연속흐름 반응기에서 광촉매 반응에 의한 VOC 물질제거 특성에 대한 수치적 연구 (A Numerical Analysis of the Abatement of VOC with Photocatalytic Reaction in a Flow Reactor)

  • 최우혁;김창녕;정석진
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.637-646
    • /
    • 2001
  • VOC(Volatile Organic Compound) removal characteristics in continuous flow reactors have been numerically investigated. The photocatalytic reaction have been simulated with the binding constant and the reaction rate constant obtained from experimental data for the constant-volume batch reactor, and then VOC abatement in continuous flow reactors with the same conditions as those of batch reactor has been analyzed. The standard 4\kappa-\varepsilon$ model and mass conservation equation have been employed for numerical calculation, and heterogeneous reaction rate has been used in terms of the boundary condition of the conservation equation. in the case of the continuous flow reactor, reaction characteristics have been estimated with various inlet velocities and with different number of baffles. The result shows that the concentration distribution and flow patterns are strongly affected by the inlet velocity, and that with the increased inlet velocity, VOC removal rate is increased, while removal efficiency is decreased. This result may be useful in the design of reactors with improved VOC removal efficiency.

  • PDF

다기통 엔진 흡기시스템의 유동해석 모델개발 (Development of a numerical flow model for the multi-cylinder engine intake system)

  • 송재원;성낙원
    • 대한기계학회논문집B
    • /
    • 제20권6호
    • /
    • pp.1921-1930
    • /
    • 1996
  • To design an optimum engine intake system, a flow model for the intake manifold was developed by the finite difference method. The flow in the intake manifold was one-dimensional, and the finite difference equations were derived from governing equations of flow, continuity, momentum and energy. The thermodynamic properties of the cylinder were found by the first law of thermodynamics, and the boundary conditions were formulated using steady flow model. By comparing the calculated results with experimental data, the appropriate boundary conditions and convergence limits for the flow model were established. From this model, the optimum manifold lengths at different engine operating conditions were investigated. The optimum manifold length became shorter when the engine speeds were increased. The effect of intake valve timings on inlet air mass was also studied by this model. Advancing intake valve opening decreased inlet air mass slightly, and the optimum intake valve closing was found. The difference in inlet air mass between cylinders was very small in this engine.

변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구 (A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer)

  • 권석두;남상천
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF

연료노즐 내부유동 현상의 수치해석 (Calculation of the internal flow in a fuel nozzle)

  • 구자예;박장혁;오두석;정홍철
    • 대한기계학회논문집B
    • /
    • 제20권6호
    • /
    • pp.1971-1982
    • /
    • 1996
  • The breakup of liquid jet is the result of competing, unstable hydrodynamic forces acting on the liquid jet as it exit the nozzle. The nozzle geometry and up-stream injection conditions affect the characteristics of flow inside the nozzle, such as turbulence and cavitation bubbles. A set of calculation of the internal flow in a single hole type nozzle were performed using a two dimensional flow simulation under different nozzle geometry and up-stream flow conditions. The calculation showed that the turbulent intensity and discharge coefficient are related to needle position. The diesel nozzle with sharp inlet under actual engine condition has possibility of cavitation, but round inlet nozzle has no possibility of cavitation.

환자 특정 경동맥 분기부 모델 혈류유동에 대한 입구부 이차곡률의 영향 (Influence of Inlet Secondary Curvature on Hemodynamics in Subject-Specific Model of Carotid Bifurcations)

  • 이상욱
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.479-486
    • /
    • 2011
  • 의료영상을 기반으로 한 경동맥 분기부 혈류유동장 전산유체역학 해석의 수행에 있어 입구부 경계 조건 도출을 위한 환자 특정 시간 변동 상세 유속 분포를 얻는 것은 일반적으로 쉽지 않다. 그러므로 대부분의 경우 계측된 혈류량을 바탕으로 이상적인 축대칭 완전발달 유속 분포를 적용하게 된다. 그러나 MRI로 직접 계측한 총경동맥 혈류 유속분포를 적용한 기존의 연구에서 입구부 유속분포 경계 조건이 경동맥 분기부 혈류 유동장 해석 결과에 중요한 영향을 미친다는 것을 보였으며, 특히 계측된 혈류 유속분포가 전형적인 Dean type 유동과 다른 독특한 형태를 가진다는 것을 보고하였다. 본 연구에서는 이러한 독특한 형태의 유속 분포가 경동맥 입구부 형상의 이차곡률에 의해 생성됨을 보이고, 직접 경동맥 분기부 유동장 CFD 해석의 경계 조건으로 적용하여 이의 영향을 조사하였다. 이를 통하여 충분한 길이의 실제 경동맥 입구부 형상을 적용 할 경우, 입구부 경계 조건의 영향이 의료영상으로 부터 혈관 형상을 도출하는 과정에서 불가피하게 유기되는 영상 처리 오차에 의한 영향에 비해 상대적으로 크지 않음을 알 수 있었다.

타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향 (Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient)

  • 윤재동;이영훈;성재용
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

Experimental and numerical investigation on the pressure pulsation in reactor coolant pumps under different inflow conditions

  • Song Huang;Yu Song;Junlian Yin;Rui Xu;Dezhong Wang
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1310-1323
    • /
    • 2023
  • A reactor coolant pump (RCP) is essential for transporting coolant in the primary loop of pressurized water reactors. In the advanced passive reactor, the absence of a long pipeline between the steam generator and RCP serves as a transition section, resulting in a non-uniform flow field at the pump inlet. Therefore, the characteristics of the pump should be investigated under non-uniform flow to determine its influence on the pump. In this study, the pressure pulsation characteristics were examined in the time and frequency domains, and the sources of low-frequency and high-amplitude signals were analyzed using wavelet coherence analysis and numerical simulation. From computational fluid dynamics (CFD) results, non-uniform inflow has a great effect on the flow structures in the pump's inlet. The pressure pulsation in the pump at the rated flow increased by 78-128.7% under the non-uniform inflow condition in comparison with that observed under the uniform inflow condition. Furthermore, a low-frequency signal with a high amplitude was observed, whose energy increased significantly under non-uniform flow. The wavelet coherence and CFD analysis verified that the source of this signal was the low-frequency pulsating vortex under the steam generator.

임펠러 형상에 따른 양흡입 원심송풍기 성능특성 (Performance Characteristics of the Double-Inlet Centrifugal Blower according to the Shape of an Impeller)

  • 이종성;장춘만
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.28-34
    • /
    • 2014
  • This paper presents the performance enhancement of a double-inlet centrifugal blower by the shape optimization of an impeller. Two design variables, a number of blade and a length of chord, are introduced, and analyzed by a response surface method. Three-dimensional compressible Navier-Stokes equations are used to analyze the blower performance and the internal flow of the blower. Throughout the numerical simulation of the blower, blower efficiency can be increased by reducing separation flow generating from the blade leading edge of a blade pressure surface. It is noted that recirculation flow observed inside the blade passage induces low velocity region, thus increases pressure loss. Efficiency and pressure of the optimum blower are successfully increased up to 3% and 3.9% compared to those of reference blower at the design flow condition, respectively. Detailed flow field inside the blower is also analyzed and compared.

환상이중원관에서 R-113의 비등열전달에 관한 연구 (A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube)

  • 김명환;김철환;오철;윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

Numerical Analysis of Flow in Radial Turbine (Effects of Nozzle Vane Angle on Internal Flow)

  • OTSUKA, Kenta;KOMATSU, Tomoya;TSUJITA, Hoshio;YAMAGUCHI, Satoshi;YAMAGATA, Akihiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.137-142
    • /
    • 2016
  • Variable Geometry System (VGS) is widely applied to the nozzle vane for the radial inflow turbine constituting automotive turbochargers for the purpose of optimizing the power output at each operating condition. In order to improve the performance of radial turbines with VGS, it is necessary to clarify the influences of the setting angle of nozzle vane on the internal flow of radial turbine. However, the experimental measurements are considered to be difficult for the flow in radial turbines because of the small size and the high rotational speed. In the present study, the numerical calculations were carried out for the flow in the radial turbine at three operating conditions by applying the corresponding nozzle vane exit angles, which were set up in the experimental study, as the inlet boundary condition. The numerical results revealed the characteristic flow behaviors at each operating condition.