• Title/Summary/Keyword: initial shape

Search Result 1,454, Processing Time 0.035 seconds

Processing of Water Activity Controlled Fish Meat Paste by Dielectric Heating 1. Formulation and Processing Conditions (내부가열을 이용한 보장성어육(고등어) 연제품의 가공 및 제품개발에 관한 연구 1. 원료${\cdot}$첨가물의 배합 및 가공조건)

  • LEE Kang-Ho;LEE Byeong-Ho;You Byeong-Jin;SUH Jae-Soo;JO Jin-Ho;JEONG In-Hak;JEA Yoi-Guan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.353-360
    • /
    • 1984
  • As an effort to expand the utilization of mackerel which has been thought disadvantageous to processors due to the defects in bloody dark color of meat, high content of lipid, and low stability of protein, and to develope a new type of product, so called, preservative fish meat paste, the processing method was studied in which dielectric heating was applied by means of cooking, pasteurization, dehydration, and control of water activity. The principle of this method is based on that dielectric heating can initiate a rapid dispersion or displacement of moisture in the meat tissue so that the level of water acivity can be controlled by dehydration with hot air meanwhile the product is cooked, pasteurized, and texturized. And the product is finally heated with electric heaters and vacuum sealed to stabilize water activity and storage stability. In present paper, a formula for preparing the fish meat-stach paste, the conditions of dielectric heating and dehydration, shape and size of the product, and other parameters were tested to optimize the process operation. A formula of the fish meat-starch paste to provide proper textural properties and water activity was $10\%$ starch, $1.5\%$ salt, $3\%$ soybean, $0.6\%$ MSG, $2\%$ sucrose, and $3\%$ sorbitol against the weight of fish meat. A proper shape and size of the product to avoid foaming and case hardening during heating was sliced disc of 8 cm $diameter{\times}0.8$ cm thickness or $10{\times}10$ cm square plate with 1.0 cm thickness. The disc shape was recommended because it resulted more uniform heating, minimum foaming and case hardening. And it was also advantageous that disc was simply provided when the fish meat disc was stuffed in the same, solidified in boiling water for 2 to 3 minutes, and sliced. Condition of dielectric heating was critical to decide the levels of sterility, water activity, and textural property of the product. The temperature at the center of the meat disc slices was raised up to $95^{\circ}C$ in 1.5 minutes so that continuous exposure to microwave caused expanded tissue and hardening ending up with a higher water content. Heating for 5 to 6 minutes was adequate to yield the final water activity of 0.86 to 0.83(35 to $40\%$ moisture). It is important, however, that heating had to be done periodically, for instance, in the manner of 2.0, 1.5, 1.5, and 1.0 minute to give enough time to displace or evaporate moisture from the meat tissue. The product was dehydrated for 2 to 3 minutes by hot air of $60^{\circ}C$, 3 to 5m/sec and finally exposed to electric heaters for 5 to 6 minutes until the surface was roasted deep brown. These conditions of heating and dehydration resulted in a complete reduction of total plate count from an initial count of $5.3{\times}10^6/g$ to less than $3{\times}10^2/g$. General composition of the product was $40.1\%$ moisture, $20.8\%$ protein, $17.4\%$ lipid, $16.2\%$ carbohydrate, and $5.5\%$ ash. Textural properties revealed folding test AA, hardness 42, cohesiveness 0.53, toughness 4.6, and elasticity 0.8.

  • PDF

THE EFFECTS OF THERMAL STIMULI TO THE FILLED TOOTH STRUCTURE (온도자극이 충전된 치질에 미치는 영향)

  • Baik, Byeong-Ju;Roh, Yong-Kwan;Lee, Young-Su;Yang, Jeong-Suk;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.339-349
    • /
    • 1999
  • The dental structure substituted by restorative materials may produce discomfort resulting from hot or cold stimuli. To investigate the effects of this stimuli on the human teeth, thermal analysis was carried out by calculation of general heat conduction equation in a modeled tooth using numerical method. The method has been applied to axisymmetric and two-dimensional model, analyzing the effects of constant temperature $4^{\circ}C\;and\;60^{\circ}C$. That thermal shock was provided for 2 seconds and 4 seconds, respectively and recovered to normal condition of $20^{\circ}C$ until 10 seconds. The thermal behavior of tooth covered with a crown of gold or stainless steel was compared with that of tooth without crown. At the same time, the effects of restorative materials(amalgam, gold and zinc oxide-eugenol(ZOE)) on the temperature of PDJ(pulpo-dentinal junction) has been studied. The geometry used for thermal analysis so far has been limited to two-dimensional as well as axisymmetric tooth models. But the general restorative tooth forms a cross shaped cavity which is no longer two-dimensional and axisymmetric. Therefore, in this study, the three-dimensional model was developed to investigate the effect of shape and size of cavity. This three-dimensional model might be used for further research to investigate the effects of restorative materials and cavity design on the thermal behavior of the real shaped tooth. The results were as follows; 1. When cold temperature of $4^{\circ}C$ was applied to the surface of the restored teeth with amalgam for 2 seconds and recovered to ambient temperature of $20^{\circ}C$, the PDJ temperature decreased rapidly to $29^{\circ}C$ until 3 seconds and reached to $25^{\circ}C$ after 9 seconds. This temperature decreased rather slowly with stainless steel crown, but kept similar temperature within $1^{\circ}C$ differences. Using the gold as a restorative material, the PDJ temperature decreased very fast due to the high thermal conductivity and reached near to $25^{\circ}C$ but the temperature after 9 seconds was similar to that in the teeth without crown. The effects of coldness could be attenuated with the ZOE situated under the cavity. The low thermal conductivity caused a delay in temperature decrease and keeps $4^{\circ}C$ higher than the temperature of other conditions after 9 seconds. 2. The elapse time of cold stimuli was increased also until 4 seconds and recovered to $20^{\circ}C$ after 4 seconds to 9 seconds. The temperature after 9 seconds was about $2-3^{\circ}C$ lower than the temperature of 2 seconds stimuli, but in case of gold restoration, the high thermal conductivity of gold caused the minimum temperature of $21^{\circ}C$ after 5 seconds and got warm to $23^{\circ}C$ after 9 seconds. 3. The effects of hot stimuli was also investigated with the temperature of $60^{\circ}C$. For 2 seconds stimuli, the temperature increased to $40^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 3 seconds of stimuli and decreased to $30^{\circ}C$ after 9 seconds in the teeth without crown. This temperature was sensitive to surface temperature in the teeth with gold restoration. It increased rapidly to $41^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 2 seconds and decreased to $28^{\circ}C$ after 9 seconds, which showed $13^{\circ}C$ temperature variations for 9 seconds upon the surface temperature. This temperature variations were only in the range of $5^{\circ}C$ by using ZOE in the bottom of cavity and showed maximum temperature of $37^{\circ}C$ after 3 seconds of stimuli.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

A Study on Movement of the Free Face During Bench Blasting (전방 자유면의 암반 이동에 관한 연구)

  • Lee, Ki-Keun;Kim, Gab-Soo;Yang, Kuk-Jung;Kang, Dae-Woo;Hur, Won-Ho
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.29-42
    • /
    • 2012
  • Variables influencing the free face movement due to rock blasting include the physical and mechanical properties, in particular the discontinuity characteristics, explosive type, charge weight, burden, blast-hole spacing, delay time between blast-holes or rows, stemming conditions. These variables also affects the blast vibration, air blast and size of fragmentation. For the design of surface blasting, the priority is given to the safety of nearby buildings. Therefore, blast vibration has to be controlled by analyzing the free face movement at the surface blasting sites and also blasting operation needs to be optimized to improve the fragmentation size. High-speed digital image analysis enables the analyses of the initial movement of free face of rock, stemming optimality, fragment trajectory, face movement direction and velocity as well as the optimal detonator initiation system. Even though The high-speed image analysis technique has been widely used in foreign countries, its applications can hardly be found in Korea. This thesis aims at carrying out a fundamental study for optimizing the blast design and evaluation using the high-speed digital image analysis. A series of experimentation were performed at two large surface blasting sites with the rock type of shale and granite, respectively. Emulsion and ANFO were the explosives used for the study. Based on the digital images analysis, displacement and velocity of the free face were scrutinized along with the analysis fragment size distribution. In addition, AUTODYN, 2-D FEM model, was applied to simulate detonation pressure, detonation velocity, response time for the initiation of the free face movement and face movement shape. The result show that regardless of the rock type, due to the displacement and the movement velocity have the maximum near the center of charged section the free face becomes curved like a bow. Compared with ANFO, the cases with Emulsion result in larger detonation pressure and velocity and faster reaction for the displacement initiation.

The Effect of Fly Ash Composition and Reaction Conditions on Hydrothermal Synthesis of Zeolitic Materials (Fly ash 조성(組成)과 반응조건(反應條件)이 zeolite성(性) 물질(物質)의 열수합성(熱水合成)에 미치는 영향(影響))

  • Choi, Choong-Lyeal;Lee, Dong-Hoon;Park, Man;Choi, Jyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • This study was performed to examine the effect of initial composition ratio and various reaction conditions on CEC and crystallinity of the product in hydrothermal synthesis of zeolitic materials from fly ash. Na-P1 zeolite was formed from the mixture with $SiO_2/Al_2O_3$ ratio above 2.55, however from the mixture with $SiO_2/Al_2O_3$ ratio below 2.25 hydroxy sodalite was formed. The CEC of reaction product(Na-P1 zeolite) treated with 3N-NaOH, $Na_2O/Al_2O_3$ ratio 2.55 and $SiO_2/Al_2O_3$ ratio 2.0 for 12 hours at $103^{\circ}C$ was about $285cmol^+kg^{-1}$, which was higher than those of the products of other reaction condition. The crystallinity of Na-P1 zeolite as high as 45.1% was attained at the optimum reaction condition of 2N-NaOH, $SiO_2/Al_2O_3$ ratio 2.55, $Na_2O/Al_2O_3$ ratio 1.5 for 12 hours at $103^{\circ}C$. The XRD peak of the reaction product could be measured at 7.16, 5.04, 4.12, 3.18, $2.69{\AA}$ and tetragonal pillar shape observed by SEM image be characteristic for Na-P1 zeolite. Judging from the result, it should be considered the optimum synthesis condition for Na-P1 zeolite from fly ash was 2~3N NaOH, $SiO_2/Al_2O_3$ ratio 2.55 and $Na_2O/Al_2O_3$ ratio 1.5~2.0 for 12 hours at $80{\sim}103^{\circ}C$.

  • PDF

A study on the synthesis of lanthanum oxide (La2O3) from NaLa(SO4)2·H2O by metathesis reaction (NaLa(SO4)2·H2O 결정상으로부터 이온치환반응에 의한 산화란탄 (La2O3) 분말 합성에 관한 연구)

  • Kim, Dae-Weon;Ahn, Nak-Kyoon;Shim, Hyun-Woo;Lee, Chan-Gi;Choi, Hee-Lack;Hong, Hyun Seon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.5
    • /
    • pp.211-216
    • /
    • 2018
  • The recovery of rare earth elements (REE) including La, Nd and Ce from spent batteries is important issues to reuse scarce resources. Herein, we present a simple recovery process to obtain lanthanum oxide ($La_2O_3$) from spent Ni-MH batteries, and demonstrate the conversion mechanism from $NaLa(SO_4)_2{\cdot}H_2O$ to $La_2O_3$. This strategy requires the initial preparation of $NaLa(SO_4)_2{\cdot}H_2O$ and subsequent metathesis reaction with $Na_2CO_3$ at $70^{\circ}C$. This metathesis reaction resulted in the crystalline lanthanum carbonate hydrate ($La_2(CO_3)_3{\cdot}xH_2O$) powder with plate-like morphology. On the basis of TGA result, the $La_2(CO_3)_3{\cdot}xH_2O$ powder was calcined in air at three different temperatures, that is, $300^{\circ}C$, $500^{\circ}C$, and $1000^{\circ}C$. As the calcination temperature increased, the morphology of powder was changed; prism-like ($NaLa(SO_4)_2{\cdot}H_2O$) ${\rightarrow}$ platelike ($La_2(CO_3)_3{\cdot}xH_2O$) ${\rightarrow}$ aggregated irregular shape ($La_2O_3$). Futhermore, XRD results indicated that the crystalline $La_2O_3$ could be synthesized after the metathesis reaction with $Na_2CO_3$, followed by heat-treatment at $1000^{\circ}C$, along with a change of crystallographic structures; $NaLa(SO_4)_2{\cdot}H_2O$ ${\rightarrow}$ $La_2(CO_3)_3{\cdot}xH_2O$ ${\rightarrow}$ $La_2O_3$.

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Net Shapes of the Model Pound net according to Added Sinker - In case of the upperward flow with fish court net - (부가중량추에 따른 모형 정치망의 형상변화 - 운동장이 湖上側인 경우 -)

  • Yun, Il-Bu;Lee, Ju-Hee;Kwon, Byeong-Guk;Yoo, Jae-Bum;Cho, Young-Bok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.17-26
    • /
    • 2005
  • There are several problems in the commercial pound net in the heavy tide ; the breaking and loss of net, steeply variation of net shape and decreasing of fishing efficiency, etc. In order to solve these problems, we introduced method of added sinker used to coastal cultivating cage of Japan and investigated the possibility of application to the Korean pound net. The results are obtained as follows; 1. In case of the upperward flow with fish court net, tension of the frame line was increased about 10${\sim}$25% than that of prototype according to the added sinker from 1.3gf to 5.2gf. The tension of A-type and B-type was similar to the case of the prototype, the tension of C-type and D-type was increased about 10${\sim}$15% than that of prototype. 2. The variation of deformed angle of fish court net was from 0$^{\circ}$ to 70$^{\circ}$ and that of the slope net was from 0$^{\circ}$ to 64$^{\circ}$ and that of the second bag net was from 0$^{\circ}$ to 46$^{\circ}$ and the depth of the second bag net was increased about 10% when the added sinker was changed from 1.3gf to 5.2gf. The depth of the first bag net and the second bag net were decreased about 50% than that of initial depth. 3. For the deformed angle of fish court net according to the attached point of the added sinker, A-type and B-type were decreased about 25% and 10% than the prototype, respectively. C-type was similar to the case of the prototype and D-type was increased about 15% than that of the prototype. The depth of slope net became deep in turn of A-type, B-type, C-type and D-type. For the depth of the second bag net, A-type, B-type, C-type and D-type were increased about 10${\sim}$15% than that of prototype. The depth of the slope net was changed from 0$^{\circ}$ to 63$^{\circ}$ and that of the second bag net was changed from 0${\sim}$44$^{\circ}$ according to the increase of velocity. 4. The optimal weight of added sinker was about 2.6${\sim}$3.6gf and the optimal attached point of added sinker was the case of C-type and D-type.

Hepatogenic Potential of Umbilical Cord Derived-Stem Cells and Human Amnion Derived-Stem Cells (사람의 제대 및 양막유래 줄기세포의 간세포로의 분화)

  • Kim, Ji-Young;Lee, Yoon-Jung;Park, Se-Ah;Kang, Hyun-Mi;Kim, Kyung-Sik;Cho, Dong-Jae;Kim, Hae-Kwon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.4
    • /
    • pp.247-265
    • /
    • 2008
  • Objectives: Many types of liver diseases can damage regenerative potential of mature hepatocytes, hepatic progenitor cells or oval cells. In such cases, a stem cell-based therapy can be an alternative therapeutic option. We examined whether human amnion-derived mesenchymal stem cells (HAM) and human umbilical cord-derived stem cells (HUC) could differentiate into hepatocyte-like cells as therapeutic cells for the liver diseases. Methods: HAM and HUC were isolated from the amnion and umbilical cord of the volunteers after a caesarean section with informed consent. In order to differentiate these cells into hepatocyte-like cells, cells were cultivated in hepatogenic medium using culture plates coated with fibronectin. Effects of hepatocyte growth factor, L-ascorbic acid 2-phosphate, insulin premixture fibroblast growth gactor 4, dimethylsulfoxide, oncostatin M and/or dexamethasone were examined on the hepatic differentiation. After differentiation, the cells were analyzed by RT-PCR, immunocytochemistry, immunoblotting, albumin ELISA, urea assay and periodic acid-schiffs staining. Results: Initial fibroblast-like appearance of HAM and HUC changed to a round shape during culture in the hepatogenic medium. However, in all hepatogenic conditions examined, HUC secreted more amounts of albumin or urea into medium than HAM. Expression of some of hepatocyte-specific genes increased and expression of new genes were observed in HUC following cultivation in hepatogenic medium. Results of immunocytochemistry and immunoblotting analyses demonstrated that HUC secreted albumin into the culture medium. PAS staining further demonstrated that HUC could store glycogen inside of the cells. Conclusions: Both HUC and HAM could differentiate into albumin-secreting, hepatocyte-like cells. Under the same hepatogenic conditions examined, HUC more efficiently differentiated into hepatocyte-like cells compared with the HAM. The results suggest that HUC and HAM could be used as sources of stem cells for the cell-based therapeutics such as in liver diseases.

A Clinical and Radiologic Study of Acute Focal Bacterial Nephritis in Children (소아에서의 급성 국소성 세균성 신장염의 임상 및 방사선학적 고찰)

  • Song, Kum Ho;Huh, Kwon Hoe;Cho, Ok Yeon;Sim, Jae Hoon;Cho, Do Jun;Kim, Dug Ha;Min, Ki Sik;Yoo, Ki Yang;Lee, Kwan Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.4
    • /
    • pp.351-357
    • /
    • 2003
  • Purpose : To raise awareness of the clinical importance of, and the need for proper management of acute focal bacterial nephritis(AFBN), we analyzed 22 AFBN patients and 22 other upper urinary tract infection patients by use of comparative studies. Methods : From January 2000 to May 2002, 22 AFBN patients aged from 1 month to 12 months were selected. As a control group, 22 UTI patients with no radiologic abnormalities were selected and matched by age and sex. Results : The incidence of AFBN was more common in boys than in girls. Since both groups had similar symptoms, it was difficult to diagnose AFBN by clinical presentations alone. ESR and CRP were significantly higher in AFBN patients. The most common causative organism was E. coli in both groups. On the sonographic findings, the most lesions were seen on the upper lobe of the kidney; more frequently, on left kidney. The lesions showed globular or wedge-shaped increased echogenecity. $^{99m}Tc-DMSA$ scan showed the complete coincidence of the location, size and shape in all cases compared to the findings of renal sonography. Conclusion : The roles of renal sonography and DMSA scan were very important, and ultrasonography was an excellent initial tool in diagnosing AFBN. Since the degree of infection in AFBN is more severe than other urinary tract infections and evollution into a renal abscess is possible, early diagnosis and appropriate antibiotics therapy is essential.