• Title/Summary/Keyword: inlet

Search Result 4,348, Processing Time 0.031 seconds

Fluid Injection Simulation Considering Distinct Element Behavior and Fluid Flow into the Ground (지반내 입자거동 및 흐름을 고려한 수압작용 모델링)

  • Jeon, Je-Sung;Kim, Ki-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2008
  • It is interesting to note that distinct element method has been used extensively to model the response of micro and discontinuous behavior in geomechanics. Impressive advances related to response of distinct particles have been conducted and there were difficulties in considering fluid effect simultaneously. Current distinct element methods are progressively developed to solve particle-fluid coupling focused on fluid flow through soil, rock or porous medium. In this research, numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. After generation of initial particles and wall elements, confining stress was applied by servo-control method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell. Fluid was injected as 7-step into the assembly in the x-direction from the inlet located at the center of the left boundary under confining stress condition, $0.1MP{\alpha}\;and\;0.5MP{\alpha}$, respectively. For each simulation, movement of particles, flow rate, fluid velocity, pressure history, wall stress including cavity initiation and propagation by interaction of flulid-paricles were analyzed.

Experimental Study on the Diagnosis and Failure Prediction for Long-term Performance of ESP to Optimize Operation in Oil and Gas Wells (유·가스정 최적 운영을 위한 ESP의 장기 성능 진단 및 고장 예측 실험 연구)

  • Sung-Jea Lee;Jun-Ho Choi;Jeong-Hwan Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.71-78
    • /
    • 2023
  • In general, electric submersible pumps (ESPs), which have an average life of 1.0 to 1.5 years, experience a decrease in performance and a reduction in life of the pump depending on oil and gas reservoir characteristics and operating conditions in wells. As the result, the failure of ESP causes high well workover costs due to retrieval and installation, and additional costs due to shut down. In this study, a flow loop system was designed and established to predict the life of ESP in long­term operation of oil and gas wells, and the life cycle data of ESP from the time of installation to the time of failure was acquired and analyzed. Among the data acquired from the system, flow rate, inlet and outlet temperature and pressure, and the data of the vibrator installed on the outside of ESP were analyzed, and then the performance status according to long-term operation was classified into five stages: normal, advice I, advice II, maintenance, and failed. Through the experiments, it was found that there was a difference in the data trend by stage during the long­term operation of the ESP, and then the condition of the ESP was diagnosed and the failure of the pump was predicted according to the operating time. The results derived from this study can be used to develop a failure prediction program and data analysis algorithm for monitoring the condition of ESPs operated in oil and gas wells.

Biodegradation of VOC Mixtures using a Bioactive Foam Reactor II: Analysis of Microbial Community (계면활성제 미생물반응기의(혼합 VOCs) 생분해 II: 미생물의 군집해석)

  • Jang, Hyun Sup;Shin, Shoung Kyu;Song, Ji Hyeon;Hwang, Sun Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.695-701
    • /
    • 2006
  • A toluene-degrading bacterial strain was isolated from a mixed culture that was maintained using toluene as a sole carbon and energy source. The isolated bacterium was classified as Pseudomonas sp. TBD4 based on the close relationship to bacteria belonging to this genus. A bottle study to determine biodegradation rates of individual aromatic compounds showed that the biodegradation was faster in the order of toluene, benzene, styrene, and p-xylene. However, when various mixtures were subjected to TDB4, styrene was degraded at the highest rate, indicating that both toluene and p-xylene could stimulate the degradation of other substrates whereas styrene played as an inhibitor. In addition, the mixed culture and TDB4 were inoculated to the bioactive foam reactor (BFR), and the reactor performance and the corresponding change of microbial community were monitored using the fluorescent in situ hybridization (FISH) method. When an inlet concentration of the VOC mixture increased to greater than 250 ppm, the overall removal efficiency dropped significantly. The FISH measurement demonstrated that the ratio of TDB4 to the total bacteria also decreased to less than 20% along with the decline in removal efficiency in the BFR. As a result, the periodic addition of the pre-grown TDB4 might have been beneficial to achieve a stable performance in the BFR operated over an extended period.

Biodegradation of VOC Mixtures using a Bioactive Foam Reactor I: Reactor Performance (계면활성제 미생물반응기의(혼합 VOCs) 생분해 I: 반응기 거동평가)

  • Shin, Shoung Kyu;Jang, Hyun Sup;Hwang, Sun Jin;Song, Ji Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.689-694
    • /
    • 2006
  • The system performance of a bioactive foam reactor (BFR), that consists of a foam column using a surfactant and a biodegradation basin containing suspended bacteria, was investigated for the treatment of gaseous toluene or a mixture of four volatile organic compounds (VOCs, benzene, toluene, p-xylene, and styrene). Overall, the BFR achieved stable VOC removal efficiencies, indicating that it can be used as a potential alternative over conventional packed-bed biofilters. Furthermore, a dynamic loading test showed that relatively constant removal was maintained at the elevated loading due to a high mass transfer rate in the foam column. However, as the inlet concentration of VOCs increased, a portion of the VOCs mass-transferred to the liquid phase was stripped out from the biodegradation basin, resulting in a decrease in the overall removal efficiency. In the BFR, the removal efficiency of the individual VOC was mainly determined depending on the biodegradation rate (styrene > toluene > benzene > p-xylene), rather than the mass transfer rate. Consequently, increases in the microbial activity and the volume of the basin could improve the overall performance of the BFR system. Further investigation on microbial activity and community dynamics is required for the BFR when subjected to high loadings of VOC mixtures.

Backflow Flow Analysis of Street Inlet drain using Fluent Model (빗물받이 연결관 역류 흐름 해석을 위한 Fluent 모형 적용)

  • Lee, Min Sung;Kim, Jung Soo;Yoo, In Gi;Yoo, Kyu Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.245-245
    • /
    • 2022
  • 최근 국내 기후변화에 따른 국지성 집중호우로 인한 시간당 강우량의 증가로 도로부 유출량의 증가와 배수관거에서의 내수배제 불량에 따른 도심지 내수침수 피해가 증가함에 따라 이를 해결하기 위한 우수유출저감시설이 설치되고 있다. 그러나 대단위의 지하 저류시설의 지속적인 설치는 과밀화된 도심지에서 설치 지하공간의 구조적인 한계 및 적정 설치 위치의 미확보 등의 다양한 문제가 발생하여 저류시설의 침수저감 효과에 대한 추가적이고 새로운 저류시설에 대한 연구가 필요한 실정이다. 이에 내수 침수 저감 및 배수 능력 향상을 위한 도로 배수시설과 연계된 도로 측구부 저류시스템 구축이 필요하다. 이를 위해 역류 방지 및 노면수 저류 빗물받이에 적용되는 부력식 역류차단장치를 개발하였으며, 역류차단장치의 최적 형상 개발을 위해서 기존 빗물받이 연결관과의 통수능 비교 및 분석이 필요한 실정이다. 따라서 본 연구에서는 기존 빗물받이 연결관 및 연결관 내에 역류차단장치가 적용된 역류차단 빗물받이의 흐름분석을 위해 Fluent 모형을 이용하여 3차원 수치모의를 수행하였다. 수치모의 구성으로는 전체 형상을 40×50cm의 빗물받이 유입부와 50×50cm의 빗물받이로 결정하고 격자는 빗물받이 내부의 복잡한 3차원 흐름을 모의하기 위해 1.2~2mm 크기로 생성하였다. 다상유동 해석을 위해 VOF(Volume of Fluid)방법을 적용하였고, 수치해석 방법으로는 비정상류, 난류 모형으로는 SST k-𝜔모형을 적용하였다. 해석조건으로는 김정수(2021) 등이 제시한 4차선 기준 설계빈도별(5~30년) 빗물받이 유입유량을 산정하여 빗물받이 유입조건으로 선정하였으며, 빗물받이와 연결관에서의 통수능력 분석 조건으로는 빗물받이에 기존 연결관이 부착된 조건과 연결관 내에 역류차단장치가 설치되어 역류차단장치가 개방된 조건에서의 통수능을 비교하였으며, 역류상황을 가정한 연결관에서의 통수능을 비교하기 위하여 역류차단장치의 개폐정도를 15도(통수단면 33%감소) 닫힌 상태 및 30도(통수단면 67% 감소) 닫힌 상태 조건을 대상으로 빗물받이와 연결관에서의 흐름을 모의하였다. 수치모의 결과 역류차단장치의 계폐조건에 상관없이 5년 빈도유입량 조건에서는 완전 배수가 되었으며, 개폐조건 15도에서는 10년 빈도의 유입량에서는 완전 배수가 되었으나 20년 빈도 이상의 유입량 조건에서 빗물받이 유입부로의 역류가 발생하였으며, 개폐조건 30도에서는 5년 빈도 이상 유입량 조건에서 빗물받이 유입부로 역류가 발생하는 것으로 나타났다. 특히, 30년 빈도 이상의 유입량부터는 빗물받이 연결관 내에 역류차단장치 개페조건과 관계없이 빗물받이 유입부로의 역류로 인한 도로 침수가 발생하기 때문에 유휴공간인 도로 측구부를 저류공간으로 활용할 수 있는 도로 측구부 저류시스템의 구축은 필수적이라고 판단되며, 유량 조건에 따른 빗물받이 내부 와 흐름과 유출부에서의 유속 변화 특성을 확인하였다. 그러므로 측구 저류조 개발 형상과 연결한 3차원 흐름의 구현 및 분석에 Fluent 모형의 적용이 가능하다고 판단된다.

  • PDF

Optimization of impeller blade shape for high-performance and low-noise centrifugal pump (고성능 저소음 원심펌프 개발을 위한 임펠러 익형 최적설계)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Tae-hoon Kim;Junhyo Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2023
  • The aim of this study was to enhance the flow rate and noise performance of a centrifugal pump in dishwashers by designing an optimized impeller shape through numerical and experimental investigations. To evaluate the performance of the target centrifugal pump, experiment was conducted using a pump performance tester and noise experiment was carried out in a semi-anechoic chamber with microphones and a reflecting wall behind the dishwasher. Through the use of advanced computational fluid dynamics techniques, numerical simulations were performed to analyze the flow and aeroacoustics performance of our target centrifugal pump impeller. To achieve this, numerical simulations were carried out using the Reynolds-Average Navier-Stokes equations and Ffowcs-Willliams and Hawkings equations as governing equations. In order to ensure the validity of numerical methods, a thorough comparison of numerical results with experimental results. After having confirmed the reliability of the current numerical method of this study, the optimization of the target centrifugal pump impeller was conducted. An improvement in flow rate was confirmed numerically, and a manufactured proto-type of the optimized model was used for experimental investigation. Furthermore, it was observed that by applying the fan law, we could effectively reduce noise levels without reducing the flow rate.

Salinity Changes and Bottom Water Particle Exchange Simulations in Response to Sluice Gate Operations at Saemangeum Lake (새만금 배수갑문 운영에 따른 염분 변화와 저층수의 입자교환 모의)

  • Seonghwa Park;Jonggu Kim;Minsun Kwon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.562-575
    • /
    • 2023
  • In an effort to improve water quality, the South Korean government has implemented measures to increase seawater circulation in Saemangeum Lake. We analyzed the effect of increasing the frequency of seawater circulation based on salinity levels and bottom water exchange in the lake, using an environmental fluid dynamics code model. When the sluice gate opening and shutting frequency increased from once to twice per day, the internal water level of Saemangeum Lake increased by up to ~0.7 m. The salinity increased by 2.12 psu near the western breakwater and decreased by 1.18 psu near the freshwater inlet. We analyzed the extent of bottom water exchange using a particle tracing method and observed that the residual rate of particles shallower than 5 m in water depth decreased by 2.52% in Case 2 (opening and shutting twice per day) compared to Case 1 (opening and shutting once per day). This indicates that increasing the frequency of sluice gate opening and shutting would promote enhanced bottom water exchange. Consequently, the increased salinity and bottom water exchange associated with increased seawater circulation are expected to improve water quality in Saemangeum Lake.

Seasonal Paddy Management Options for the Safe Use of Golden Apple Snails (Pomacea canaliculata) in Eco-friendly Rice Cultivation (친환경 벼 재배지에서 왕우렁이(Pomacea canaliculata) 안전사용을 위한 시기별 논 관리요령)

  • Lee, Jin-Hee;Choi, Duck-Soo;Kim, Hyo-Jeong․;Cho, A-Hae;Kim, Ji-In;Hong, Sung-Jun
    • Korean Journal of Organic Agriculture
    • /
    • v.31 no.4
    • /
    • pp.413-426
    • /
    • 2023
  • These experiments were conducted for 3 years from 2021 to 2023 to develop a method that can be safely used to prevent the leakage of Golden apple snails (Pomacea canaliculata) from eco-friendly rice plantations. In the southern part of Jeollanam-do, after planting rice, the young golden apple snails placed in the rice field become adults around mid-July and begin spawning. These individuals can overwinter in drains that do not dry out, but individuals hatched after mid-July will not mature enough to overwinter. The size of golden apple snails overwintered in the drainage canal was more than 2.5cm in shell height. Installing a net at the inlet could block 95% of the inflow of snails, and 99% of outflow was blocked by installing an improved water trap and net at the drain. During the mid-drying period and pre-harvest drying period, a water path was created with a power paddy pottery machine. 59.5% of snails were attracted to the waterway, and it took 130 minutes to build the waterway and collect the snails. Based on these results, seasonal paddy management tips for the safe use of giant snails in rice fields were suggested.

Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process (압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.123-133
    • /
    • 2023
  • Commercial hydrogen fuel cell vehicles are charged by compressing gaseous hydrogen to high pressure and storing it in a storage tank in the vehicle. This process causes the temperature of the gas to rise, to ensure the safety to storage tanks, the temperature is limited. Therefore, a heat transfer model is needed to explain this temperature rise. The heat transfer model includes the convective heat transfer phenomenon, and accurate estimation is required. In this study, the convective heat transfer coefficient in the hydrogen fueling process was calculated and compared using various correlation equations considering physical phenomena. The hydrogen fueling process was classified into the fueling line from the dispenser to the tank inlet and the storage tank in the vehicle, and the convective heat transfer coefficients were estimated according to process parameters such as mass flow rate, diameter, temperature and pressure. As a result, in the case of the inside of the filling line, the convective heat transfer coefficient was about 1000 times larger than that of the inside of the storage tank, and in the case of the outside of the filling line, the convective heat transfer coefficient was about 3 times larger than that of the outside of the storage tank. Finally, as a result of a comprehensive analysis of convective heat transfer coefficients in each process, it was found that outside the storage tank was lowest in the entire hydrogen fueling process, thus dominated the heat transfer phenomenon.

Development of a Rotation Swab Pig Method for Cleaning Water Pipes (상수관의 세척을 위한 회전식 스왑피그 공법 개발)

  • Kicheol Lee;Jaeho Kim;Kisung Kim;Jeongjun Park
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Drinking water is an essential element to ensure the basic human right to live, and the quality of clean water must always be ensured. However, domestic water facilities, which were installed intensively in the early 2000s, are deteriorating. The accidents such as discoloration of water such as chromaticity and turbidity as well as leakage of substances frequently occur. However, since it is virtually impossible to replace all water pipes, the detailed standards for maintenance of water pipe network facilities established in 2021 require water pipe cleaning. The swab pig method, one of the water pipe cleaning methods, is a method of physically removing substances in pipes and is evaluated as having the highest cleaning efficiency. However, Swab is highly likely to be damaged or deformed during the cleaning process, and may even be lost. Therefore, in this study, the material of the pig was changed to a material with high compressibility, and it was made as close as possible to the inner wall of the water pipe. And, to maximize cleaning efficiency, a rotation swab pig with a rotation blade was developed. In addition, high-strength wire and winding equipment were additionally developed to eliminate the possibility of loss and to determine the location of the pig. The inlet and outlet are connected with wires, and after verifying the performance of each detailed technology, the technology was applied on a test bed with a 30m section. As a result of the application, the performance of the technology was verified by measuring the process time and evaluating applicability.