• Title/Summary/Keyword: industrial floor

Search Result 378, Processing Time 0.096 seconds

A Study on the Traditional Houses in Young Seo District of Kangwon-Do - Focused on the Floor Plan Types - (강원도(江原道) 영서지방(嶺西地方) 민가(民家)에 관한 연구(硏究) - 평면유형(平面類型)을 중심(中心)으로 -)

  • Ryu, Seung-Yong
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.345-353
    • /
    • 1997
  • The purpose of this study is to find out the distinct characteristics of the floor plan types of the traditional houses in Young Seo District of Kangwon-Do. In the light of this previous studies concerning Korean traditional houses the examination of the natural environment and socio-cultural environment on the house form in terms of the floor plan types.

  • PDF

A Study on the Design and Development of Shop Floor Control Information System (Shop Floor Control 정보시스템 설계 및 개발 연구)

  • 한성배;조현규;박상봉
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.47-60
    • /
    • 1997
  • Today, more and more information is processed in the shop floor The main function of the shop floor is more enlarged and enriched by the integration of information processing tasks. So, we have designed the shop floor control information system(SFCIS) considered using the IDEF methodology. The SFCIS consists of 5 sub-systems, which are the manufacturing data base, the order release, the dynamic scheduling, the process control, and the output analysis sub-system. And we have constructed the SFCIS for long-cycle products, which have production lead time longer than the period of production planning horizon.

  • PDF

Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements” (바닥충격음 차단성능 평가방법의 KS 규격화 방안)

  • 송민정;장길수;김흥식;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF

A Study of Standardization of Floor Slip Test method using O-Y·PSM (경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구)

  • Shin, Yun-Ho;Kang, Yong-Hak;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

Which is Your Favorite?: The Impact of Robot's Height on Consumer's Acceptance of a Telepresence Robot

  • Choi, Jung Ju;Kwak, Sonya S.
    • Design Convergence Study
    • /
    • v.15 no.4
    • /
    • pp.59-70
    • /
    • 2016
  • Due to the newly emerging market for telepresence robots and the research in the area, designers and developers lack guidelines for specifying the physical characteristics of telepresence robots. On the basis of the previous literature, we attempted to make a distinction between two robot height approaches for telepresence robot designs: floor- versus desk-based robot designs. This research investigated the effects of these robot height approaches on consumer acceptance. We predicted that there would be difference between floor-based robots and desk-based robots regarding consumers' evaluation of and intent to purchase social robots. A study using two types of robots was conducted with sixty university students. The results showed that participants perceived desk-based robots as more useful than floor-based robots. In addition, the participants evaluated desk-based robots more positively than floor-based robots. Purchase intention and willingness to pay also showed similar results as evaluation. The implications for the design of telepresence robots in terms of increasing acceptance of robots are discussed in detail.

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Evaluation on Low-floor Bus Package Layout from the Perspective of Universal Design

  • Kim, Sun-Woong;Kim, Ji-Yeon;HwangBo, Hwan;Hwang, Bong-Ha;Moon, Yong-Joo;Ji, Young-Gu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.659-669
    • /
    • 2011
  • Objective: The aim of this study is to suggest a package layout guideline for low-floor bus by interview with passengers and observations of their behavior. Background: Increasing attention has been introduced the low-floor bus to be more suitable for use by transportation handicapped. Complex issues are involved in providing comfortable services to all people. We are going to suggest package layout guidelines for more comfortable and suitable travel to all people. Method: The two times of survey and video observation sessions were conducted on low-floor buses in Seoul; (1) a finding of potential issues in the first session, (2) a confirming of issues from the last session. Results: The three of major issues were founded in this study; (1) difficulties in supporting body when standing, (2) difficulties in sitting on front wheel pan seat, (3) difficulties in passing through the aisle. Conclusion: There were clear differences between public and transportation handicapped in using some tools which are used for support body such as roof hand rails, side hand rails, and hand rail rings. Some of design problems were founded to improve from the perspective of ergonomics and universal design. Such differences and design guidelines have to be considered in bus design as well as commercial vehicle. Application: The proposed design guidelines can be used to development of low-floor bus and other public transportations.

Ability to Maintain Postural Control while Standing on Perturbed Surfaces (바닥면의 교란에 따른 자세균형능력의 변화)

  • Park, Sung-Ha;Lee, Seung-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.

Properties of Concrete for Industrial Floor using Mineral Admixtures (혼화재를 사용한 산업용 바닥 콘크리트의 물성 검토)

  • Kim, Yong-Ro;Gong, Min-Ho;Park, Jong-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • Recently, exposed concrete by machinery trowel is generally used in industrial floor such as warehouse. Also, concrete using only the cement has been mainly used except mineral admixture in order to secure surface abrasion resistance. However, in hot weather construction, it is causing a serious problem such as workability inhibition of trowel using only ordinary portland cement. Due to this, it was investigated the effect of application of fly-ash and ground granulated blast furnace slag on properties and abrasion resistance of concrete for industrial floor in this study. The result of this study, it was confirmed that fly-ash and ground granulated blast furnace slag can be used in concrete for industrial floor without affecting significantly the properties of concrete.

An intelligent planner of processing equipment for CSCW-based shop floor control in agile manufacturing

  • Kim, Hwajin;Cho, Hyunbo;Jung, Mooyoung
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.185-192
    • /
    • 1995
  • A common control model used to implement computer integrated manufacturing(CIM) is based on the hierarchical decomposition of the shop floor activities, in which supervisory controllers are responsible for all the interactions among subordinates. Although the hierarchical control philosophy provides for easy understanding of complex systems, an emerging manufacturing paradigm, agile manufacturing, requires a new control structure necessary to accommodate the rapid development of a shop floor controller. This is what is called CSCW(computer supported cooperative work)-based control or component-based heterarchical control. As computing resources and communication network on the shop floor become increasingly intelligent and powerful, the new control architecture is about to come true in a modern CIM system. In this paper, CSCW-based control is adopted and investigated, in which a controller for a unit of device performs 3 main functions - planning, scheduling and execution. In this paper, attention is paid to a planning function and all the detailed planning activities for CSCW-based shop floor control are identified. Interactions with other functions are also addressed. Generally speaking, planning determines tasks to be scheduled in the future. In other words, planning analyzes process plans and transforms process plans into detailed plans adequate for shop floor control. Planning is also responsible for updating the process plan and identifying/resolving replanning activities whether they come from scheduling or execution.

  • PDF