• Title/Summary/Keyword: inlet surface

검색결과 508건 처리시간 0.023초

An Experimental Study on the Pumping Performance of Molecular Drag Pumps

  • Kwon, Myoung-Keun;Hwang, Young-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1483-1491
    • /
    • 2006
  • The pumping performance of molecular drag pumps (MDP) has been investigated experimentally. The exporimented MDPs are a disk-type drag pump (DTDP), helical-type drag pump(HTDP) and compound drag pump (CDP), respectively In the case of the DTDP, spiral channels of a rotor are cut on both upper surface and lower surface of a rotating disk, and the corresponding stator is a planar disk. In the case of the HTDP, the rotor has six rectangular grooves. The CDP consists with the DTDP, at lower part, and with the HTDP, at upper part. The experiments are performed in the outlet pressure range of $0.2{\sim}533Pa$. The inlet pressure and compression ratio are measured under the various conditions of outlet pressure and throughputs, and nitrogen is used for the test gas. At the outlet pressure of 0.2Pa, the ultimate pressure has been reached to $1.0{\times}10^{-2}Pa$ for the HTDP, $1.3{\times}10^{-4}Pa$ for the DTDP, and $3.6{\times}10^{-5}Pa$ for the CDP. The maximum compression ratio of the CDP is much higher than those of the DTDP or HTDP. Consequently, the ultimate pressure of the CDP is the lowest one.

과도액정기법을 이용한 열전달 측정 및 수치해석 (Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis)

  • 홍철현;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

공기 중 축산질병 확산예측을 위한 오픈폼 도입 및 검증 (Validation and Application of OpenFOAM for Prediction of Livestock Airborne Virus Spread)

  • 노현석;서일환;이인복
    • 한국농공학회논문집
    • /
    • 제56권1호
    • /
    • pp.81-88
    • /
    • 2014
  • Accurate wind data is essential for predicting airborne spread of virus. OpenFOAM was used for computational fluid dynamics (CFD) simulation procedure which is under GNU GPL (General Public License). Using complex terrain, DEM (Digital Elevation Map) that was prepared from GIS information covering a research site is converted to a three dimensional surface mesh that is composed by quad and full hexahedral space meshes. Around this surface mesh, an extended computational domain volume was designed. Atmospheric flow boundary conditions were used at inlet and roughness height and was considered at terrain by using rough wall function. Two different wind conditions that was relatively stable during certain periods were compared in 3 different locations for validating the accuracy of the CFD computed solution. The result shows about 10 % of difference between the calculated result and measured data. This procedure can simulate a prediction of time-series data for airborne virus spread that can be used to make a web-based forecasting system of airborne virus spread.

Water Balance and Flushing Time in the Restricted Indian River Lagoon (IRL), Florida USA

  • Kim, Young-Taeg
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.75-87
    • /
    • 2003
  • The water balance calculation in the IRL shows that fresh groundwater discharge is the primary factor, with surface runoff from gaged and ungaged areas as the second freshwater contributor. Precipitation and evaporation are almost in balance fer the entire IRL. Due to high freshwater discharge from ground-water, the annual net flow is outward from the IRL to the continental shelf of the Atlantic Ocean resulting in a relatively short flushing time, denoted as $T_{0.5}$ (50% flushing time) and $T_{0.99}$ (99% flushing time). $T_{0.5}$, and. $T_{0.99}$ without a tidal effect in the Northern IRL are 17 and 114 days, respectively, during the dry season. During the wet season, they are 10 and 65 days, respectively. Tidal flushing effects are considered in central IRL due to the proximity to Sebastian Inlet. In the Northern Central zone during dry season, $T_{0.5}$, and. $T_{0.99}$ are 6 and 43 days, respectively and during the wet season 5 and 33 days. In the Southern Central zone they are 2 and 16 days for the dry season,2 and 15 days for the wet season. High groundwater seepage into the IRL is considered to be a positive effect in maintaining relatively good water quality condition even with few narrow inlets.

직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구 (An experimental study of frost forming on the horizontal cylinder under cross flow)

  • 이윤빈;노승탁
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

MPCM을 적용한 액냉형 냉각기의 성능 특성에 관한 연구 (Performance Characteristics of Liquid-Cooling Heat Exchangers with MPCM Slurry Designed for Telecommunication Equipment)

  • 전종욱;김용찬;최종민;현동수;윤린
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.710-717
    • /
    • 2007
  • Electric and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers with MPCM slurries were designed and tested by varying geometry and operating conditions. The liquid-cooling heat exchangers with 4-paths showed higher cooling performance than the others. The cooling performance of liquid cooling heat exchanger with MPCM slurries was more enhanced than that of the air cooling system. It's performance was also slightly superior to that of the water cooling system at the inlet temperature of $19^{\circ}C$.

회전하는 터빈 블레이드에서의 열전달 특성 (Detailed Heat Transfer Characteristics on Rotating Turbine Blade)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제30권11호
    • /
    • pp.1074-1083
    • /
    • 2006
  • In the present study, the effect of blade rotation on blade heat transfer is investigated by comparing with the heat transfer results for the stationary blade. The experiments are conducted in a low speed annular cascade with a single stage turbine and the turbine stage is composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has a flat tip and the mean tip clearance is 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. For the experiments, the inlet Reynolds number is $Re_c=1.5{\times}10^5$, which results in the blade rotation speed of 255.8 rpm. Blade rotation induces a relative motion between the blade and the shroud as well as a periodic variation of incoming flow. Therefore, different heat/mass transfer patterns are observed on the rotating blade, especially near the tip and on the tip. The relative motion reduces the tip leakage flow through the tip gap, which results in the reduction of the tip heat transfer. However, the effect of the tip leakage flow on the blade surface is increased because the tip leakage vortex is formed closer to the surface than the stationary case. The overall heat/mass transfer on the shroud is not affected much by the blade rotation.

Thermal and Flow Analysis in a Proton Exchange Membrane Fuel Cell

  • Jung, Hye-Mi;Koo, Ja-Ye
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1358-1370
    • /
    • 2003
  • The effects of anode, cathode, and cooling channels for a Proton Exchange Membrane Fuel Cell (PEMFC) on flow fields have been investigated numerically. Continuous open-faced fluid flow channels formed in the surface of the bipolar plates traverse the central area of the plate surface in a plurality of passes such as a serpentine manner. The pressure distributions and velocity profiles of the hydrogen, air and water channels on bipolar plates of the PEMFC are analyzed using a two-dimensional simulation. The conservation equations of mass, momentum, and energy in the three-dimensional flow solver are modified to include electro-chemical characteristics of the fuel cell. In our three-dimensional numerical simulations, the operation of electro-chemical in Membrane Electrolyte Assembly (MEA) is assumed to be steady-state, involving multi-species. Supplied gases are consumed by chemical reaction. The distributions of oxygen and hydrogen concentration with constant humidity are calculated. The concentration of hydrogen is the highest at the center region of the active area, while the concentration of oxygen is the highest at the inlet region. The flow and thermal profiles are evaluated to determine the flow patterns of gas supplied and cooling plates for an optimal fuel cell stack design.

VOCs 광촉매 분해용 $TiO_2$촉매제조 및 성능평가 (Performance Test of $TiO_2$ Catalyst in VOCs Photocatalytic Degradation)

  • 이승범;이재동;박윤신
    • 환경위생공학
    • /
    • 제20권4호통권58호
    • /
    • pp.45-50
    • /
    • 2005
  • Titania gel formations were prepared by sol-gel method using titanium(IV) chloride $(TiCl_4)$, and its characteristics were analyzed by varying the $epoxide/TiCl_4$ ratio and the amount of water In the end, titania $(TiO_2)$ aerogel were prepared using supercritical drying process. VOCs such as benzene, toluene, and m-xylene (BTX) were oxidized using prepared titania aerogel and commercially available $TiO_2$, and its performance was compared. The surface area, pore volume, and average pore diameter of 1,2-epoxybutane are significantly smaller than the propylene oxide. And the titania aerogels with 6 moi of epoxides have high surface areas, pore volumes, and average pore diameters. As a result of photo-oxidation, conversion of benzene was reached about $70\%$, and other reactants were reached about $60\%$ similarly. The conversion of BTX was increased as inlet concentration decreased. The reactivity of titania calcined at $600^{\circ}C$ was greater than $400^{\circ}C$ and $800^{\circ}C$. Water is required as a reactants for the oxidation of VOCs, and the continuous consumption of hydroxyl radicals required replenishments to maintain catalyst activity. The activity ratio increased with increasing reaction time when enough amount of water was present in the reactor.

비정상 후류가 선형터빈익렬의 유동 및 열전달에 미치는 영향에 관한 연구 (Influence of the Unsteady Wake on the Flow and Heat Transfer in a Linear Turbine Cascade)

  • 윤순현;심재경;김동건
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.164-170
    • /
    • 2001
  • The influence of unsteady wake on the flow and heat transfer characteristics in a four-vane linear cascade was experimentally investigated. The unsteady wake was generated with four rotating rectangular plates located upstream of the cascade. Tested inlet Reynolds number based on chord length was set to 66,000 by controlling free-stream velocity. A hot-wire anemometer system was employed to measure turbulent velocity components. For the convective heat transfer coefficients measurement on turbine blade surface, thermochromic liquid crystal and gold film Intrex were used. It was found that the unsteady wake enhances the turbulent motion in the cascade passage and accordingly promotes the development and transition of boundary layer. It was found that the heat transfer coefficients on the blade surface increase as the plate rotating speed increases. However, the increasing of heat transfer coefficients is not significant in the case that Strouhal number is higher than 0.503.