63
    • /
    • pp.82-89
    • /
    • 2005
  • This study deals with the development of the extended Kalman filter(EKF) algorithm for the localization of underwater mining vehicles. Both simulation and experimental studies in a test bed are carried out. For the experiments, a scale dawn tracked vehicle is run in a soil bin containing cohesive soil of bentonite-water mixture. To develop the EKF algorithm, we use a kinematic model including the inner/outer track slips and the slip angle for the vehicle. The measurements include the inner and outer wheel speeds from encoders, the heading angle from a compass sensor and a fiber optic rate gyro, and x and y coordinate position values from a vision system. The vision sensor replaces the LBL(Long Base Line) sonar system used in the real underwater positioning situations. Artificial noise signals mimicking the real LBL noise signal are added to the vision sensor information. To know the mean slip values of the tracks in both straight and cornering maneuver, several trial running experiments are executed before applying the EKF algorithm. Experimental results show the effectiveness of the EKF algorithm in rejecting the sensor measurements noise. Also, the simulation and experimental results show close correlations.

A Study on Model Development of Cooperative Urban Housing by Neighborhood Agreement - Case Study on the Inner Residential Area, Sunchon City - (이웃협정에 의한 협조형 도시주택의 모델개발에 관한 연구 -순천시의 도심주택지에 있어서 케이스스터디 -)

  • 김영석
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.193-204
    • /
    • 2003
  • In connection with the plan for improving the residential environment gradually by analyzing the present condition of the reconstruction and parcel form of the housing area in a inner area, the main objective of this research is to develop a cooperative urban housing model based on the neighborhood agreement. The parcel form has a structure that is inappropriate for individual reconstruction; thus, the substantial improvement only through the residential environment improvement project has its limitations. As an alternative plan to resolve such limitations, I proposed a system that enables step-by-step reconstruction within the small-scaled blocks through the annexation of the land based on the neighborhood agreement. Nonetheless, I realized that it is difficult to apply such reconstruction system to individual housing. Therefore, I presented a design concept on the cooperative urban housing project as a residential form for the reconstruction inside blocks. A model plan vouches for its effectiveness. To apply substantially the cooperative urban housing plan based on the neighborhood agreement, we need to supplement the sectional plan system.

Flow Visualization in Porous Cylinder with Partial Slots (부분 슬롯을 가진 다공성 실린더의 내부 유동 가시화)

  • Son, Min;Kim, Dohun;Koo, Jaye;Chang, Hongbeen;Kang, Moonjung
    • Journal of Aerospace System Engineering
    • /
    • v.8 no.3
    • /
    • pp.1-5
    • /
    • 2014
  • An inner flow of a porous cylinder with partial slots was visualized to study fluidic phenomena in a solid rocket motor. A high-pressure chamber and an air supply system for high flow rate were used. In order to visualize the inner flow, the smoke generator with a cam-driven pump and heaters and high speed camera were adopted. The results of the cylinder type and the partial slot type were compared. As a result, the injected smoke flow in the partial slot type had circumferential fluctuations unlike the cylinder type. It was found that the circumferential flow induced from the partial slots could be the cause of combustion instability and roll torque.

Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System (냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성)

  • Kang, Hoon;Park, Cha-Sik;Jeon, Jong-Ug;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

Performance Analysis of a Cellular Networks Using Power Control Based Frequency Reuse Partitioning

  • Mohsini, Mustafa Habibu;Kim, Seung-Yeon;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.3
    • /
    • pp.559-567
    • /
    • 2015
  • This paper focuses on evaluating the performance of a cellular network using power control based frequency reuse partitioning (FRP) in downlink (DL). In our work, in order to have the realistic environment, the spectral efficiency of the system is evaluated through traffic analysis, which most of the previous works did not consider. To further decrease the cell edge user's outage, the concept of power ratio is introduced and applied to the DL FRP based cellular network. In considering network topology, we first divide the cell coverage area into two regions, the inner and outer regions. We then allocate different sub-bands in the inner and outer regions of each cell. In the analysis, for each zone ratio, the performance of FRP system is evaluated for the given number of power ratios. We consider performance metrics such as call blocking probability, channel utilization, outage probability and effective throughput. The simulation results show that there is a significant improvement in the outage experienced by outer UEs with power control scheme compared to that with no power control scheme and an increase in overall system throughput.

A Study on the Multiphase Flow Characteristics in an Mud System (머드시스템의 다상 유동 특성 연구)

  • Lee, Wang-Do;Han, Sang-Mok;Chun, Joong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.737-744
    • /
    • 2021
  • An investigation is conducted to study a solid-liquid mixture vertically upward hydraulic transport of solid particles by non-Newtonian fluids in the Mud system. Rheology of particulate suspensions in viscoelastic fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, etc. In this study a clear acrylic pipe was used in order to observe the movement of solid particles. Annular velocities varied from 0.4 m/s to 1.2 m/s. The mud systems which were utilized included aqueous solution of sodium carboxymethyl cellulose (CMC) solutions. Main parameters considered in the study were inner-pipe rotary speed, fluid flow regime and particle injection rate. Solid volumetric concentration and pressure drops were measured for the various parameters such as inclination angle, flow rate, and rotational speed of inner cylinder.

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF