• Title/Summary/Keyword: inert gas

Search Result 384, Processing Time 0.024 seconds

Influence of Inert Gas on the Configuration Characteristics of Premixed Turbulent Propagating Flames of Hydrogen Mixtures (수소 예혼합 난류전파화염의 화염형상 특성에 미치는 불활성 가스의 영향)

  • 나까하라마사야;키도히로유끼;김준효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.632-640
    • /
    • 2004
  • The purpose of this study is to clarify the influence of inert gas on the configuration characteristics of premixed turbulent propagating flames of hydrogen mixtures. Inert gas is changed to $N_2$, Ar, $CO_2$ and He keeping the laminar burning velocity of mixtures nearly the same value. A laser tomography technique was used to obtain the flame shape, and quantitative analyses were performed. The result shows that in the wrinkled laminar flame region, the surface area of turbulent flame is slightly dependent on the equivalence ratio and the kind of inert gas. It is also shown the region of convex part of flame toward the unburned gas is greater than that of toward the burned gas regardless of the kind of inert gas.

Performance Analysis of an Inert Gas Generator for Fire Extinguishing

  • Kim, Su-Yong;Arkadiy F. Slitenko
    • 연구논문집
    • /
    • s.29
    • /
    • pp.5-15
    • /
    • 1999
  • Present study deals with performance analysis of an inert gas generator (IGG) which is to be used as an effective mean to suppress the fire. The IGG uses a turbo jet cycle gas turbine engine to generate inert gas for fire extinguishing. It is generally known that a lesser degree of oxygen content in the product of combustion will increase the effectiveness of fire suppressing. An inert gas generator system with water injection will bring advantages of suffocating and cooling effects which are considered as vital factors for fire extinguishing. As the inert gas is injected to the burning site, it lowers the oxygen content of the air surrounding the flame as well as reduces the temperature around the fire as the vapour in the inert gas evaporates during the time of spreading. Some important aspects of influencing parameters, such as, air excess coefficient. $\alpha$, compressor pressure ratio, $ pi_c$, air temperature before combustion chamber, $T_2$, gas temperature after combustion chamber, $T_3$, mass flow rate of water injection, $M_w$, etc., on the performance of IGG system are investigated. Calculations of total amount of water needed to reduce the turbine exit temperature to pre-set nozzle exit temperature employing a heat exchanger were made to compare the economics of the system. A heat exchanger with two step cooling by water and steam is considered to be better than water cooling only. Computer programs were developed to perform the cycle analysis of the IGG system and heat exchanger considered in the present study.

  • PDF

A study on the improvement of coating film characteristic in arc spraying by using the inert gas (아크용사시 불활성가스에 의한 피막밀착강도 향상에 관한 연구)

  • 김영식;여욱종
    • Journal of Welding and Joining
    • /
    • v.5 no.2
    • /
    • pp.17-26
    • /
    • 1987
  • In this study, the experiments were carried out for the purpose of establishment of the arc sparing method which reducing oxides or oxide film by using the inert gas as the carrier gas of atomizing particles. Main results obtained are as follows; 1. Oxides and oxide film which lower the adhesion strength are largely reduced by using the inert gas as the carrier gas of atomizing particles, and adhesion strength of coating film are improved. 2. The coating film characteristics appear to be no difference between the inert gas arc spraying in air environment and that in argon gas environment. 3. Inert gas arc spraying using argon as the carrie gas has higher reduction rate of composition element in coating film than compressed air spraying does.

  • PDF

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

A Study of the Application of Inert Gas Generator to the Fire Extinguishing System (불활성 가스 발생장치(Inert Gas Generator) 소화시스템 적용에 관한 연구)

  • Han Yong-Shik;Kim Myoung-Bae;Kim Su-Yong
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.69-74
    • /
    • 2005
  • A study of the utilization of inert gas generator(IGG) that generates a large amount of inert gas for the fire extinguishing equipment was performed. In this study, the fire extinction performance of gas generated from a 1GG which is implemented to a gas turbine was investigated. A simulated mixture gas of which composition is the same as that of the gas generated from ICG was used in all experiments. First, the extinction concentration was measured using a cup burner method. The extinction design concentration and the volume of extinction space was calculated by applying the obtained extinction concentration to a method recommended by NFPA 2001. In practical respects, the fire extinction performance of IGG-generated gas was confirmed through the fire suppression experiment within a $2m\times2m\times2m$ room.

Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives (가스계 청정소화약제의 소화특성과 첨가제에 따른 영향)

  • Shin, Chang-Sub;Kim, Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

Analysis of Thermal Control Performance of Variable Conductance Heat Pipe with Axial Grooves (축방향 그루브형 가변전열 히트파이프의 열제어 특성)

  • Park, Y.S.;Kim, D.E.;Byon, G.S.;Suh, J.S.;Lee, K.W.;Park, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1651-1656
    • /
    • 2003
  • The present study has been conducted to analytically investigate the thermal control performance of variable conductance heat pipe(YCHP) with axial grooves. The condenser port of the YCHP is occupied by a inert gas in which the concentration of gas is varied with the operation temperature and the heat transport capacity is thus varied with the operating temperature due to the variation of inert gas concentration. In this study, numerical evaluation for the thermal control of the YCHP with axial grooves is made from the 1st order diffusion model that considers the diffusive expansion of inert gas by concentration gradient. Ammonia is used as a working fluid and Nitrogen as a control gas in the Aluminum tube. As a result, the thermal performance of YCHP based on diffusion model has been compared with that of YCHP from flat front model. Additionally, it is found that the concentration of inert gas is distributed in the condenser region of YCHP with axial grooves.

  • PDF

Assessment of gas production and electrochemical factors for fracturing flow-back fluid treatment in Guangyuan oilfield

  • Liu, Yang;Chen, Wu;Zhang, Shanhui;Shi, Dongpo;Zhu, Mijia
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.521-528
    • /
    • 2019
  • Electrochemical method was used for the fracturing flow-back fluid treatment in Guangyuan oilfield. After performing electrolysis, we found that the amount of $H_2$ gas produced by electrode was closely related to the combination mode of electrodes and electrode materials. Using an aluminium electrode resulted in a large $H_2$ production of each electrode combination, whereas inert anode and cathode materials resulted in low $H_2$ production. Then, the relationship between the gas production of $H_2$ and the treatment efficiency of fracturing flow-back fluid in Guangyuan oilfield was studied. Results showed that the turbidity removal and decolourisation rates of fracturing flow-back fluid were high when $H_2$ production was high. If the $H_2$ production of inert electrode was large, the energy consumption of this inert electrode was also high. However, energy consumption when an aluminium anode material was used was lower than that when the inert electrode was used, whereas the corresponding electrode combination production of $H_2$ was larger than that of the inert electrode combination. When the inert electrode was used as anode, the gas production type was mainly $O_2$, and $Cl_2$ was also produced and dissolved in water to form $ClO^-$. $H_2$ production at the cathode was reduced because $ClO^-$ obtained electrons.

Drying Characteristics of Fine Polymers in an Inert Medium Fluidized Bed (매체유동층에서 미세 고분자의 건조특성)

  • Kim, Og-Sin;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • The effects of inlet gas velocity (0.26-0.31 m/s), inlet gas temperature (315-353 K) and the mass ratio (0.1-0.4) of fine polymer (crosslinked poly methyl methacrylate beads) to inert medium particles on the drying rate of fine polymer in a 0.15 m-ID ${\times}$ 1.0 m-high inert medium fluidized bed dryer have been investigated. Crosslinked PMMA beads of 20 ${\mu}m$ (group C) were used as fine polymer, and glass beads of 590 ${\mu}m$ (group B) were used as the inert medium. The drying rate increases with increasing inlet gas temperature and velocity. However, the drying rate decreases slightly as the mass ratio of fine polymer to inert medium particles increases. The particle size distribution of dried fine polymers was mono distribution.