• Title/Summary/Keyword: inflow concentration

Search Result 373, Processing Time 0.026 seconds

A Study on $Na^+$ and Water Reabsorption in the Nephron Segment Beyond Proximal Tubule Measured by Lithium Clearance

  • Han, O-Soo;Goo, Yong-Sook;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.189-200
    • /
    • 1991
  • During the past few years it has been proposed that lithium clearance can be used as a reliable measure for the outflow of tubular fluid from the proximal tubule. This study was aimed to characterize the inflow dependent reabsorption of Na in renal tubule beyond the proximal tubule. For this purpose, lithium clearance was used as a measure for the inflow from the proximal tubule and the changes in reabsorption fraction of Na and water were determined in rabbits. Rabbits were pretreated with hypotonic saline solutions for an hour (50 mM/L NaCl, 20 ml/hr/kg). And then a hypertonic solution of 500 mM/L NaCl (20 ml/kg) was administered intraperitoneally in conjunction with a bolus of LiCl solution (2 mM/kg, i.v.) for conditioning the $C_{Li}$ and urine flow rate. To rule out the effect of $Li^+$ on tubular functions, a bolus of NaCl solution (2 mM/kg, i.v.) was administered. Fifteen, thirty, and sixty minutes after injection of hypertonic saline arterial blood and urine samples were taken. Urinary and plasma concentrations as well as urinary output of $Li^+,\;Na^+\;and\;K^+$ were measured. From these $C_{Li},\;C_{Na}$ and the reabsorption fraction of Na and water $(Fr_{Na}\;&\;FrH_2O)$ were calculated. These results were compared with those from control groups in which the same amount of isotonic saline (145 mM/L NaCl) and of 15% dextran solution were administered in the same way as that in experimental group. Followings are the results obtained. 1) The plasma concentration of $Na^+$ in rabbits injected with hypertonic saline reached the peak value after 15 min and thereafter no significant change was observed. Hematocrit values did not show any change, while urinary excretion of $Na^+$ increased markedly during the first 15 min and decreased thereafter. These results were not affected by an injection of a small amount of LiCl. 2) The clearances of $Li^+,\;Na^+\;and\;K^+$ in rabbits injected with hypertonic saline and LiCl solution decreased. 3) In spite of the variation in $C_{Li},\;Fr_{Na}$ did not show any significant change while $FrH_2O$ increased gradually. 4) $C_{Li}$ decreased also in rabbits received isotonic saline. $Fr_{Na}$ tended to be higher than that in hypertonic saline group, while $FrH_2O\;and\;Fr_{Na}$ did not associated with the decrease in $C_{Li}$. 5) $C_{Li}$ of the rabbits received dextran solution fluctuated persistently and $Fr_{Na}\;and\;FrH_2O$ did not change in along with $C_{Li}$ although $Fr_{Na}$ had a tendency to be higher than that in hypertonic saline group. 6) From the above results it was concluded that: (a) In rabbits with normal body store of $Na^+$, the $Fr_{Na}$ of renal tubule beyond proximal tubule. calculated from $C_{Li}$ as a measure of inflow from proximal tubule is constant in spite of variations in $C_{Li}$. (b) The $FrH_2O$ calculated from $C_{Li}$ is dependent largely upon ADH rather than inflow from proximal tubule. (c) When there is a decrease in plasma $Na^+$ concentration or ineffective body fluid. $Li^+$ reabsorption may occur in the thick segnent of Henle's loop and hence the determination of $Fr_{Na}$ and $FrH_2O$ will not be easy one, but $Fr_{Na}$ is constant under the same experimental conditions.

  • PDF

Research on Improvement of Lake Water Quality Using Artificial Floating Island (호소 수질 개선을 위한 인공식물섬 장치 개발 연구)

  • Kim, Tae-Hoon;Ahn, Tae-Woong;Jung, Jae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.263-270
    • /
    • 2010
  • This is a research on development of water purification equipment called artificial floating island (=AFI) for the stagnant water area which can secure exuberant landscape and water-friendility. The equipment devised in this study is designed to make up the weakness of conventional AFIs and improves the removal efficiency of pollutants using the mixture of media and plants. The air compressor positioned at the inlet releases air with inflow continuously, the water pump at the outlet sprays as a form of fountain with causing a disturbance on stable water column, then, both of them contribute improvement of water quality over a large area. We applied Bio-stone as a media in this system and performed an experiment of pre-efficiency test, and we concluded that the higher pollutants concentration of inflow, the higher removal efficiency we obtained. At the result of lab-scale experiment, in the case of high-concentration inflow, in the removal efficiency of SS is 62.2%, BOD is 50.2%, COD is 55.1%, T-N is 31.6%, T-P is 38.4%. In addition, to evaluate the field application, we set up the facilities in Sin-gal lake located in Yongin-Si Gyeonggi-Do, and researched on the removal efficiency of outflow relative to the inflow. As a result, SS is 53.5%, BOD is 32.8%, COD is 36.9%, T-N is 22.6%, T-N is 33.2%.

A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR (침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구)

  • Choi, Yong-Bum;Lee, Hae-Seung;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7227-7236
    • /
    • 2015
  • The survey revealed that, due to the discharge characteristics of seafood wastewater, irregular inflow loads were caused, making it difficult to treat the wastewater safely. It is crucial for the operation of pressure and floating tanks for the treatment of high-concentration organic wastewater such as seafood wastewater. The survey of operation factors for the pressure and floating tanks revealed this: A/S ratio 0.05 (design criteria 0.01), the pressurized air pressure 8bar(design criteria 6bar), the pressure tank pressure 6bar (design criteria 4.5bar), and HRT 60sec(design criteria: 10sec). Also, the recirculation rate was changed to over 40%(design criteria: 30%), and the surface load rate was changed to under $13.7m^3/m^2{\cdot}hr$(design criteria: under $17.7m^3/m^2{\cdot}hr$); thus, compared to the initial design criteria, the operation factors were changed according to inflow characteristics, thus enhancing the pressure and floating tank performance. The survey of inflow load revealed BOD 140.7%, $COD_{Mn}$ 120.32%, and SS 106.3%, compared to the inflow design criteria, as well as T-N 135.5% and T-P173.3%, higher than the design criteria. The survey of the treatment facility annual operation cost revealed high portions in sludge treatment cost(27.7%) and chemicals costs(26.0%), and the sludge treatment cost will likely further increase due to the ban on ocean dumping. The unit cost for the treatment of seafood wastewater was found to be KRW 3,858 per ton, more than 27 times higher than the sewage treatment cost(KRW 142.6/ton), presumably because the seafood wastewater contains high-concentration organic substances and nutritive salts.

Material Budgets in the Youngsan River Estuary with Simple Box Model (영산강 하구해역에서의 단순 박스모델에 의한 물질수지)

  • Lee, Kyeong-Sig;Jun, Sue-Kyung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.248-254
    • /
    • 2009
  • Budgets of fresh water, salt, DIP and DIN in the Youngsan river estuary were estimated seasonally in order to clarify the characteristics of material cycling and flux of nutrients with a simple box model. Inflow volumes of freshwater into system was approximately $36.481{\times}10^6{\sim}663.634{\times}10^6m^3/month$ and existing water mass of freshwater in system calculated by salt budget was approximately $2.515{\times}10^6{\sim}5.812{\times}10^6m^3$. Mean residence time of freshwater was calculated to be about 0.26~2.03 day. water exchange $1,248{\times}10^6{\sim}9,489{\times}10^6m^3/month$ assumed with salinity between estuary and adjacent ocean. Inflow mass of DIN and DIN were approximately 76.63~1,149.91 ton/month and 2.91~61.22 ton/month, respectively. Residence times of DIP and DIN were calculated to be 0.45~1.10 day and 0.28~1.92 day, respectively. The ratio of water residence time versus DIP, DIN residence time was calculated that freshwater residence time was longer than DIP, DIN residence time except for summer season. Thus, We assume that circulation of Nutrients in the system will happen rapidly except for summer season. Specially DIP in Winter could assume to outer input source existence because of seawater inflow in system and high DIP concentration in open sea.

  • PDF

Impact of Seawater Inflow by the Operation of Sluice Gates on the D.O and pH in the Lake Shihwa, Korea (시화호 배수갑문 운용에 따른 용존산소와 pH 변화)

  • Choi, Jung-Hoon;Kim, Mi-Ock
    • Journal of the Korean earth science society
    • /
    • v.22 no.3
    • /
    • pp.195-207
    • /
    • 2001
  • The variations of D.O and pH due to the inflow of seawater by sluice gates operation were observed in the Lake Shihwa, Korea. The distributions of D.O and pH were investigated at 11 stations during Feburary 1997 to July 1998. The concentration of D.O before gate operation was 10 mg/l or more all over the watershed, yet 5 mg/l or less in the water layers of 11 m or below from March to June 1997. Anoxic layer appeared in June 1997 and expanded during rainy season. The anoxic layer in the lake depleted the oxygen in seawater as seawater was inflowed. It may be interpreted that the phenomenon comes from the contact of seawater to lower fresh water. The contact of seawater in pH 7.8 to 8.2 to lower water less than pH 7.4 enhanced to oxidize. After January 1998, D.O of the lake increased over 10 mg/l and the stratification was weakened. As a result, it may be concluded that the best way to improve the water qualities is to increase the amount of seawater inflow and outflow so as not to be generated pycnocline in summer.

  • PDF

Analysis of Change Transitions in Regional Types in Emergency Department Patient Flows of in Jeonlado (2014-2018) (전라지역 응급실 환자의 유출입 분석 및 지역유형 변화 추이)

  • Lee, Jae-Hyeon;Lee, Sung-Min;Kim, Seongjung;Oh, Mi-Ra
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.126-131
    • /
    • 2020
  • This study analyzed the inflow and outflow patterns of emergency department patients, to identify changes in regional types in cities, counties, and districts in Jeonlado, Korea. Data of areas in Jeonlado for 2014 to 2018 were extracted from the National Emergency Department Information System. The extracted data includes the patients' and emergency medical institution addresses, which were used to calculate the relevance index (RI) and commitment index (CI). The calculated indices were classified into regional types by applying cluster analysis. A non-parametric method, Kruskal-Wallis test, was employed to examine the differences between years for RI and CI by regional types. The results of cluster analysis using the relevance and commitment indices revealed three regional types. Regions in cluster 1 were classified as outflow type, in cluster 2 as inflow type, and in cluster 3 as self-sufficient. RI and CI were calculated for each cluster or regional type. There were no significant differences between years in cluster 2 (inflow type) and cluster 3 (self-sufficient type). In cluster 1 (outflow type), there were no significant differences in CI between the years; however, there were significant differences in RI between 2014 and 2017, and 2014 and 2018. It is difficult to see that the emergency medical environment has improved due to the increased concentration of emergency medical care.

Water Quality Fluctuation Study of Paldang Reservoir Affected by Gyeongan Stream Inflow according to Rainfall (강우기 및 비강우기 경안천 수체흐름에 의한 팔당호 수질변동 비교 평가)

  • Heo, Seong-Nam;Noh, Hye-Ran;Yang, Hee-Jeong;Jeong, Dong-Il;Kim, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.236-244
    • /
    • 2006
  • Water quality fluctuation of Gyeongan water area in Paldang reservoir, which measured from the downstream sampling point of Gyeongan stream (G1) to dam sampling point (P), was examined in the light of seasonal rainfall and regional difference in the year of 2002. Annual COD, T-P and T-N concentration dropped conspicuously at the point P (in front of dam) although concentration of Gl point was high. Concentration variation of COD, T-P and T-N from Gl to P point in Gyeongan area was small in August and September. And at G l point showed relatively low concentration. Chlorophyll-a concentration varies less during the autumn season (October to December) than spring season (March to June). Water temperature of Bughangang (north Han-river) area was relatively lower in August and higher in November compared with that of other areas. COD and SS concentration showed big regional difference except in November when the concentrations of which were relatively low. The high Chlorophyll-a concentration of April fell conspicuously in rainy season. Gyeongan area, where the water depth is relatively shallow, indicated steep temperature gradient in April compared with that in August or November. High 55 concentration in April at P point characterized surface layer while the opposite was recorded in August. Mixing of upper and lower layers had taken place causing dilution of COD, T-N and T-P concentration in August. This condition was maintained throughout November. Therefore, spring-summer seasons needed more attention for water management countermeasure than summer-autumn seasons.

The Effect of Freshwater Inflow on the Spatio-temporal Variation of water Qualify of Yeongil Bay (영일만 수질의 시ㆍ공간 변동에 미치는 담수유입의 효과)

  • 김영숙;김영섭
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • In order to determine the effect of fresh water inflow from the Heongsan river on the changes of water quality in the Yeongil Bay (Korea), the seasonal changes of water temperature, salinity, chemical oxygen demand (COD), dissolved inorganic nitrogen(DIN) and phosphate phosphorus ($PO_4$-P) concentrations were examined using the data set obtained five fixed points of Yeongil Bay from 1998 to 2000. The distributions and changes of COD and concentrations of total inorganic phosphorous (TIP) and nitrogen (TIN) at three points Heongsan river, were also compared with those of Yeongil Bay. Based on the correlations of DIN and $PO_4$-P, it was found that the inflow of freshwater affected on the water quality of Yeongil Bay. Such a complicacy was confirmed by the prominent differences in n few water quality measures between Site 1(the innermost area) and Site 5 (the mouth of the bay). The negative correlations in $\Delta N/\Delta P $ at sites 1, 2 and 3 of the inner-part of the bay also indicated a large effect of freshwater inflow on the water quality of the bay. The extremely low atomic ratio of an average of 6.4 in $\Delta N/\Delta P $ compared to the Redfild ratio suggested that the DIN was depleted in the overall bay system. In contrast, it was inferred that the excessive PO$_4$-P concentration was due to the inflow of freshwater from the Heongsan river.

Estimation of Water Quality Variation in Sewer Network using MOUSE TRAP Model (MOUSE TRAP 모델을 이용한 하수관거내 수질변화 예측)

  • Yang, Hae Jin;Jun, Hang Bae;Son, Dae Ik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.743-752
    • /
    • 2009
  • One of the major problems associated with operation of domestic sewer lines involves hydraulic problems such as insufficient conveyance capacity, exceeding maximum velocity, and deficiency of minimum velocity. It has also been pointed out that influent concentration lower than design concentration of pollutants, which is mainly caused by unidentified inflow and infiltration, degrades the operational efficiency of many sewage treatment plants (STPs). A computer-added analysis method supporting a coupled simulation of sewage quality and quantity is essentially required to evaluate the status of existing STPs and to improve their efficiency by a proper sewer rehabilitation work. In this study, dynamic water quality simulations were conducted using MOUSE TRAP to investigate the principal parameters that governs the changes of BOD, ${NH_4}^+$, and ${PO_4}^{3-}$3- concentrations within the sewer networks based on data acquired through on-site and laboratory measurements. The BOD, ${NH_4}^+$ and ${PO_4}^{3-}$3- concentrations estimated by MOUSE TRAP was lower than theoretical pollution loads because of sedimentation and decomposition in the sewer. The results revealed that sedimentation is a most important factor than other biological reactions in decreasing pollutant load in the sewers of C-city. The sensitivity analysis of parameters pertaining to water quality changes indicated that the effect of the BOD decay rate, the initial DO concentration, the half-saturation coefficient of dissolved BOD, and the initial sediment depth is marginal. However, the influence of settling rate and temperature is relatively high because sedimentation and precipitation, rather than biological degradation, are dominant processes that affect water quality in the study sewer systems.

Removal Characteristics of Nitrogen Oxides (NOx) in Low Concentration using Peat-Mixed Media (피트(peat) 혼합담체를 이용한 저농도 질소산화물(NOx) 제거특성)

  • Kang, Young-Heoun;Kim, Deok-Woo;Kang, Seon-Hong;Kwon, Pil-Joo;Kim, Dal-Woo;Hwang, Pil-Gi;Shim, Sang-Bo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.330-338
    • /
    • 2010
  • In this study, removal characteristics of nitrogen oxides $(NO_x)$ from road transport by using peat as the packing media for biodegradation have been investigated in the long term. Physicochemical and biological treatment of peatmixed media eliminates any requirement to use chemical substances and also facilitates the biodegradable actions of microorganism. Safe biodegradation of pollutants, no need to apply additional microbes owing to their active growth, and no generation of secondary pollutants were found in this experiment. It was concluded that average removal efficiencies of nitric oxide (NO) and nitrogen dioxide $(NO_2)$ were 80% and 97% respectively with respect to the linear velocity 35~40 mm/s and 0.3 ppm ozone concentration in the long period operation. Inflow concentration of nitric oxide over 0.05 ppm was suitable when pretreated with ozone. Non-ozone stage was performed with linear velocity 20~100 mm/s and then the average removal efficiency of nitric oxide and nitrogen dioxide were 38% and 94% respectively. Other results showed that the apparent static pressure was raised with increases in applied water content and aerial velocity in mixed media during fan operation.