• Title/Summary/Keyword: initial value method

Search Result 1,006, Processing Time 0.03 seconds

Long-Term Results for Repair of Pulmonary Atresia with Intact Ventricular Septum (온전한 심실중격를 가진 폐동맥 폐쇄증에 대한 수술적 치료의 장기 결과)

  • Lee Chang-Ha;Hwang Seong Wook;Lim Hong Gook;Kim Woong-Han;Kim Chong Whan;Lee Cheul
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.403-409
    • /
    • 2005
  • Pulmonary atresia with intact ventricular septum is morphologically heterogeneous, and the surgical outcome remains suboptimal compared to other complex congenital heart defects. We evaluated the long-term results for repair of pulmonary atresia with intact ventricular septum, Material and Method: Between January 1992 and June 2004, 38 patients underwent repair of pulmonary atresia with intact ventricular septum. The average age was 18 days $(2\~382\;days)$. The average Z-value of the tricuspid annulus diameter was -3.1$(-5.6\~0.8)$. Thirteen $(36\%)$ patients had right ventricle-to-coronary artery fistulas, and $4(11\%)$ patients had right ventricle-dependent coronary circulation. Average follow-up was 55 months $(3\;months\~2.2\;years)$, Result: Twenty-four patients under-went initial right ventricle (RV) decompression and 14 patients underwent systemic-to-pulmonary arterial shunt only. The average size of the tricuspid annulus of the patients who underwent RV decompression was significantly larger than that of the patients who underwent systemic-to-pulmonary arierial shunt only (Z-value -2.2 vs. -4.8, p=0.000). There were $5(13\%)$ early and 1 late deaths. Early deaths occurred in 3 patients who had undergone RV decompression, and in 2 patients who had undergone systemic-to-pulmonary arterial shunt only (p=1.0). Biventricular repair was achieved in $12(32\%)$ patients, single ventricular repair in $8(21\%)$, and one and a half ventricular repair in $4(l1\%)$ patients. Nine $(24\%)$ patients are waiting for the definitive repair. Kaplan-Meier survival at 5 and 8 years was $83.2\%$, respectively. Conclusion: Most of the deaths occurred after the initial palliation. Overall long-term survival was satisfactory. Early mortality should be reduced with careful preoperative evaluation and proper surgical strategy.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

DEGRADATION OF ACID SOLUBLE NUCLEOTIDES AND THEIR RELATED COMPOUNDS IN SEA FOODS DURING PROCESSING AND STORAGE 1. Changes of Nucleotides during Drying Process of the Anchovy, Engraulis japonica (수산식품의 가공 및 보장중의 핵산관련물질의 변화에 관한 연구 1. 마른 멸치 제조과정중의 핵산관련물질의 변화)

  • LEE Eung-Ho;PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.4 no.1
    • /
    • pp.31-41
    • /
    • 1971
  • The present study was directed to define the degradation pattern of the nucleotides and their related compounds in the muscle of anchovy during drying. Three kinds of samples, fresh, sun dried and boiled-and-dried anchovy, were prepared and the contents of nucleotides and related compounds of samples were determined by ion exchange chromatography. The results obtained are summarized as follows: Almost all of ATP disappeared in both muscle of sun dried and boiled-and-dried anchovy, although the initial content of ATP in fresh muscle was very low ($1.8{\mu}moles/g$, dry basis). But the remainning amount of ADP was considerably high while the other nucleotide almost entirely disappeared. This suggested that the residual ADP is responsible to the 'bound nucleotide' of myofibrils. In general, AMP content was comparatively lower than that of other nucleotides. Among three samples, the boiled-and-dried sample showed relatively higher AMP value than others. The amount of IMP remained in muscle remarkably varied between the boiled-and-dried anchovy and sun dried anchovy, the former's value being sixteen times higher than that of latter. In the contents of inosine and hypoxanthine, the sun dried anchovy marked an exceedingly high value equivalent to 2.7 times of the boiled-and-dried anchovy. In comparison of the ratio of inosine and hypoxanthine, hypoxanthine was accumulating in boiled-and-dried anchovy whereas inosine was in the sun-dried anchovy. Eighty three percent of total nucleotides in the fresh anchovy retained in the boiled-and-dried anchovy and IMP ratio in total nucleotides was $73\%$. On the contrary, the sun dried anchovy showed barely $10\%$ of retention rate and IMP ratio was only $38\%$. Considered from the flavor quality of dried anchovy, so far as concerned IMP content, it may be said that the boiled-and-drying method is more favorable process for dried product of anchovy than the sun-drying method.

  • PDF

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Electrochemical Behavior of Lithium-Iron Oxide Electrode and Measurement of Chemical Diffusion Coefficient of Lithium (리튬-철계 산화물 전극의 전기화학 거동 및 리튬의 화학확산 계수 측정)

  • Lee Joung-Jun;Chong Won-Jung;Ju Jeh-Beck;Sohn Tai-Won;Cho Won-Il;Cho Byung-Won;Kim Hyung-Sun
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.139-145
    • /
    • 2001
  • Various compositions of iron oxide based materials as a cathode of lithium secondary battery have been fabricated and tested with electrochemical method. A layered form of $LiFeO_2$ was synthesized by mixing and heating the initial materials of $FeCl_3\;6H_2O,\;LiOH$ and NaOH at low temperature. The effect of changing the precursors composition was investigated. As a result, when increasing the additive amount of NaOH, the capacity of the electrode is decreased but the performance and declining rate of capacity became smaller. $LiFeO_2$ synthesized with the weight ratio of $NaOH/FeCl_3/LiOH,\;2/1/7$ showed the largest capacity, but the discharging efficiency was sharply decreased after 30 cycles. Charge-discharge tests of lithium cells with $LiFeO_2$ cathode having the layer structure were performed. This cell showed the reversibility in the range of 1.5-4.5V of cell voltage. By using CPR method, chemical diffusion coefficients were measured in 1M $LiPF_6/EC/DEC$ solution. The value of chemical diffusion coefficient decreased with increasing the lithium content x, In 0.5$10^{-11}^cm^2/s$.

Effect of Temperature and Aging on the Relationship Between Dynamic and Static Elastic Modulus of Concrete (온도와 재령이 콘크리트의 동탄성계수와 정 탄성계수의 상관관계에 미치는 영향)

  • 한상훈;김진근;박우선;김동현
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.610-618
    • /
    • 2001
  • This paper investigates the relationships between dynamic elastic modulus and static elastic modulus or compressive strength according to curing temperature, aging, and cement type. Based on this investigation, the new model of the relationships we proposed. Impact echo method estimates the resonant frequency of specimens and uniaxial compression test measures the static elastic modulus and compressive strength. Type I and V cement concretes, which have the water-cement ratios of 0.40 and 0.50, are cured under the isothermal curing temperatures of 10, 23, and 50$\^{C}$ Cement type and aging have no large influence on the relationship between dynamic and static elastic modulus, but the ratio of dynamic and static elastic modulus comes close to 1 as temperature increases. Initial chord elastic modulus which is calculated at lower strain level of stress-strain curve, has the similar value to dynamic elastic modulus. The relationship between dynamic elastic modulus and compressive strength has the same tendency as the relationship between dynamic and static elastic modulus according to cement type, temperature and aging. The proposcd relationship equations between dynamic elastic modulus and static elastic modulus or compressive strength properly estimates the variation of relationships according to cement type md temperature.

Development of Simple Prediction Method for Injury Severity and Amount of Traumatic Hemorrhage via Analysis of the Correlation between Site of Pelvic Bone Fracture and Amount of Transfusion: Pelvic Bleeding Score (골반골절 환자의 골절위치와 출혈량간의 상관관계 분석을 통한 대량수혈 필요에 대한 간단한 예측도구 개발: 골반골 출혈 지수)

  • Lee, Sang Sik;Bae, Byung Kwan;Han, Sang Kyoon;Park, Sung Wook;Ryu, Ji Ho;Jeong, Jin Woo;Yeom, Seok Ran
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.139-144
    • /
    • 2012
  • Purpose: Hypovolemic shock is the leading cause of death in multiple trauma patients with pelvic bone fracures. The purpose of this study was to develop a simple prediction method for injury severity and amount of hemorrhage via an analysis of the correlation between the site of pelvic bone fracture and the amount of transfusion and to verify the usefulness of the such a simple scoring system. Methods: We analyzed retrospectively the medical records and radiologic examination of 102 patients who had been diagnosed as having a pelvic bone fracture and who had visited the Emergency Department between January 2007 and December 2011. Fracture sites in the pelvis were confirmed and re-classified anatomically as pubis, ilium or sacrum. A multiple linear regression analysis was performed on the amount of transfusion, and a simplified scoring system was developed. The predictive value of the amount of transfusion for the scoring system as verified by using the receiver operating characteristics (ROC). The area under the curve of the ROC was compared with the injury severity score (ISS). Results: From among the 102 patients, 97 patients (M:F=68:29, mean $age=46.7{\pm}16.6years$) were enrolled for analysis. The average ISS of the patients was $16.2{\pm}7.9$, and the average amount of packed RBC transfusion for 24 hr was $3.9{\pm}4.6units$. The regression equation resulting from the multiple linear regression analysis was 'packed RBC units=1.40${\times}$(sacrum fracture)+1.72${\times}$(pubis fracture)+1.67${\times}$(ilium fracture)+0.36' and was found to be suitable (p=0.005). We simplified the regression equation to 'Pelvic Bleeding Score=sacrum+pubis+ilium.' Each fractured site was scored as 0(no fracture) point, 1(right or left) point, or 2(both) points. Sacrum had only 0 or 1 point. The score ranged from 0 to 5. The area under the curve (AUC) of the ROC was 0.718 (95% CI: 0.588-0.848, p=0.009). For an upper Pelvis Bleeding Score of 3 points, the sensitivity of the prediction for a massive transfusion was 71.4%, and the specificity was 69.9%. Conclusion: We developed a simplified scoring system for the anatomical fracture sites in the pelvis to predict the requirement for a transfusion (Pelvis Bleeding Score (PBS)). The PBS, compared with the ISS, is considered a useful predictor of the need for a transfusion during initial management.

Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion (혐기성 소화의 후처리로서 분리막의 여과특성 연구)

  • Choo, Kwang-Ho;Lee, Chung-Hak;Pek, Un-Hwa;Koh, Ui-Chan;Kim, Sang-Won;Koh, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.730-738
    • /
    • 1992
  • Filtration characteristics according to membrane materials were studied In the ultrafiltration of anaerobic digestion broth as a post treatment method. A series of resistances for different membranes were quantitatively assessed on the basis of the resistance-in-series model. Flux behavior observed with the digestion broth was irrelevant to initial water permeabilities of each membrane. The fluoro polymer membrane showed the most significant improvement of flux with increase of cross-flow velocity, which suggests that the cake layer formed on this membrane is more weakly attached to the membrane surface than those on the other membranes. Flux reduction during longtime running was attrib-used to the polarization layer resistance ($R_p$) as well as the fouling layer resistance($R_f$). Continuous increase of $R_p$ may reflect the variation in the characteristics of cake layers, which could result from size, shape, and structure changes due to lysis and growth of biomass. Hydrophilic cellulosic membrane had a much lower fouling tendency than hydrophobic polysulfone membrane. The depressurization method induced a small increase in flux of $5-10L/m^2/h$. During washing and cleaning, filtrability of each membrane was rapidly recovered within 15 minutes until a stationary value was reached.

  • PDF

Fire Resistance Performance of High Strength Concrete with 4 Deformation Factors (4변형 인자에 의한 고강도콘크리트의 내화성능 평가)

  • Lee, Tae Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.112-120
    • /
    • 2012
  • A numerical model considering the internal vaporization and the creep effect, in the form of a analytical program, for tracing the behavior of high strength concrete(HSC) members exposed to fire is presented. The two stages, i.e., spalling procedure and fire resistance time, associated with the thermal, moisture flow, creep and structural analysis, for the prediction of fire resistance behavior are explained. The use of the analytical program for tracing the response of HSC member from the initial pre-loading stage to collapse, due to fire, is demonstrated. Moisture evaporates, when concrete is exposed to fire, not only at concrete surface but also at inside the concrete to adjust the equilibrium and transfer properties of moisture. Finite element method is employed to facilitate the moisture diffusion analysis for any position of member, so that the prediction method of the moisture distribution inside the concrete members at fire is developed. The validity of the numerical model used in this program is established by comparing the predictions from this program with results from others fire resistance tests. The analytical program can be used to predict the fire resistance of HSC members for any value of the significant parameters, such as load, sectional dimensions, member length, and concrete strength.

Improvement of DS Simple Reception System for Advance of Duty Rate on Meteor Burst Transmission Path (유성 버스트 전송로의 도통을 향상을 위한 DS 간이 수신시스템의 개선)

  • Kwon Hyeog-Soong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1073-1080
    • /
    • 2005
  • In spite of many advantages of Meteor Burst Communications(MBC) on its transmission channel, the fact that its duty rate is less than 10 percents is a considerable deficiency of MBC. To overcome with this deficiency without paying large cost, we use a direct sequence(DS) simple reception system. This method doesn't need to add the components for acquisition or tracking the signal so that it keeps the cost efficiency of the MBC. But it has a disadvantage that its duty rate shows a large decline by noise. For this problem, we adopt the proposed system applying a positive feedback circuit. The improvement by this method is more significant when the received signal is weak. Simulation results show as tl is l00ms, then the burst length would be increased by $35\%$ when the initial value of the received signal power increases by 3 dB, t2 is 135ms. If the power increases by 6dB the burst length would be 170ms thus increased by $70\%$, which shows a great enhancement. Suppose now that tl is 50ms and the power is increased by 3dB, then t2 would be increased by $70\%$ to 85ms, and increasing the power by 6dB it would be increased by $130\%$ to 115ms.