• Title/Summary/Keyword: infrared

Search Result 8,087, Processing Time 0.03 seconds

Drying Characteristics of Squids According to Far Infrared and Heated Air Drying Conditions (원적외선과 열풍 건조조건에 따른 오징어의 건조특성)

  • Kang, Tae-Hwann;Hong, Hyun-Gi;Jeon, Hong-Young;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.109-115
    • /
    • 2011
  • Drying characteristics of squids under two dry conditions were investigated using far infrared and heated air. Dry temperatures of 40, 50 and $60^{\circ}C$ with air speed of 0.6, 0.8 and 1.2 m/s were used for evaluating far infrared squid drying. Heated air squid drying at 40 and $50^{\circ}C$ with air speed of 0.8 m/s was used as a control treatment. The two drying were evaluated in terms of drying rate, color, TBA value, aerobic bacteria, cutting shear, penetration strength, and energy consumption. The drying rate of far infrared drying was relatively faster than that of heated air drying. The drying time of far infrared drying was reduced as the drying temperature increased. The color difference of far infrared dried squids was from 18.81 to 22.85, and heated air dried squid had the color different from 23.94 to 24.09. Far infrared dried squid had relatively smaller TBA values that indicate a level of rancidity. The aerobic bacteria of heated air dried squid increased from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g before and after drying, respectively. Far infrared dried squid had relatively smaller increase (from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g). The cutting shear and penetration strength for far infrared dried squids was relatively lower. In addition, far infrared squid drying consumed relatively less energy compared to heated air drying.

Far Infrared Rays Drying Characteristics of Tissue Cultured Mountain Ginseng Roots (산삼배양근의 원적외선 건조특성)

  • Li, H.;Kwang, T.H.;Ning, X.F.;Cho, S.C.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.175-182
    • /
    • 2009
  • This study was conducted to investigate the drying characteristics of tissue cultured mountain ginseng roots. The far infrared rays dryer of a double blast system used for this experiment can control the drying parameters such as far infrared heater temperature and air velocity. The far infrared rays drying tests of tissue cultured mountain ginseng roots were performed at air velocity of 0.4, 0.6, 0.8 m/s, under drying air temperature of 50, 60, and $70^{circ}C$, respectively. The results were compared with one obtained by the heated air drying method. The drying characteristics such as drying rate, color, energy consumption, saponin components and antioxidant activities were analyzed. The results showed that the drying rate of far infrared rays drying was faster than that of heated air drying and due to high temperature of drying air and fast air velocity, the far infrared rays drying of double blast type was superior to the heated air drying. The value of the color difference for heated air drying was 10.11${\sim}$12.99 and that of far infrared rays drying was in the range of 7.05${\sim}$7.54, which was in the same drying condition, also energy consumption of far infrared rays drying was in the range of 3575${\sim}$6898 kJ/kg-water. At the same time, the antioxidant activities using far infrared rays drying were higher than those using heated air drying.

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

An Experimental Study on the Relationship Between Temperature and Pressure Inside the Cup During Cupping Procedures

  • Lee, Ha Lim;An, Soo Kwang;Lee, Jae Yong;Shim, Dong Wook;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.38 no.1
    • /
    • pp.41-46
    • /
    • 2021
  • Background: Pressure changes related to temperature variation during cupping may lead to dropout. This study aimed to investigate pressure changes related to temperature variations in the cup during the cupping procedure. Methods: Changes in temperature and pressure were measured for 15 minutes after the procedure was performed using the alcohol rub method with glass cups and with the addition of infrared irradiation. Changes in temperature and pressure were also measured for 15 minutes after pumping 3 times using the valve suction method, and with the addition of infrared irradiation. Results: In a comparison between the alcohol rub method with glass cups and with the addition of infrared irradiation, the negative pressure increased over time in the absence of infrared irradiation, whereas it decreased when performed with infrared irradiation p = 0.094. However, in a comparison between pumping 3 times using the valve suction method, and with the addition of infrared irradiation, the negative pressure decreased in both cases, but this was more significant with infrared irradiation p = 0.172. There was a significantly higher temperature in the glass cups (p = 0.004) and the valve cups (p = 0.001) exposed to infrared radiation, compared with no infrared irradiation. Conclusion: The reduction in negative pressure inside the cups exposed to infrared radiation was greater than without infrared irradiation. Temperature increases inside the cup can lead to the risk of dropout.

Effect of Far-Infrared Finishing on Brassiere Pad

  • Shin Jung-Sook
    • The International Journal of Costume Culture
    • /
    • v.8 no.2
    • /
    • pp.124-131
    • /
    • 2005
  • This study focused on the change of skin temperature by the emissivity and emission power of far-infrared for conformant far infrared effect to naked eyes. The study method is to manufacture the bra pad by each concentration on far-infrared materials of illite powder $(K,H_3O)AI_2(Si,Al)_4O_{10}(H_2O,OH)_2)$, liquid alumina ($Al_2O_3$), the extracted liquid from 29 kind of medical plants, then, measured change of skin temperature. Result are as follows. Far-infrared were emitted each $90.2\%,\;90.1\%,\;89.7\%$ from the illite powder, liquid alumina, extracted liquid from medical plants. When the testee weared the bra pad, the temperature of coated bra pad was $0.5^{\circ}C$ higher than the non finished bra pad. Washing fastness on far-infrared finishing was better dope addition method than coating method.

  • PDF

On the Mural Paintings Detectedc by through the Infrared T.V.Camera at Josadang, Busuk Temple (부석사 조사당 벽화조사에 따른 적외선 T.V카메라 이용)

  • Chung, Kwang-Yong
    • 보존과학연구
    • /
    • s.7
    • /
    • pp.218-236
    • /
    • 1986
  • In the fields of the cultural properties, the Infrared TV camera is being initiated to use instead of the Infrared photo film fo a better means to detect the description of drawings of the paintings. Seeing from the effect of transillumination, the Infrared TV camera with its long wave of visible spectrum that makes less absorption by the pigments and with the reflection rays passing through the base of colour layers makes it able to findbase drawing and letters. The detection range of transillumination by the infrared rays depends on the kinds of pigments, lines of the base drawing and wave length of the infrared rays. In our country, it was the first time to detect by our Conservation Science Dep't of The Research Institute of Cultural Properties by means of using Infrared TV camera to determine the mural paintings on the Josadang, Busuk Temple, resulted in an epoch-making success, that we have come to know the painting technique methods, how to treat for its conservation and making replica, reproduction, etc.

  • PDF

Realization of Optic Systems for the Infrared Thermography (적외선 체열촬영시스템을 위한 광학계의 구성)

  • Lee, Soo-Yeol;Woo, Eung-Je;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.97-104
    • /
    • 1994
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensionaloptic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the infrared thermography system composed ofthe proposed optic system has the temperature resolution of $0.1{\circ}C$ under the spatial resolution of 1mrad, the image matrix size of $256{\times}240$, and the imaging time of 4 seconds.

  • PDF

A Practical FastSLAM Implementation Method using an Infrared Camera for Indoor Environments (실내 환경에서 Infrared 카메라를 이용한 실용적 FastSLAM 구현 방법)

  • Zhang, Hairong;Lee, Heon-Cheol;Lee, Beom-Hee
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.4
    • /
    • pp.305-311
    • /
    • 2009
  • FastSLAM is a factored solution to SLAM problem using a Rao-Blackwellized particle filter. In this paper, we propose a practical FastSLAM implementation method using an infrared camera for indoor environments. The infrared camera is equipped on a Pioneer3 robot and looks upward direction to the ceiling which has infrared tags with the same height. The infrared tags are detected with theinfrared camera as measurements, and the Nearest Neighbor method is used to solve the unknown data association problem. The global map is successfully built and the robot pose is predicted in real time by the FastSLAM2.0 algorithm. The experiment result shows the accuracy and robustness of the proposed method in practical indoor environment.

  • PDF

AKARI near Infrared spectroscopy of luminous infrared galaxies

  • Lee, Jong-Chul;Hwang, Ho-Seong;Lee, Myung-Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.50.2-50.2
    • /
    • 2012
  • We present the results of near infrared (2.5-5 micron) spectroscopy of nearby luminous infrared galaxies (LIRGs) using AKARI. The LIRG catalog is constructed from the cross-correlation between the Infrared Astronomical Satellite and the Sloan Digital Sky Survey data, and optically non-Seyfert type LIRGs are selected for main targets. We search for optically elusive active galactic nuclei (AGNs), based on the strengths of 3.3 micron polycyclic aromatic hydrocarbon emission and dust absorption features at 3-4 micron. We investigate the hidden AGN fraction as a function of the infrared luminosity and correlation between optical and near infrared star formation indicators.

  • PDF

Heat Analysis of Welding-bead using Infrared Thermoimage Camera (적외선 열화상 카메라를 이용한 용접 비드의 열 해석)

  • Kim, Jae-Yeol;Shim, Jae-Gi;Yang, Dong-Jo;Yu, Sin
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.57-62
    • /
    • 2000
  • Diagnosis or measurements using Infrared thermoimage hasn't been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermovision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the welding parts during welding process. Especially, diagnosis using Infrared camera plays an important role on thermal analysis of Axle Casing Nut for Commercial Vehicles.

  • PDF