• Title/Summary/Keyword: infrared rays

Search Result 178, Processing Time 0.039 seconds

Design and Construction of a High Temperature Creep Tester for Thin Film Specimens (박막시험편용 고온 크리프 시험기의 설계 및 제작)

  • Ko, Gyoung-Dek;Lee, Sang-Shin;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.253-259
    • /
    • 2007
  • A new material tester has been developed to measure mechanical properties of thin film specimens at high temperature. It is useful for observing oxide film growth or local deformation on the surface, and for measuring creep strength. Main characteristics of the tester is as follows; First, high temperature is achieved by Joule heating generated by electricity passing through the specimen, which does not need to enclose the specimen by a furnace or a heating chamber. The exposed specimen enables one to observe the surface during the test. Because the overall size of the test rig is compact, the whole test rig can be placed in a chamber for environmental controlled tests. The loading device is from a level scales. Not only static load with fixed counter weight, but also variable load by moving counter weight controlled remotely can be applied for an ordinary creep test and creep-fatigue test, respectively. The detail of the construction, operation principle, and the specification are described. And also, an example of test result obtained using the creep tester is presented.

Effect of Electron Beam and ${\gamma}$-Ray Irradiation on the Curing of Epoxy Resin

  • Kang, Phil-Hyun;Park, Jong-Seok;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.332-338
    • /
    • 2002
  • The effect of an electron beam and ${\gamma}$-ray irradiation on the curing of epoxy resins was investigated. Diglycidyl ether of bisphenol A (DGEBA) and diglycidyl ether of bisphenol F (DGEBF) as epoxy resin were used. The epoxy resins containing 1.0-3.() wt% of triarylsulphonium hexafluoroantimonate(TASHFA) and triarylsulphonium hexafluorophosphate(TASHFP) as initiator were irradiated under nitrogen at room temperature with different dosage of EB and ${\gamma}$-rays from a Co$^{60}$ u source. The chemical and mechanical characteristics of irradiated epoxy resins were compared after curing of EB and ${\gamma}$-ray irradiation. The thermal properties of cured epoxy were investigated using dynamic mechanical thermal analysis. The chemical structures of cured epoxy were characterized using near infrared spectroscopy. Mechanical properties such as flexural strength, modulus were measured. The gel fraction of DGEBA with ${\gamma}$-ray was higher than that of the epoxy with EB at the same dose. Young's modulus of the sample irradiated by ${\gamma}$-ray is higher than that of sample cured by EB. From the result of strain at yield, it was found that the epoxy cured by ${\gamma}$-ray had a higher stiff property compared with the irradiated by EB.

Underwater Multi-media Communication Network based on Star Topology and a Fragmentation Technique (성형망 기반의 수중 다중매체 통신 네트워크와 단편화 기법)

  • Lim, DongHyun;Kim, Seung-Geun;Kim, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.11
    • /
    • pp.1526-1537
    • /
    • 2021
  • Due to the difference between the underwater communication environment and the terrestrial communication environment, the radio communication mainly used on the ground cannot be used in underwater. For this reason, in the underwater communication environment, various communication media such as acoustic waves, infrared rays, light and so on has been studied, but there exist several difficulties in operating them individually due to their physical limitations. The concept for overcoming these difficulties is the very underwater multi-media communication, a method to select a communication medium best suitable for the current underwater environment among underwater communication multimedia whenever there occurs underwater communication failure. In this paper, we present an underwater multi-media communication network based on star topology and a fragmentation and reassembly technique to solve the problems caused by the different MTU (Maximum Transmission Unit) sizes among different underwater communication media. We also present the estimations and analysis on processing times in each of fragmentation and reassembly and the total data amount for transmitting fragments in our proposed underwater multi-media communication network.

A Study on the quantitative measurement methods of MRTD and prediction of detection distance for Infrared surveillance equipments in military (군용 열영상장비 최소분해가능온도차의 정량적 측정 방법 및 탐지거리 예측에 관한 연구)

  • Jung, Yeong-Tak;Lim, Jae-Seong;Lee, Ji-Hyeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.557-564
    • /
    • 2017
  • The purpose of the thermal imaging observation device mounted on the K's tank in the Republic of Korea military is to convert infrared rays into visual information to provide information about the environment under conditions of restricted visibility. Among the various performance indicators of thermal observation devices, such as the view, magnification, resolution, MTF, NETD, and Minimum Resolvable Temperature Difference (MRTD), the MRTD is the most important, because it can indicate both the spatial frequency and temperature resolvable. However, the standard method of measuring the MRTD in NATO contains many subjective factors. As the measurement result can vary depending on subjective factors such as the human eye, metal condition and measurement conditions, the MRTD obtained is not stable. In this study, these qualitative MRTD measurement systems are converted into quantitative indicators based on a gray scale using imaging processing. By converting the average of the gray scale differences of the black and white images into the MRTD, the mean values can be used to determine whether the performance requirements required by the defense specification are met. The (mean) value can also be used to discriminate between detection, recognition and identification and the detectable distance of the thermal equipment can be analyzed under various environmental conditions, such as altostratus, heavy rain and fog.

Autonomic Nerve Change after Loess Bedding Radiating Far-infrared ray and energy (원적외선에너지 방출 황토침구 사용 후의 자율신경 변화에 대한 연구)

  • Lee, Ku Yeon;Lee, Hyung H.;Hahm, Suk Chan
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the changes in the autonomic nervous system of the human body after the use of ocher bedding radiating far-infrared rays to 15 insomnia subjects. Methods: Changes of autonomous nerve in the subjects after using loess bedding estimated by heart rate variability. Results: The mean HF before the use of ocher bedding was 220.8 msec2, and the mean after use decreased to 5.1 msec2. The average value of LF before use was 418.1 msec2, and the mean after use decreased to 5.2 msec2. The average before use of the VLF was 1463.3 msec2, and the average after use dropped to 6.8 msec2. The average value of TP before use was 977.3 msec2, and the average after use dropped to 6.7 msec2. The decrease in postoperative values of all four items was statistically significant, and the high value of the subjects before use inferred to be the reason that all of the subjects had high stress and anxiety due to their long-term sleep disorder. There was no significant difference in the pulses of the subjects before the use of the bedding. SDNN and RMSSD were not significantly different before and after use. Conclusions: Autonomic nerves HF, LF, VLF, TP frequency is evaluated to be affected by the investigation of far-infrared radiation that occurs ocher. This research data regarded as high value as primary data in this field.

Optimization of Electro-Optical Properties of Acrylate-based Polymer-Dispersed Liquid Crystals for use in Transparent Conductive ZITO/Ag/ZITO Multilayer Films (투명 전도성 ZITO/Ag/ZITO 다층막 필름 적용을 위한 아크릴레이트 기반 고분자분산액정의 전기광학적 특성 최적화)

  • Cho, Jung-Dae;Kim, Yang-Bae;Heo, Gi-Seok;Kim, Eun-Mi;Hong, Jin-Who
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.291-298
    • /
    • 2020
  • ZITO/Ag/ZITO multilayer transparent electrodes at room temperature on glass substrates were prepared using RF/DC magnetron sputtering. Transparent conductive films with a sheet resistance of 9.4 Ω/㎡ and a transmittance of 83.2% at 550 nm were obtained for the multilayer structure comprising ZITO/Ag/ZITO (100/8/42 nm). The sheet resistance and transmittance of ZITO/Ag/ZITO multilayer films meant that they would be highly applicable for use in polymer-dispersed liquid crystal (PDLC)-based smart windows due to the ability to effectively block infrared rays (heat rays) and thereby act as an energy-saving smart glass. Effects of the thickness of the PDLC layer and the intensity of ultraviolet light (UV) on electro-optical properties, photopolymerization kinetics, and morphologies of difunctional urethane acrylate-based PDLC systems were investigated using new transparent conducting electrodes. A PDLC cell photo-cured using UV at an intensity of 2.0 mW/c㎡ with a 15 ㎛-thick PDLC layer showed outstanding off-state opacity, good on-state transmittance, and favorable driving voltage. Also, the PDLC-based smart window optimized in this study formed liquid crystal droplets with a favorable microstructure, having an average size range of 2~5 ㎛ for scattering light efficiently, which could contribute to its superior final performance.

A Study of Electro-Optical Properties of Polyester Acrylate-Based Polymer-Dispersed Liquid Crystals Using TIZO/Ag/TIZO Multilayer Transparent Electrodes (TIZO/Ag/TIZO 다층막 투명전극을 이용한 폴리에스터 아크릴레이트 기반 고분자분산액정의 전기광학적 특성 연구)

  • Cho, Jung-Dae;Heo, Gi-Seok;Hong, Jin-Who
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Ti-In-Zn-O (TIZO)/Ag/TIZO multilayer transparent electrodes were prepared on glass substrates at room temperature using RF/DC magnetron sputtering. Obtained multilayer structure comprising TIZO/Ag/TIZO (10 nm/10 nm/40 nm) with the total thickness of 60 nm showed a transmittance of 86.5% at 650 nm and a sheet resistance of 8.1 Ω/□. The multilayer films were expected to be applicable for use in energy-saving smart window based on polymer-dispersed liquid crystal (PDLC) because of their transmittance properties to effectively block infrared rays (heat rays). We investigated the effects of the content ratio of prepolymer, the thickness of the PDLC coating layer, and the ultraviolet (UV) light intensity on electro-optical properties, and the surface morphology of polyester acrylate-based PDLC systems using new TIZO/Ag/TIZO transparent conducting electrodes. A PDLC cell with a thickness of 15 ㎛ PDLC layer photocured at an UV intensity of 1.5 mW/cm2 exhibited good driving voltage, favorable on-state transmittance, and excellent off-haze. The LC droplets formed on the surface of the polymer matrix of the PDLC composite had a size range of 1 to 3 ㎛ capable of efficiently scattering incident light. Also, the PDLC-based smart window manufactured using TIZO/Ag/TIZO multi-layered transparent electrodes in this study exhibited a light brown, which will have an advantage in terms of aesthetics.

Opto-mechanical Analysis for Primary Mirror of Earth Observation Camera of the MIRIS (MIRIS EOC 주경의 광기계 해석)

  • Park, Kwi-Jong;Moon, Bong-Kon;Park, Sung-Jun;Park, Young-Sik;Lee, Dae-Hee;Ree, Chang-Hee;Nah, Jak-Young;Jeong, Woog-Seob;Pyo, Jeong-Hyun;Lee, Duk-Hang;Nam, Uk-Won;Rhee, Seung-Wu;Yang, Sun-Choel;Han, Won-Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.6
    • /
    • pp.262-268
    • /
    • 2011
  • MIRIS(Multi-purpose Infra-Red Imaging System) is the main payload of the STSAT-3(Korea Science and Technology Satellite. 3), which is being developed by KASI(Korea Astronomy & Space Institute). EOC(Earth Observation Camera), which is one of two infrared cameras in MIRIS, is the camera for observing infrared rays from the Earth in the range of $3{\sim}5{\mu}m$. The optical system of the EOC is a Cassegrain prescription with aspheric primary and secondary mirrors, and its aperture is 100mm. A ring type flexure supports the EOC primary mirror with pre-loading in order to withstand expected load due to the shock and vibration from the launcher. Here we attempt to use the same mechanism by which a retainer supports the lens. Through opto-mechanical analysis it was confirmed that the EOC primary mirror is effectively supported.

HOT GAS HALOS IN EARLY-TYPE GALAXIES AND ENVIRONMENTS

  • Kim, Eunbin;Choi, Yun-Young;Kim, Sungsoo S.
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • We investigate the dependence of the extended X-ray emission from the halos of optically luminous early-type galaxies on the small-scale (the nearest neighbor distance) and large-scale (the average density inside the 20 nearest galaxies) environments. We cross-match the 3rd Data Release of the Second XMMNewton Serendipitous Source Catalog (2XMMi-DR3) to a volume-limited sample of the Sloan Digital Sky Survey (SDSS) Data Release 7 with $M_r$ < -19.5 and 0.020 < z < 0.085, and find 20 early-type galaxies that have extended X-ray detections. The X-ray luminosity of the galaxies is found to have a tighter correlation with the optical and near infrared luminosities when the galaxy is situated in the low large-scale density region than in the high large-scale density region. Furthermore, the X-ray to optical (r-band) luminosity ratio, $L_X/L_r$, shows a clear correlation with the distance to the nearest neighbor and with large-scale density environment only where the galaxies in pair interact hydrodynamically with seperations of $r_p$ < $r_{vir}$. These findings indicate that the galaxies in the high local density region have other mechanisms that are responsible for their halo X-ray luminosities than the current presence of a close encounter, or alternatively, in the high local density region the cooling time of the heated gas halo is longer than the typical time between the subsequent encounters.

Implementation of a Fragmentation Method for Flow Control in Underwater Multi-media Communication (수중 다중 매체 통신의 흐름제어를 위한 단편화 기법 구현)

  • You, Dongsun;Shin, DongHyun;Lim, Seungsoo;Jeon, Seonghyun;Kim, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.7
    • /
    • pp.819-829
    • /
    • 2020
  • Underwater communication is necessarily useful for various application domains such as saving of human lives from underwater disasters, marine resource exploration, underwater military fields, underwater environment or ecosystem monitoring, fish farm monitoring and management, etc. Even though the acoustic wave has been the main underwater communication media until now, several media such as optical waves, VLF/ELF waves, magnetic fields, and infrared rays also began to be treated as possible media for underwater communication. If these underwater communicate-possible media are used mixing together, the underwater communication can be much more reliable and efficient through complementing the disadvantages of each communication media with advantages of other communication media. In fact, mixing and using multi-media for underwater communication requires the data flow control in the connection process of different media due to their communication speed gaps and bandwidth differences, and, specially, in the flow control, the appropriate message fragmentation technique is required inevitably. For this reason, this paper presents a fragmentation framework and technique necessary to the flow control in the underwater multi-media communication. In addition, through its implementation and experiments, this paper shows the feasibility on the realization of the multi-media based underwater communication.