• Title/Summary/Keyword: inhomogeneous organ

Search Result 3, Processing Time 0.019 seconds

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

The Evaluation of the dose calculation algorithm(AAA)'s Accuracy in Case of a Radiation Therapy on Inhomogeneous tissues using FFF beam (FFF빔을 사용한 불균질부 방사선치료 시 선량계산 알고리즘(AAA)의 정확성 평가)

  • Kim, In Woo;Chae, Seung Hoon;Kim, Min Jung;Kim, Bo Gyoum;Kim, Chan Yong;Park, So Yeon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.321-327
    • /
    • 2014
  • Purpose : To verify the accuracy of the Ecilpse's dose calculation algorithm(AAA:Analytic anisotropic algorithm) in case of a radiation treatment on Inhomogeneous tissues using FFF beam comparing dose distribution at TPS with actual distribution. Materials and Methods : After acquiring CT images for radiation treatment by the location of tumors and sizes using the solid water phantoms, cork and chest tumor phantom made of paraffin, we established the treatment plan for 6MV photon therapy using our radiation treatment planning system for chest SABR, Ecilpse's AAA(Analytic anisotropic algorithm). According to the completed plan, using our TrueBeam STx(Varian medical system, Palo Alto, CA), we irradiated radiation on the chest tumor phantom on which EBT2 films are inserted and evaluated the dose value of the treatment plan and that of the actual phantom on Inhomogeneous tissue. Results : The difference of the dose value between TPS and measurement at the medial target is 1.28~2.7%, and, at the side of target including inhomogeneous tissues, the difference is 2.02%~7.40% at Ant, 4.46%~14.84% at Post, 0.98%~7.12% at Rt, 1.36%~4.08% at Lt, 2.38%~4.98% at Sup, and 0.94%~3.54% at Inf. Conclusion : In this study, we discovered the possibility of dose calculation's errors caused by FFF beam's characteristics and the inhomogeneous tissues when we do SBRT for inhomogeneous tissues. SBRT which is most popular therapy method needs high accuracy because it irradiates high dose radiation in small fraction. So, it is supposed that ideal treatment is possible if we minimize the errors when planning for treatment through more study about organ's characteristics like Inhomogeneous tissues and FFF beam's characteristics.

Unifocal Langerhans Cell Histiocytosis of Frontal Bone in a Child (소아 전두골에 발생한 랑게르한스세포 조직구증)

  • Hong, Seong Jae;Cho, Sang Hun;Eo, Su Rak
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.69-72
    • /
    • 2013
  • Lateral eyebrow mass with primary skull lesion are rare in pediatric population. Although epidermoid cyst and dermoid cyst are the most commonly encountered skull lesions in pediatric population, Langerhans cell histiocytosis (LCH) is rarely reported. We report a case of LCH arising from the lateral eyebrow with osteolytic lesion involving the frontal bone. A 5-year-old boy was presented with a hard, fixed mass in his lateral eyebrow. Contrast magnetic resonance imaging revealed inhomogeneous enhancement of the mass with direct invasion of the frontal bone and adjacent dura mater. Under general anesthesia, linear incision at the lateral eyebrow region was made. Intraoperative evaluation revealed hard, fixed and well-defined soft tissue mass. The final extirpated mass was $2.5{\times}2.4cm$ in size, and was accompanied by a $1{\times}1cm$ sized defect on the frontal bone with intact dura mater. The surgical wound was closed primarily by a layer-by-layer fashion. Histologic examination was later performed for definite diagnosis. The histologic examination revealed abnormal proliferation of Langerhans cell with granuloma formation. Radionuclide bone scan and positron emission tomography was taken and revealed free of multi-organ involvement. At 3 months after surgery, natural looking contour at the lateral eyebrow region was observed with no tumor recurrence. Differential diagnosis of the hard and fixed mass at the lateral eyebrow region affecting the primary skull lesion from pediatric population includes epidermoid cyst, dermoid cyst and LCH. Generally, brief physical examination with plain X-ray view can be performed for clinical evaluation, but for a definite diagnosis, contrast MRI may be helpful.