• Title/Summary/Keyword: initial stress

Search Result 1,858, Processing Time 0.027 seconds

Selection of Tolerant Plant Species using Pot Culture for Remediation of Explosive Compounds Contaminated Soil (포트 재배에 의한 화약물질 오염토양 정화용 내오염성 식물 선정)

  • Lee, Ahreum;Bae, Bumhan
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.73-84
    • /
    • 2015
  • Nine plant species were selected through vegetation survey at three military shooting ranges at northern Gyeonggi Province. Plants were germinated in normal soil and three seedlings were transplanted to a bottom sealed pot containing sandy loam soils contaminated with either RDX (291 mg/kg) or TNT (207 mg/kg). Planted, blank (without plant), and control (without explosive compound) pots were grown in triplicate at a green house for 134 days. During cultivation, transplanted plants exhibited chlorosis and necrosis in flower and leaf by explosive toxicity and stress. Only three plants, Wild soybean, Amur silver grass, Reed canary grass, survived in TNT treated pot, while seven plant species except for field penny cress and jimson weed, thrived in RDX treated pot. Appreciable amount of TNT (61.6~241.2 mg/g-D.W.) was detected only in plant roots. Up to 763.3 mg/g-D.W. along with 4-amino-2,6-dinitrotoluene, an intermediate of TNT, accumulated in the root of wild soybean. In addition, azoxy compounds, abiotic intermediates of TNT, were detected in TNT treated soils. RDX absorbed average 1,839.95 mg/kg in shoot and 204.83 mg/kg in root. Most of TNT in plant was accumulated in underground part whereas RDX was localized in aerial part. Material balance calculation showed that more than 95% of the initial TNT was removed in the planted pots whereas only 60% was removed in the blank pot. The amount of RDX removed from soil was in the order of Amur Silver Grass (51%) > Chickweed (43%) > Evening primrose (38%). Based on the results of pot cultures, Amur silver grass and Reed canary grass are selected as tolerant remedial plants for explosive toxicity.

Primary Tissue Filure of Bioprosthetic Valves (생물학적 보철판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.667-676
    • /
    • 1993
  • Boprosthetic cardiac valves fail from biological and metabolic as well as mechanical reasons, and the limited durability is the main factor of marked withdrawal in their clinical use. Starting the use of bioprosthetic valves in 1976, up to the end of 1992, the consecutive 178 patients have undergone re-replacement of glutaraldehyde-treated xenograft valves for primary tissue failure [PTF]among the patients who had initial valve replacement at Seoul national University Hospital. The explanted valves were 69 porcine aortic [51 Hancock, 12 Angell-Shiley and 6 Carentier-Edwards] and 141 bovine pericardial [129 standard-profile and 12 low-profile ionescu-Shiley] valwes, with an overall incidence of PTF of 15.2%. The operative mortality rate of re-replacement was 5.1%. Calcific degeneration and tissue damage in relation to calcification were the most frequent modes of PTF on gross examinatin of the explanted valves resulting hemodynamically in valvular regurgitation. The number of Hancocg porcine and the standard-profile Ionescu-Shiley valves in valves in mitral position failed more often from tissue damage [tears, holes, and loss or destruction of cuspal tissue] than calcification [68.3% vs. 39.0%, p<0.01] with resultant regurgitation in 61%, the Ionescu-Shiley valves in the same position in 53%. The tendency of more calcification than tissue damage[71.3% vs. 33.3%, p<0.001]with stenosis in 53%. The tendency of more calcification and immobility of cusps in the latter group was partly explainable by the inclusion of patients of pediatric age. Observation made in this study suggest : many of bioprosthetic valves would fail from calcification and tissue damage : some fail prematurely because of mechanical stress probably owing to the valve design in construction ; andeven those valves escaped early damage would be subject to calcify in the prolonged follow-up period. In conclusion, at the present time, the clinical use of bioprostheticxenograft valves seems to be quite limited until further improvement in biocompatibility and refinement in valve design in manufacture are achieved.

  • PDF

Effects of Hardeners on the Low-Temperature Snap Cure Behaviors of Epoxy Adhesives for Flip Chip Bonding (플립칩용 에폭시 접착제의 저온 속경화 거동에 미치는 경화제의 영향)

  • Choi, Won-Jung;Yoo, Se-Hoon;Lee, Hyo-Soo;Kim, Mok-Soon;Kim, Jun-Ki
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.454-458
    • /
    • 2012
  • Various adhesive materials are used in flip chip packaging for electrical interconnection and structural reinforcement. In cases of COF(chip on film) packages, low temperature bonding adhesive is currently needed for the utilization of low thermal resistance substrate films, such as PEN(polyethylene naphthalate) and PET(polyethylene terephthalate). In this study, the effects of anhydride and dihydrazide hardeners on the low-temperature snap cure behavior of epoxy based non-conductive pastes(NCPs) were investigated to reduce flip chip bonding temperature. Dynamic DSC(differential scanning calorimetry) and isothermal DEA(dielectric analysis) results showed that the curing rate of MHHPA(hexahydro-4-methylphthalic anhydride) at $160^{\circ}C$ was faster than that of ADH(adipic dihydrazide) when considering the onset and peak curing temperatures. In a die shear test performed after flip chip bonding, however, ADH-containing formulations indicated faster trends in reaching saturated bond strength values due to the post curing effect. More enhanced HAST(highly accelerated stress test) reliability could be achieved in an assembly having a higher initial bond strength and, thus, MHHPA is considered to be a more effective hardener than ADH for low temperature snap cure NCPs.

Spark Plasma Sintering and Ultra-Precision Machining Characteristics of SiC

  • Son, Hyeon-Taek;Kim, Dae-Guen;Park, Soon-Sub;Lee, Jong-Hyeon
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.559-569
    • /
    • 2010
  • The liquid-phase sintering method was used to prepare a glass lens forming core composed of SiC-$Al_2O_3-Y_2O_3$. Spark plasma sintering was used to obtain dense sintered bodies. The sintering characteristics of different SiC sources and compositions of additives were studied. Results revealed that, owing to its initial larger surface area, $\alpha$-SiC offers sinterability that is superior to that of $\beta$-SiC. A maximum density of $3.32\;g/cm^3$ (theoretical density [TD] of 99.7%) was obtained in $\alpha$-SiC-10 wt% ($6Al_2O_3-4Y_2O_3$) sintered at $1850^{\circ}C$ without high-energy ball milling. The maximum hardness and compression stress of the sintered body reached 2870 Hv and 1110 MPa, respectively. The optimum ultra-precision machining parameters were a grinding speed of 1243 m/min, work spindle rotation rate of 100 rpm, feed rate of 0.5 mm/min, and depth of cut of $0.2\;{\mu}m$. The surface roughnesses of the thus prepared final products were Ra = 4.3 nm and Rt = 55.3 nm for the aspheric lens forming core and Ra = 4.4 nm and Rt = 41.9 for the spherical lens forming core. These values were found to be sufficiently low, and the cores showed good compatibility between SiC and the diamond-like carbon (DLC) coating material. Thus, these glass lens forming cores have great potential for application in the lens industry.

Thermal, Mechanical, and Electrical Properties of Fluorine-Containing Epoxy Resins (불소함유 에폭시 수지의 열적, 기계적 및 전기적 특성)

  • 박수진;김범용;이재락;신재섭
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.183-188
    • /
    • 2003
  • The dielectric constants of fluorine-containing epoxy resins, 2-diglycidylether of benzotrifluoride(FER)/4,4'-diamino-diphenyl methane (DDM) and diglycidylether of bisphenol-A (DGEBA)/DDM systems were evaluated by dielectric spectrometer. Glass transition temperature and thermal stability factors, including initial decomposed temperature, temperatures of maximum rate of degradation, and decomposition activation energy of the cured specimens were investigated by dynamic mechanical analysis and thermogravimetric analysis. For the mechanical properties of the casting specimens, the fracture toughness, flexural, and impact tests were performed, and their fractured surfaces were examined by scanning electron microscope. The dielectric constant of FER/DDM system was lower than that of commercial DGEBA/DDM system, and the mechanical properties of the cured specimens showed higher values than those of DGEBA/DDM system. This was probably due to the introduction of trifluoromethyl (CF$_3$) group into the side chain of the epoxy resins, resulting in improving the electric and mechanical properties of the epoxy cure system studied.

The physical properties and the dyeability of the easily dyeable polyester yarn under atmospheric pressure (상압가염형 폴리에스테르 섬유의 물성과 염색성)

  • Kim, Tae Gyeong;Yun, Seok Han;Sin, Sang Yeop;Im, Yong Jin;Jo, Gyu Min
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.33-33
    • /
    • 2001
  • The physical properties and the dyeability of the easily dyeable polyester yarn(EDY) were investigated and compared with those of regular polyester (REG-PET). The EDY, copolymerized with small amount of polyethylene glycol(PEG), showed higher intensity of aliphatic CH peak in IR spectrum, lower density and lower compactness than those of the REG-PET from the analysis of IR, density gradient column and XRD respectively. In the physical properties, the EDY has lowers $T_g,\;T_m$, specific stress and initial modulus, and also has higher strain than that of the REG-PET. The EDY can be dyed under atmospheric pressure and its dyeing rate was faster than REG-PET due to low $T_d$, and this seems to be caused by the increased flexibility of Polymer chain in amorphous region of the EDY due to the copolymerization of PEG.ns being within the experimental error, the average values of lifetim. $\tau$(t) are taken for further calculations. Rate constants such as Stern-Volmer quenching constants K$_{sv}$, quenching rate parameters k$_q$ and k''$_q$, static quenching constant V and kinetic distance r are determined using the modified Stern-Volmer eq.tion and sphere of action static quenching model. In order to see whether the reactions are diffusion limited, equations k$_q$ = e$^{-Eq/RT}$ and k''$_q$ = e$^{-Eq/RT}$ are used to determine the values of E$_q$ and E''$_q$, the activati. energies for collisional quenching and the values of E$_q$ are 14.53, 17.28 and 16.20 kJ mole$^{-1}$ for MPNO1, MPNO2 and 2-PI respectively and the values of E''$_q$ are 14.62 and 17.73 for MPNO1 and MPNO2 respectively. From the magnitudes of various quantities it has.een concluded that the reactions are diffusion limited and the observed positive deviations in the S-V plot are due to static and dynamic quenching.

Biological Phosphorus and Nitrogen Removal in Anaerobic-Aerobic Activated Sludge Process (활성오니를 이용한 인 및 질소의 생물학적 제거)

  • CHOI Seung-Tae;PARK Mi-Yeon;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.6
    • /
    • pp.690-695
    • /
    • 1994
  • Simultaneous removal of phosphorus and nitrogen from wastewater was studied by the anaerobic-aerobic system of activated sludge. In the anaerobic stage, most of the influent glucose was removed and orthophosphate was released, when the nitrate and/or nitrite concentration in the wastewater was almost zero. The amount of the released phosphorus was found to be directly proportional to the amount of the removed glucose. When the ratio of phosphorus to glucose in the influent was less than 0.04, the phosphorus in the wastewater was almost completely removed during the aerobic state. Under the anaerobic condition, activated sludge released phosphate and excess removal of phosphate occurred during the aerobic condition. Namely, the stress received in anaerobic period stimulated the uptake of phosphorus in aerobic period. The amounts of phosphorus release in the anaerobic and uptake in the aerobic stage were less in proportional to the concentration of $NO_x-N$. Further, if the initial ratio of $NO_2-N$/glucose was less than 0.37, the inorganic nitrogen in the influent could be completely removed.

  • PDF

Vascularized Fibular Graft in the Treatment of Bone Tumor (혈관부착 생비골 이식술을 이용한 골종양의 치료)

  • Han, Chung-Soo;Yoo, Myung-Chul;Chung, Duke-Whan;Lee, Geon-Hee;Lee, Chong-Won
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 1995
  • Recently vascularized fibular transfer has been used in the treatment of bone tumor that are more than six centimeter in length. With refinements in microsurgical techniques and understanding of the biological and biomechanical characteristics of vascularized bone graft, the success rate of this procedure was increased. Fifteen bone tumor patients, sixteen cases seen from Apr. 1979 to Jun. 1995 were managed by means of vascularized bone graft at Kyung Hee University Hospital. Ten cases were done intercalary graft and the others were done osteoarticular graft. the ratio of male and female was 6 : 9, and mean age was 20.4 years old at operation. Mean follow up period was 5 years 4 months(range 17 months to 16 years 2 months) and mean graft length was 13.8cm. Duration for union was 5.3 months(range 3 months to 1 year) and over-all rate of union at the last follow up examination was 93.8%. Sufficient hypertrophy of grafted bone was obtained in all cases at the time of last follow up as compared to initial size of grafted bone. Several complications were found such as stress fractures, recurrence. Vascularized fibular transfer for the treatment of bone tumor is a valuable procedure in appropriately selected patients.

  • PDF

Finite Element Analysis on Heat of Hydration with Reinforcing Steel Bars (철근의 영향을 고려한 수화열 유한요소해석)

  • Yoon Dong-Yong;Yang Ok-Bin;Min Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.43-49
    • /
    • 2005
  • In the concrete structures, the magnitude and distribution of the temperature due to the heat of hydration are related to the thermal properties of each component composed of the concrete, the initial temperature, the type of formwork, and the ambient temperature of exposed surfaces. Even though the reinforcing steel bar has completely different thermal properties, it has been excluded. In the thermal analysis on the concrete structures. In this study, finite element analysis was performed on the concrete structures including the reinforcing steel in order to investigate their effect on temperature and stress distribution due to the heat of hydration. As the steel ratio increased, the maximum temperature and the internal-external temperature difference decreased by 32.5% and 10%, respectively. It is clear that the inclusion of reinforcing steel bars on the heat of hydration analysis is indispensable to obtain realistic solutions for the prediction of the maximum temperature and stresses

Flexural Behaviors of Precast Prestressed Rectangular and Inverted-tee Concrete Beams for Buildings

  • Yu, Sung-Yong
    • KCI Concrete Journal
    • /
    • v.14 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • Flexural behaviors of the two typical precast beam sections (inverted tee and rectangular) for buildings were investigated and compared. The height of web in the inverted tee beam was generally less than half of beam depth to be adapted to that of the nib in the ends of double-tee where the total building height limited considerably. The inverted-tee beams were designed for a parking live load - 500kgf/$m^2$ and a market - 1,200kgf/$m^2$ from the currently used typical shape of a domestic building site in Korea. The area and bottom dimension of rectangular beams were the same as those of inverted tee beams. These woo beams were also reinforced with a similar strength. following results were obtained from the studies above; 1) the rectangular beam is simpler in production, transportation, and erection, and more economic than the inverted tee beam in the construction test for these two beams with a same dimension and a similar strength, 2) all of the beams considered in the tests were generally failed in values close to those of the strength requirements in ACI Provisions. The ratios of test result to calculated value are averaged to 1.04. One rectangular and one inverted tee beams failed in a value only 2-3% larger than the estimated volue of the Strength Design Methool the results of the Strain Compatibility Method wire slightly more accurate than those of the Strength Design Method, 4) the maximum deflections of all of the beams under the full service loads were less than those of the allowable limit in ACI Code Provisions. The rectangular beams experienced more deflection then inverted tee in the same loading condition and failed with more deflection, and 5) the rectangular and inverted tee beams showed good performances under the condition of service and ultimate loads. However, one inverted tee beams with fm span developed an initial flexural crackings under 88% of the full service load even though they designed to satisfy the ACI tensile stress limit provisions.

  • PDF