• Title/Summary/Keyword: inductively coupled plasma-mass spectrometry (ICP-MS)

Search Result 157, Processing Time 0.024 seconds

Determination of Trace Elements in Organic Tissues of Rat by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라즈마 질량분석기를 이용한 흰쥐 장기중의 극미량원소의 분석)

  • 강종성;김효진
    • YAKHAK HOEJI
    • /
    • v.37 no.6
    • /
    • pp.577-580
    • /
    • 1993
  • The trace elements in liver, kidney and testicle of rats were analysed by Inductively Coupled Plasma-Mass Spectrometer(ICP-MS). Ten elements(Cr, Ni, Cu, Zn, Mo, Cd, Pb, Bi, Th, U) were determined simultaneously and the detection limit of each elements was lower than ppb level.

  • PDF

Determination of Trace Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라즈마 질량분석기를 이용한 동물사료중의 극미량원소의 분석)

  • Park, Jeoung-Hwa;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.199-204
    • /
    • 1992
  • The trace elements in animal feed were analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS, VG-PlasmaQuad Co.) to find possible sources of heavy metals accumulation in rat organ. The study about spectral interference was performed by analysis of a background spectrum of ICP-MS. Recovery test using standard of Cd and Se (100 ppb) was found to be better than 90%. Twenty elements (Ca, Fe, Mg, Ti, Cr, Ni, Cu, Zn, Ba, Al, Mn, Pb, B, Ce, Bi, U, V, Cd, and W)are determined.

  • PDF

Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석)

  • Suh, Jungkee;Woo, Jinchoon;Min, Hyungsik;Yim, Myeongcheul
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

Comparison Study of Sensitivity Factors of Elements in Glow Discharge- & Inductively Coupled Plasma- Mass Spectrometry

  • Kim, Young-Sang;Plotnikov, M.;Hoffmann, Volker
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1991-1995
    • /
    • 2005
  • Sensitivity factors of elements by a glow discharge mass spectrometry (GD-MS) were intensively investigated and compared with a laser ablation inductively coupled plasma-mass spectrometry (ICP-MS). In case of copper matrix, the sensitivity factor by GD-MS generally decreases with the increase of the mass number of element. The details are a little different between each data measured by Faraday and multiplier detectors. The factor by a multiplier detector drastically decreases with the mass increase in the region of low mass as in Faraday detector’s case, but slowly in the high mass region. On the contrast, the sensitivity factor of solution standard by a conventional ICP-MS slowly increases with the increase of elemental mass number even though there are some exceptions such as gold and also the sensitivity factor by a laser ablation ICP MS generally increases with mass number of element in the specimen of glass type. In case of steel matrix, any definite trends could not be shown in the relationship between the GD-MS’s sensitivity factor and elemental mass.

Tandem laser-induced breakdown spectroscopy laser-ablation inductively-coupled plasma mass spectrometry analysis of high-purity alumina powder

  • Lee, Yonghoon;Kim, Hyang
    • Analytical Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.121-130
    • /
    • 2019
  • Alumina is one of the most important ceramic materials because of its useful physical and chemical properties. Recently, high-purity alumina has been used in various industrial fields. This leads to increasing demand for reliable elemental analysis of impurities in alumina samples. However, the chemical inertness of alumina makes the sample preparation for conventional elemental analysis a tremendously difficult task. Herein, we demonstrated the feasibility of laser ablation for effective sampling of alumina powder. Laser ablation performs sampling rapidly without any chemical reagents and also allows simultaneous optical emission spectroscopy and mass spectrometry analyses. For six alumina samples including certified reference materials and commercial products, laser-induced breakdown spectroscopy (LIBS) and laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) analyses were performed simultaneously based on a common laser ablation sampling. LIBS was found to be useful to quantify alkali and alkaline earth metals with limits-of-detection (LODs) around 1 ppm. LA-ICP-MS could quantify transition metals such as Ti, Cu, Zn, and Zr with LODs in the range from a few tens to hundreds ppb.

Determination of Rare Earth Elements Abundance in Alkaline Rocks by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) (ICP-MS를 이용한 알칼리암의 희토류원소 정량분석)

  • Hur, Soon-Do;Lee, Jong-Ik;Lee, Mi-Jung;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2003
  • Inductively coupled plasma mass spectrometry (ICP-MS) is useful instrument for determining abundance of rare earth elements, due to very low detection limits and rapid data acquisition. In this article, two methods are used for decomposition of alkaline rocks; close vessel acid digestion and $Na_2Co_3$ fusion. The two analytical results show good agreements. Considering total dissolved solids and detection limits, the most adequate dilution factor is 5,000 times. Polyatomic ion interferences during analysis can give rise to Inaccuracies. After correction from oxide and hydroxide interference, the analytical result show 20-30% decrease for Gd and Tm, 10-20% decrease for Tb and Er. In comparing the analytical results from KORDI with other institutes, most rare earth elements abundance show good agreements except Lu.

Chemical Speciation of Trace Metals in Natural Water by Ultrafiltration/Size Exclusion Chromatography/UV Absorption/ICP-MS

  • Haraguchi, Hiroki;Itoh, Akihide;Kimata, Chisen
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.405-410
    • /
    • 1995
  • A study on elemental speciation of trace metals in lake water (Lake Biwa in Japan) has been carried out by a size exclusion chromatography (SEC) / inductively coupled plasma mass spectrometry (ICP-MS) system. Before analysis, the water sample was preconcentrated with a ultrafiltration technique, where the large molecules with molecular weight larger than 10,000 were concentrated. Then the preconcentrated water samples (500-1000 fold) were analyzed by a SEC/ICP-MS system. Most trace metals were found at the UV absorption peaks corresponding to the molecular weights of ca. 300,000 and 10,000-50,000, where trace metals were on-line detected by ICP-MS. The results suggest that many of trace metals exist as the large organic molecules-metal complexes in natural water.

  • PDF

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR THE DETERMINATION OF 237Np IN SPENT NUCLEAR FUEL SAMPLES BY ISOTOPE DILUTION METHOD USING 239Np AS A SPIKE

  • Joe, Kihsoo;Han, Sun-Ho;Song, Byung-Chul;Lee, Chang-Heon;Ha, Yeong-Keong;Song, Kyuseok
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.415-420
    • /
    • 2013
  • A determination method for $^{237}Np$ in spent nuclear fuel samples was developed using an isotope dilution method with $^{239}Np$ as a spike. In this method, inductively coupled plasma mass spectrometry (ICP-MS) was taken for the $^{237}Np$ instead of the previously used alpha spectrometry. $^{237}Np$ and $^{239}Np$ were measured by ICP-MS and gamma spectrometry, respectively. The recovery yield of $^{237}Np$ in synthetic samples was $95.9{\pm}9.7$% (1S, n=4). The $^{237}Np$ contents in the spent fuel samples were 0.15, 0.25, and $1.06{\mu}g/mgU$ and these values were compared with those from ORIGEN-2 code. A fairly good agreement between the measurements (m) and calculations (c) was obtained, giving ratios (m/c) of 0.93, 1.12 and 1.25 for the three PWR spent fuel samples with burnups of 16.7, 19.0, and 55.9 GWd/MtU, respectively.

Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang;Cha, Myeong;Lee, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.205-209
    • /
    • 2001
  • Uniformly-doped silicon thin films were fabricated by ion beam sputter deposition. The thin films had four levels of copper dopant concentration ranging between 1 ${\times}$1019 and 1 ${\times}$ 1021 atoms/cm3 . Concentrations of Copper dopants were determined by the isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) to provide certified reference data for the quantitative surface analysis by secondary ion mass spectrometry (SIMS). The copper-doped thin films were dissolved in a mixture of 1 M HF and 3 M HNO3 spiked with appropriate amounts of 65 Cu. For an accurate isotope ratio determination, both the detector dead time and the mass discrimination were appropriately corrected and isobaric interference from SiAr molecular ions was avoided by a careful sample pretreatment. An analyte recovery efficiency was obtained for the Cu spiked samples to evaluate accuracy of the method. Uncertainty of the determined copper concentrations, estimated following the EURACHEM Guide, was less than 4%, and detection limit of this method was 5.58 ${\times}$ 1016 atoms/cm3.