• Title/Summary/Keyword: injection grouting

Search Result 195, Processing Time 0.018 seconds

A Study on the Reinforcement Effect of Low Flow Mortal Injection Method Using Field Test (현장시험을 이용한 저유동성 몰탈주입공법의 보강효과에 관한 연구)

  • Junyeong Jang;Gwangnam Lee;Daehyeon Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.599-609
    • /
    • 2023
  • In the seismic retrofitting of harbor breakwaters in Korea, the recovery rate is often uncertain due to site conditions and site conditions, and problems continue to arise. Therefore, in this study, we analyzed the recovery rate and compressive strength of the improved material through drilling survey by grouting confirmation method after applying low-fluidity mortar injection method, and furthermore, we checked the elastic modulus by downhole test and tomography to confirm the reinforcement effect of soft ground after ground improvement. The experimental results showed that the average shear wave velocity of the ground increased from 229 m/s to 288 m/s in BH-1 and BH-3 boreholes to a depth of 28.0 m, and the average shear wave velocity of the ground to a depth of 30.0 m tended to increase from 224 m/s to 282 m/s in the downhole test. This is believed to be a result of the increased stiffness of the ground after reinforcement. The results of the tomographic survey showed that the Vs of the soft ground of the sample at Site 1 increased from 113 m/s to 214 m/s, and the Vs of the sample at Site 2 increased from 120 m/s to 224 m/s. This shows that the stiffness of the ground after seismic reinforcement is reinforced with hard soil, as the Vs value satisfies 180 m/s to 360 m/s in the classification of rock quality according to shear wave velocity.

Case Study of Improvement against Leakage of a Sea Dike under Construction (해안제방 시공 중 해수유입에 대한 차수보강 사례분석)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Kim, Hong-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • In this study, the causes and countermeasures for the leakage of a sea dyke under construction are analyzed. In general, the seabed ground is clearly divided from the embankment but a lot of parts show abnormal zones with low resistivity from the results of electric resistivity survey. Hence the causes of the leakage are considered as following: three-dimensional shear strain behavior, irregular compulsory replacement of the soft seabed ground with low strength and quality deterioration of the waterproof sheets during the closing process. The improvement method is determined by considering the constructability in the seawater and its velocity condition, durability, economic feasibility, similar application cases and so on. Consequently, a combination of low slump mortar and slurry grouting and injection method is selected as an optimum combination. Mixing ratio and improvement pattern are determined after drilling investigation and pilot test. The improvement boundary is separated into general and intense leakage area. The construction is performed with each pattern and the improvement effects are confirmed. The confirmed effects with various tests after completion show tolerable ranges for all of the established standards. Finally, various issues such as prediction of length of the waterproof sheet, installation of it against seawater velocity, etc. should be considered when sea dykes are designed or executed around the western sea which has high tide difference.

Evaluation of a Ground Heat Exchanger Appropriate for the Site of the Third Stage Construction of Incheon International Airport (인천국제공항 3단계 건설부지에 적합한 지중열교환기 시스템 평가 연구)

  • Cho, Nam-Hyun;Song, Jung-Tae;Yoon, Seok;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.23-33
    • /
    • 2015
  • In the present study, a ground heat exchanger was installed for each heat source in the system at the site to evaluate ground heat conductivity, constructability, and economic feasibility; the factors considered in the study included ground heat, groundwater, fillers (such as bentonite and pea pebbles) and the shape of the heat exchange pipe (e.g., U and D-U). The aim was to determine the ground heat exchanger appropriate for the geothermal system in the 3rd-phase construction of Incheon International Airport. A comparative cost analysis of the initial costs based on the above information showed that although the initial costs of the regular vertical closed loop-II and modified vertical closed loop were lower than those of the regular vertical closed loop-I, they could not be expected to deliver high economic efficiency from the viewpoint of constructability (filler injection, heat exchange pipe insertion). The initial costs proved to be higher in the case of Geohil.

Evaluation of Grouting Effect by Injection Materials Using Geophysical Logging (물리검층을 이용한 주입재에 따른 그라우팅 효과 판정)

  • Choe, Jeong-Yeol;Park, Sang-Gyu;Im, Guk-Muk;Song, Mu-Yeong
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.98-98
    • /
    • 2010
  • 그라우팅은 지반의 공학적인 강도증가를 통한 지지력 향상 및 암반의 투수성 저감을 통해 지하수 유동을 억제하기 위하여 대규모 토목공사 현장의 균열암반 및 댐 또는 제방 등의 지역에서 많이 시행되고 있다. 본 연구는 균열암반지역에서 그라우팅 효과 확인을 위하여 보통 포틀랜드 시멘트(OPC)와 마이크로 시멘트(MC)를 사용하여 그라우팅을 수행하였으며, 그라우팅 전후에 물리검층(시추공영상촬영, 초음파 텔레뷰어검층)을 이용하여 그라우팅 효과 정도를 파악하였다. 연구지역은 경상북도 영주시 평은면 지역으로, 지질은 선캠브리아기 안구상편마암에 시대미상의 흑운모 화강암이 관입을 하였고, 이를 제4기의 충적층이 부정합으로 피복되어 있다. 그라우팅은 일반구간과 단층대구간으로 구분하여 실시하였으며, 두 구간의 이격거리는 서로의 간섭을 피하기 위해 약 40m 간격으로 선정하였다. 주입재(OPC, MC)는 5개의 주입공에서 triangle 방향으로 주입하였으며, 주입정도를 확인하기 위하여 각 구간에 2공씩 확인시추를 하였다. 두 개의 site중 일반구간의 보통 포틀랜드시멘트 주입결과 평균주입량은 48.2kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 1.62kg/m이며, 마이크로시멘트의 평균주입량은 49.6kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.86kg/m로 나타났다. 단층대 구간에서는 보통 포틀랜드시멘트의 평균주입량이 40.0kg/공이며, 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 2.75kg/m이며, 마이크로 시멘트는 평균주입량이 56.5kg/공, 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.15kg/m로 나타났다. 마이크로시멘트의 주입압은 보통 포틀랜드시멘트에 비해 상대적으로 낮았으며, 그라우팅 개선효과 역시 상대적으로 양호한 것으로 나타났다. 그라우팅 효과확인을 위한 물리검층의 초음파텔레뷰어 해석결과 상대암반강도는 주입전 $250{\sim}750\;kgf/cm^2$, 주입후는 $400{\sim}800\;kgf/cm^2$으로 그라우팅에 의한 암반강도의 상승을 확인할 수 있었고, 시추공영상촬영 분석에서는 시추코어만으로 얻기 힘든 시멘트 충진구간을 직접 확인할 수 있었다. 초음파텔레뷰어의 경우 파쇄대의 분포 및 암반강도 측정을 통한 그라우팅 파악은 가능하였으나 파쇄대 충진물을 확인할 수가 없는 단점이 있었고 이를 시추공영상촬영을 통해 보완할 수 있었다. 다만 물리검층의 경우 그라우팅에 의한 공의 손실로 동일공에 의한 반복 조사가 아닌 경우가 대부분이어서 그라우팅 효과에 대한 정확한 비교가 어려웠으며 추후 이를 보완하기 위한 계속적인 연구가 필요할 것으로 사료된다.

  • PDF

A Study on the Reinforcement Effect Analysis of Aging Reservoir using Grout Material recycled Power Plant Byproduct (발전부산물을 재활용한 그라우트재의 노후 저수지 보강효과 분석에 관한 연구)

  • Seo, Se-Gwan;An, Jong-Hwan;Cho, Dae-sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.2
    • /
    • pp.23-33
    • /
    • 2021
  • In Korea, many reservoirs have been built for the purpose of solving the food shortage problem and supplying agricultural water. However, the current 75.6% of the reservoirs are in serious aged as more than 50 years have passed since the year of construction. In the case of such an aging reservoir, the stability due to scour and erosion inside the reservoir is very reduced, and if concentrated rainfall due to recent abnormal weather occurs, the aging reservoir may collapse, leading to a lot of damage to property and human life. Accordingly, each agency that manages aging reservoirs uses Ordinary Portland Cement (OPC) as an injection material and applies the grouting method. However, in the case of OPC, it may deteriorate over time and water leakage may occur again. And there are environmental problems such as consumption of natural resources and generation of greenhouse gases. So, there is a need to develop new materials and methods that can replace the OPC. In this study, an laboratory test and analysis were performed on the grout material developed to induce a curing reaction similar to that of OPC by recycling power plant byproduct. In addition, test in the field such as electric resistivity survey, Standard Penetration Test (SPT), and field permeability test were performed to analyzed to reinforcement effect and determine the possibility of using instead of OPC. As a results of the test, in the case of recycled power plant byproduct, the compressive strength was 2.9 to 3.2 times and the deformation modulus was 2.3 to 3.3 times higher, indicating that it is excellent in strength and can be used instead of OPC. And it was analyzed that the N value of the reservoir was increased by 1~2, and the coefficient of permeability (k) decreased to the level of 8.9~42.5%. showing sufficient reinforcing effect in terms of order.