• Title/Summary/Keyword: initial values

Search Result 2,621, Processing Time 0.04 seconds

The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill;Kim, Seong-Kyun;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.76-80
    • /
    • 2011
  • PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

An Improvement on Estimation for Causal Models of Categorical Variables of Abilities and Task Performance

  • Kim, Sung-Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.1
    • /
    • pp.65-86
    • /
    • 2000
  • The estimates from an EM when it is applied to a large causal model of 10 or more categorical variables are often subject to the initial values for the estimates. This phenomenon becomes more serious as the model structure becomes more serious as the model structure becomes more complicated involving more variables. In this regard Wu(1983) recommends among others that EMs are implemented several times with different sets of initial values to obtain more appropriate estimates. in this paper a new approach for initial values is proposed. The main idea is that we use initials that are calibrated to data. A simulation result strongly indicates that the calibrated initials give rise to the estimates that are far closer to the true values than the initials that are not calibrated.

  • PDF

Improvement of the Transient Response by Partially Compensating Initial Values of Digital Controllers (디지털 제어기의 부분적 초기값 보상을 통한 천이 응답 특성 향상)

  • Doh, Tae-Yong;Ryoo, Jung Rae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.285-289
    • /
    • 2013
  • In switching from the track-seeking or track-jumping control mode to track-following control mode in hard disk drives or optical disk drives, initial values of the feedback controller are tuned to improve the transient response. In general, all the initial values of the controller have been compensated for this purpose. In this paper, by partially compensating initial values of digital controllers, we achieve a good performance of the transient response. In the proposed method for IVC (Intial Value Compensation), LMIs (Linear Matrix Inequalities) are used, which includes conditions for improving the performance of the transient response such as reducing a tracking error and control efforts. We obtain optimal initial values of the controller by solving an optimization problem with constraints represented by only one LMI. Although initial values of the controller are partially compensated, we can show that not only a sufficient performance of the transient response is obtained but also control efforts are diminished. The feasibility of the method is verified by simulation studies.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

The Initial Voiced Stops in Japanese (한국인 화자에 나타나는 일본어 어두 유성 자음의 경향 분석)

  • Kim, Seon-Hi
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.201-214
    • /
    • 2002
  • In the Japanese language, there is a phonological contrast between not only initial stops, but also non initial in voiced and voiceless sounds. But in the Korean language, voiced sounds do not appear in the initial. Due to this, pronunciation of voiced sounds in the initial will be difficult for Korean. Through this research, I analyzed the minimal pairs by voiced/voiceless sounds of Japanese and Korean, and perception experiment in which Japanese listened to Korean speakers' pronunciations. Japanese pronunciations showed distinct acoustic differences between voiced and voiceless stops, especially in VOT. The duration of vowels after voiced stops was longer than that of voiceless ones. Vowel pitches after voiceless stops were higher. On the other hands, Korean showed three patterns of voiced sounds. There were-VOT values as native speakers, +VOT, and nasal formant tended to occur before prenasalized stops. Koreans pronounced voiceless sounds in strong aspirated, unaspirated, or tense sounds. Finally, Japanese judged sounds with not only -VOT values and prenasalized, but also with +VOT values as voiced. This suggests that we may not consider VOT values as the unique feature of voicing, and that such other phonetic characteristics as the following vowel lengthening should be included here.

  • PDF

Initial value assumption for Estimation of Structural Dynamic System using Extended Kalman Filtering (구조물의 동특성치 예측을 위한 확장칼만필터기법의 초기치 설정에 관한 연구)

  • Jung, In-Hee;Yang, Won-Jik;Kang, Dae-Eon;Oh, Jong-Sig;Park, Hong-Shin;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.506-509
    • /
    • 2006
  • Extended Kalman Filter iterate the prediction and the filtering based on Initial state for the next time step. EKF method for the estimation of nonlinear parameters of a structural dynamic system is necessary that initial of state vector and error covariance matrix. Because those are unknown exactly, generally selected random values. That occasion observability problem appear because of unknown initial values. In this study, for the estimation of the nonlinear parameters, a simple one degree of Freedom example is carried out by Extended Kalman Filter. And initial value assumption for Parameter Estimation of Dynamic System are developed. The result of analysis is compared with calculated standard values.

  • PDF

Numerical method to determine the elastic curve of simply supported beams of variable cross-section

  • Biro, Istvan;Cveticanin, Livija;Szuchy, Peter
    • Structural Engineering and Mechanics
    • /
    • v.68 no.6
    • /
    • pp.713-720
    • /
    • 2018
  • In this paper a new numerical method to determine the elastic curve of the simply supported beams of variable cross-section is demonstrated. In general case it needs to solve linear or small nonlinear second order differential equations with prescribed boundary conditions. For numerical solution the initial values of the slope and the deflection of the end cross-section of the beam is necessary. For obtaining the initial values a lively procedure is developed: it is a special application of the shooting method because boundary value problems can be transformed into initial value problems. As a result of these transformations the initial values of the differential equations are obtained with high accuracy. Procedure is applied for calculating of elastic curve of a simply supported beam of variable cross-section. Results of these numerical procedures, analytical solution of the linearized version and finite element method are compared. It is proved that the suggested procedure yields technically accurate results.

A REGULARITY THEOREM FOR THE INITIAL TRACES OF THE SOLUTIONS OF THE HEAT EQUATION

  • Chung, Soon-Yeong
    • Journal of the Korean Mathematical Society
    • /
    • v.33 no.4
    • /
    • pp.1039-1046
    • /
    • 1996
  • In the theory of partial differential equations with given initial values and boundary values one usually investigates to examine the well-posedness, that is, the unique existence of the solution as well as its continuous dependence on the data. This theory is strong enough for us to determine the situation anywhere and anytime provided that the initial data are actually given. However, in many cases the data are not completely known for us. Then in those situations arise the new problem to determine the unknown initial data by taking other conditions for the solutions.

  • PDF

A Study on The Optimization Method of The Initial Weights in Single Layer Perceptron

  • Cho, Yong-Jun;Lee, Yong-Goo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.2
    • /
    • pp.331-337
    • /
    • 2004
  • In the analysis of massive volume data, a neural network model is a useful tool. To implement the Neural network model, it is important to select initial value. Since the initial values are generally used as random value in the neural network, the convergent performance and the prediction rate of model are not stable. To overcome the drawback a possible method use samples randomly selected from the whole data set. That is, coefficients estimated by logistic regression based on the samples are the initial values.

  • PDF

A Study on Consolidation Characteristics by Considering the Initial Radial Compression at Sand Pile Adjacent Ground (샌드파일 주변지반에서 초기 방사방향 압축에 의한 압밀특성 연구)

  • 천병식;여유현
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.649-656
    • /
    • 2000
  • Consolidation of the ground surrounding the sand piles is delayed by well resistance and smear effect. This study is executed to understand the factors that affect the characteristics of consolidation. This was accomplished by utilizing the estimated and measured values of the soil properties through the monitoring of the ground surrounding the sand piles. When it is assumed that the horizontal coefficient is equal to the vertical coefficient of consolidation, the estimated values is exceedingly similar to the measured values. The properties of the initially disturbed soil by the sand pile installation seemed to improve through the process of consolidation with the passage of time. From the results of the analysis of the settlement measurement, the measured values occurred about 60~90% of the predicted values. Considering the initial radical compression deformation, according to the theory of cavity expansion, the difference between the two appears to be in good agreement. In this study, to understand the behavioral characteristics of the ground surrounding the sand piles requires estimation through considering the initial radial compression as well as smear effect of the soil disturbance and well resistance.

  • PDF