• 제목/요약/키워드: initial matrix

검색결과 621건 처리시간 0.028초

한중콘크리트 개선을 위한 철가루와 활성탄 혼입 경화체 기초연구 (Properties of Iron Powder and Activated Carbon mixed Matrix for the Improvement of Cold Weather Concrete)

  • 김원종;김원식;김규용;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2022
  • By studying the characteristics of matrix insulated through heat generated through oxidation of iron powder, the basic research results on the possibility of buffering and applicability of Cold weather concrete as a curing method are presented. In order to prevent freezing due to a sharp decrease in temperature in the initial stage of curing, iron powder (Fe), powder activated carbon, which is a small amount of porous carbonaceous adsorbent, and salt (NaCl) as an oxidizing agent are replaced with iron powder admixture. As the curing temperature increases, the strength tends to increase, and when replacing the admixture at the same curing temperature, the strength slightly decreases. This is determined as a result of generating iron oxide through an oxidation reaction of iron powder, activated carbon, and NaCl generating a large amount of pores in the matrix. In addition, the internal temperature tends to increase as the mixing substitution rate increases, and it is judged that the oxidation heat of the iron powder mixture affects the increase of the internal temperature during curing. The higher the replacement rate of the iron powder mixture, the slightly lower the strength, but it is determined that freezing and melting that may occur in the early stage of curing can be prevented due to an increase in the initial internal temperature.

  • PDF

Well-Conditioned 관측기 설계 - A Linear Matrix Inequality Approach - (Design of the Well-Conditioned Observer - A Linear Matrix Inequality Approach -)

  • 정종철;허건수
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.503-510
    • /
    • 2004
  • In this paper, the well-conditioned observer for a stochastic system is designed so that the observer is less sensitive to the ill-conditioning factors in transient and steady-state observer performance. These factors include not only deterministic uncertainties such as unknown initial estimation error, round-off error, modeling error and sensing bias, but also stochastic uncertainties such as disturbance and sensor noise. In deterministic perspectives, a small value in the L$_{2}$ norm condition number of the observer eigenvector matrix guarantees robust estimation performance to the deterministic uncertainties. In stochastic viewpoints, the estimation variance represents the robustness to the stochastic uncertainties and its upper bound can be minimized by reducing the observer gain and increasing the decay rate. Both deterministic and stochastic issues are considered as a weighted sum with a LMI (Linear Matrix Inequality) formulation. The gain in the well-conditioned observer is optimally chosen by the optimization technique. Simulation examples are given to evaluate the estimation performance of the proposed observer.

Curved beam through matrices associated with support conditions

  • Gimena, Faustino N.;Gonzaga, Pedro;Valdenebro, Jose V.;Goni, Mikel;Reyes-Rubiano, Lorena S.
    • Structural Engineering and Mechanics
    • /
    • 제76권3호
    • /
    • pp.395-412
    • /
    • 2020
  • In this article, the values of internal force and deformation of a curved beam under any action with the firm or elastic supports are determined by using structural matrices. The article presents the general differential formulation of a curved beam in global coordinates, which is solved in an orderly manner using simple integrals, thus obtaining the transfer matrix expression. The matrix expression of rigidity is obtained through reordering operations on the transfer notation. The support conditions, firm or elastic, provide twelve equations. The objective of this article is the construction of the algebraic system of order twenty-four, twelve transfer equations and twelve support equations, which relates the values of internal force and deformation associated with the two ends of the directrix of the curved beam. This final algebraic system, expressed in matrix form, is divided into two subsystems: twelve algebraic equations of internal force and twelve algebraic equations of deformation. The internal force and deformation values for any point in the curved beam directrix are determined from these values in the initial position. The five examples presented show how to apply the matrix procedures developed in this article, whether they are curved beams with the firm or elastic support.

On the influence of polymer surface layer thickness on the adhesion of composite assembly. Differences between initial state and thermal ageing.

  • Benard, Q.;Fois, M.;Picard, C.;Grisel, M.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.363-363
    • /
    • 2006
  • Bonding of composite materials with an adhesive layer is one of the most promising alternatives to classical bonding techniques. The use of several surface treatments may greatly increase this adhesion behavior at the initial state. Then in order to see the influence of the thickness of polymer matrix on the adhesion of composite assembly, different surface treatment, which can reduce or increase this thickness, are used (peel ply, tear ply, excimer laser). The influence of this specific parameter is not only discussed at the initial state but also after thermal ageing of the whole bonded assembly. Results show that the best performances at the initial state are not obviously the best performances after ageing.

  • PDF

법랑기질 단백질 유도체가 치주인대양세포 및 조골양세포에 미치는 영향 (Effects of enamel matrix protein derivatives on the periodontal ligament like fibroblast and osteoblast like cells)

  • 김동운;정진형;임성빈;고선일
    • Journal of Periodontal and Implant Science
    • /
    • 제33권2호
    • /
    • pp.225-246
    • /
    • 2003
  • Recent study on the enamel matrix derivatives explained on the effects of new bone and new attachment formation in infrabony pocket of periodontal defects. The purpose of this study was to investigate on the biological effects of enamel matrix derivatives to attachment, proliferation and activation of periodontal ligament and osteoblast cells, After treatment of osteoblast and PDL cells with various Emdogain concentration level(0.03${\mu}g$/ml, 3${\mu}g$/ml, 300${\mu}g$/ml), activation of osteogenetic factor, calcified nodule formation and measuring alkaline phosphatase activity(ALP) were performed. 1. Both osteoblast and PDL cell showed increasing initial cell attachment with 300${\mu}g$/ml Emdogain concentration. 2. At the level of 300${\mu}g$/ml, accelerated proliferation of oseoblast and PDL cell was appeared. 3. As Emdogain's concentration increased, increased ALP activation of osteoblast was shown. In case of PDL cell, Emdogain increased ALP activation prominently at the level of 300${\mu}g$/ml. 4. No statistically significant activating change were founded at all of the concentrations of Emdogain on the activating of transcript factor Runx2 for differentiating osteoblast. 5. At the level of 300${\mu}g$/ml, calcified nodule formation was increased prominently to compare with other concentration. These results indicated that Emdogain should activate initial attachment, proliferation and activation, but not on Runx2 activation and can be used for useful tool of the treatment of periodontal tissue regeneration.

SiC입자강화 주조Al-Si복합재의 피로수명에 대한 인장평균변형률의 영향 (Tensile Mean Strain Effects on the Fatigue Life of SiC-Particulate-Reinforced Al-Si Cast Alloy Composites)

  • 고승기
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1970-1981
    • /
    • 1999
  • The low-cycle fatigue behaviour of a SiC-particulate-reinforced Al-Si cast alloy with two different volume fractions has been investigated from a series of strain-control led fatigue tests with zero and nonzero tensile mean strains. The composites including the unreinforced matrix alloy, exhibited cyclic hardening behaviour, with more pronounced strain-hardening for the composites with a higher volume fraction of the SiC particles. For the tensile mean strain tests, the initial high tensile mean stress relaxed to zero for the ductile Al-Si alloy, resulting in no influence of the tensile mean strain on the fatigue life of the matrix alloy. However, tensile mean strain for the composite caused tensile mean stresses and reduced fatigue life. The pronounced effects of mean strain on the low-cycle fatigue life of the composite compared to the unreinforced matrix alloy were attributed to the initial large prestrain and non-relaxing high tensile mean stress in the composite with very limited ductility and Cyclic plasticity. Fatigue damage parameter using strain energy, density efficiently accounted for the mean stress effects. Predicted fatigue life using the damage parameter correlated fairly well with the experimental life within a factor of 3. Also, the fatigue damage parameter indicated the inferior life in the low-cycle regime and superior life in the high-cycle regime for the composite, compared to the unreinforced matrix alloy.

64-위상 출력 클럭을 가지는 125 MHz CMOS 지연 고정 루프 (A 125 MHz CMOS Delay-Locked Loop with 64-phase Output Clock)

  • 이필호;장영찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.259-262
    • /
    • 2012
  • 본 논문에서는 125 MHz 동작 주파수에서 64개 위상의 클럭을 출력하는 지연 고정 루프 (DLL: delay-locked loop)을 제안한다. 제안된 다중 지연 고정 루프는 delay line의 선형성을 개선하기 위해 $4{\times}8$ matrix 구조의 delay line을 사용한다. CMOS multiplexer와 inverter-based interpolator를 이용하여 $4{\times}8$ matrix 기반의 delay line에서 출력된 32개 위상의 클럭으로부터 64개 위상의 클럭을 생성한다. 또한 DLL에서 harmonic lock을 방지하기 위해 클럭의 duty cycle ratio에 무관한 initial phase locking을 위한 회로가 제안된다. 제안된 지연 고정 루프는 1.8 V의 공급전압을 이용하는 $0.18-{\mu}m$ CMOS 공정에서 설계된다. 시뮬레이션된 DLL은 40 MHz에서 200 MHz의 동작 주파수 범위를 가진다. 125 MHz 동작 주파수에서 최악의 위상 오차와 jitter는 각각 +11/-12 ps와 6.58 ps이다.

  • PDF

Short-term changes of human acellular dermal matrix (Megaderm) in a mouse model

  • Kim, Yang Seok;Na, Young Cheon;Yoon, Hyun Sik;Huh, Woo Hoe;Kim, Ji Min
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.10-16
    • /
    • 2019
  • Background: Physicians tend to overcorrect when applying the acellular dermal matrix for reconstructive option because of volume decrement problem after absorption comparing with initial volume. However, there are no studies on the exact volume decrement and absorption rate with commercial products in South Korea. To figure out absorption rate of acellular dermal matrix product in South Korea (Megaderm), authors designed this experiment. Methods: Nine mice were used and randomly divided into three groups by the time with sacrificing. The implant (Megaderm) was tailored to fit a cuboid form ($1.0cm{\times}1.0cm$ in length and width and 2.0 mm in thickness). A skin incision was made at anterior chest with blade #15 scalpel with exposing the pectoralis major muscle. As hydrated Megaderm was located upon the pectoralis major muscle, the skin was sutured with Ethilon #5-0. After the surgical procedure, each animal group was sacrificed at 4, 8, and 12 weeks, respectively, for biopsies and histological analysis of the implants. All samples were stained with routine hematoxylin and eosin staining and Masson's trichrome staining and the thickness were measured. A measurements were analyzed using Friedman test. Statistically, the correlation between thicknesses of Megaderm before and after implantation was analyzed. Results: After sacrificing the animal groups at postoperative 4, 8, 12 weeks, the mean tissue thickness values were $2.10{\pm}1.03mm$, $2.17{\pm}0.21mm$, and $2.40{\pm}0.20mm$ (p= 0.368), respectively. The remaining ratios after absorption comparing with after initial hydrated Megaderm were 82.7%, 85.4%, and 94.5%, respectively. In histopathological findings, neovascularization and density of collagenous fiber was increased with time. Conclusion: Author's hypothesis was absorption rate of implant would be increased over time. But in this experiment, there is no statistical significance between mean absorption thickness of implant and the time (p= 0.368). Also it can be affected by graft site, blood supply, and animals that were used in the experiment.

미세구조 조절에 의한 고투자율 Mn-Zn Ferrite의 특성제어 (Control of Electromagnetic Properties of High Initial Permeability Mn-Zn Ferrite with the Microstructure Control)

  • 도세욱;류지태;김정희;강태현;허원도
    • 자원리싸이클링
    • /
    • 제7권4호
    • /
    • pp.50-54
    • /
    • 1998
  • 원하는 전자기적 특성인 높은 초투자율과 우수한 주파수 의존특성을 얻기 위해 Mn-Zn 페라이트계에서 핵입자의 첨가효과를 실험하였다. 소결온도에서 가소된 핵입자를 첨가함에 따라 비정상 입자성장이 말끔히 사라졌지만, 페라이트의 소결밀도와 초투자율이 감소하였다. 이와 반대로 매트릭스 입자의 가소온도보다 낮은 온도에서 가소된 핵입자의 첨가시에는 비정상 입자성장이 잔유하였으나, 적정한 핵입자 첨가로 Cutoff Frequency가 변화하지 않는 가운데 10∼20%의 초투자율값의 상승이 있었다.

  • PDF

이중조직을 갖는 Y-TZP/Y-TZP-$Al_2O_3$ 복합체의 열충격 거동 (The Thermal Shock Behaviors of Y-TZP/Y-TZP-Al2O3 Composites having Dual Microstructure)

  • 황규홍;김의훈;김환
    • 한국세라믹학회지
    • /
    • 제29권4호
    • /
    • pp.283-292
    • /
    • 1992
  • Duplex composites such as Y-TZP/Y-TZP-20 wt.% Al2O3 and Y-TZP/Y-TZP- 40 wt.% Al2O3 were made by mixing the sieve-shaked granules followed by isostatic pressing and sintering at 150$0^{\circ}C$ for 1 hour. So Y-TZP became matrix region and Y-TZP-20 wt.% Al2O3 or Y-TZP-40 wt.% Al2O3 became dispersed regions. In these composites, propagating cracks due to thermal shock always run into the dispersed region because these regions act as compressive zone due to low thermal expansion than matrix region. So duplexes having dispersed regions of Y-TZP-40 wt.% Al2O3 showed higher retained strength after thermal shock than matrix only composites because crack propagations were stopped more or less in the dispersed region. But when crack propagations were much more easy than matrix like Y-TZP-20 wt.% Al2O3 region, retained strength was decreased than the matrix only composites despite of the low initial strength.

  • PDF