• Title/Summary/Keyword: inductive coupling

Search Result 157, Processing Time 0.024 seconds

A Codeword Generation Technique to Reduce Dynamic Power Consumption in Tightly Coupled Transmission Lines (밀결합 전송선 상에서 전력 저감을 위한 코드워드 생성 기법)

  • Lim, Jae-Ho;Kim, Deok-Min;Kim, Seok-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.11
    • /
    • pp.9-17
    • /
    • 2011
  • As semiconductor process rapidly developed, the density of chips becomes higher and the space between adjacent lines narrows smaller. This trend increases the capacitance and inductance in interconnects and the coupling-capacitance of adjacent lines grows even bigger than the self-capacitance of themselves, especially in global interconnects. Inductive and capacitive coupling observed in these phenomena may cause serious problems in signal integrity. This paper proposes a codeword generation technique using extra interconnect lines to reduce the crosstalk caused by inductive and capacitive coupling and to reduce dynamic power consumption considering probability of input data. To estimate the performance of the proposed technique, the experimental results have been obtained using FastCap, FastHenry and HSPICE, and it has been shown that the power consumption using the proposed technique has yielded approximately 15% less than the results of the previous technique.

Receiving Characteristics of an Electronic Steering System according to the Change of the Coil Structure (전자식 조향 장치의 코일 구조 변화에 따른 수신 특성)

  • Park, Jae-Hong;Jeong, Gyu-Won;Ryu, Seung-Ryul;Kim, Eun-Ha;Choi, Han-Ol;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.868-874
    • /
    • 2011
  • In this paper, a new structure to improve the resolution of an inductive torque sensor is proposed. The new coupling structure and the change of number of turns for the receiving coil increase the resolution of the torque sensor. Because this torque sensor has non-contact points, it has no abrasion at the contact point, and is very durable. Also, the torque sensor has less variation due to vibration or strain, and it has a good EMC(Electromagnetic Compatibility) and thermal characteristics.

A Study on Power Stability Improvement in the Inductive Coupled RFID Transponder System

  • Kim, Gi-Rae;Choi, Young-Kyu
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.150-154
    • /
    • 2007
  • Transponders of RFID system are classified as active or passive depending on the type of power supply they use. In passive transponders the data carrier has to obtain its power from the induced voltage. The induced voltage is converted into direct current using a low loss bridge rectifier and then smoothed. In practice, the induced voltage in the transponder coil is variable according to the coupling coefficient k and the load resistance ($R_L$). Therefore, the rectified voltage is unstable and the transponder of RFID is unstable sometimes. In this paper, a voltage-dependent shunt resistor ($R_s$) circuits are designed and inserted in parallel with the load resistance of RFID transponder in order to improve the stability of power.

Implementation of an Inductively Coupled EM Probe System for PD Diagnosis

  • Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 2011
  • In recent years, various types of partial discharge (PD) methods such as capacitive, inductive, electromagnetic, and acoustic coupling techniques have been developed for diagnosing rotating machines. An electromagnetic (EM) probe, which is an inductively coupled type of sensor, is required for detecting corona and internal discharges during off-line tests. In this study, a new technique for enhancing the measurement sensitivities for corona and internal discharge based on an EM inductive position sensor is proposed. An EM probe that winds wires around horseshoe-shaped and cylindershaped ferrites as helices is designed and optimized for the implementation of off-line PD monitoring of the stator winding of a rotating machine. The measurement system based on this design is implemented, and it is verified from the results of the experiment performed in this study that the probe provides similar performance as existing commercial products.

Analysis of Inductive Interference from EHV Transmission to buried Gas Pipelines (초고압 송전선로에서 가스관에 미치는 유도 장해 해석)

  • Lee, Seung-Youn;Ko, Eun-Young;Yun, Suk-Moo;Park, Nam-Ok;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.458-460
    • /
    • 2000
  • In this paper, we analyze the inductive coupling between overhead power transmission lines and neighbouring gas pipelines or other conductors, when they parallel to a line section in a phase-to-earth fault is assumed on the transmission line. A numerical procedure employing the finite-element method(FEM) is used in conjunction with Faraday's law, in order to predict the current in a faulted transmission line as well as the induced voltages across points on a pipeline running parallel to the faulted line and remote earth. The results lead to conclusion that may be useful to power system engineers.

  • PDF

Signal Transient and Crosstalk Model of Capacitively and Inductively Coupled VLSI Interconnect Lines

  • Kim, Tae-Hoon;Kim, Dong-Chul;Eo, Yung-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.260-266
    • /
    • 2007
  • Analytical compact form models for the signal transients and crosstalk noise of inductive-effect-prominent multi-coupled RLC lines are developed. Capacitive and inductive coupling effects are investigated and formulated in terms of the equivalent transmission line model and transmission line parameters for fundamental modes. The signal transients and crosstalk noise expressions of two coupled lines are derived by using a waveform approximation technique. It is shown that the models have excellent agreement with SPICE simulation.

Time-Domain Analysis of Wireless Power Transfer System Behavior Based on Coupled-Mode Theory

  • Shim, Hyunjin;Nam, Sangwook;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.219-224
    • /
    • 2016
  • In this paper, coupled-mode theory (CMT) is used to obtain a transient solution analytically for a wireless power transfer system (WPTS) when unit energy is applied to one of two resonators. The solutions are compared with those obtained using equivalent circuit-based analysis. The time-domain CMT is accurate only when resonant coils are weakly coupled and have large quality factors, and the reason for this inaccuracy is outlined. Even though the time-domain CMT solution does not describe the WPTS behavior precisely, it is accurate enough to allow for an understanding of the mechanism of energy exchange between two resonators qualitatively. Based on the time-domain CMT solution, the critical coupling coefficient is derived and a criterion is suggested for distinguishing inductive coupling and magnetic resonance coupling of the WPTS.

Newly Designed Ion Beam Etcher with High Etch Rate

  • Cheong, Hee-Woon
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.366-370
    • /
    • 2015
  • New ion beam etcher (IBE) using a magnetized inductively coupled plasma (M-ICP) has been developed. The magnetic flux density distributions inside the upper chamber, where the plasma is generated by inductive coupling, were successfully optimized by arranging a pair of circular coils very carefully. More importantly, the proposed M-ICP IBE exhibits higher etch rate than ICP.

The Shielding Effectiveness Analysis of Power Cables Has Coaxial Structure Using Inductive Coupling Test (유도결합 실험을 통한 동축구조를 갖는 전력케이블의 차폐효과 분석)

  • Song, Euihyun;Lee, Keonbong;Nah, Wansoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1277-1278
    • /
    • 2015
  • 본 논문에서는 유도결합 실험을 통해 동축 구조를 갖는 전력케이블의 차폐효과에 대해 분석했다. 케이블의 차폐 도체의 재료에 따라 차폐 정도를 비교했고, 또한 주파수의 변화에 따른 차폐 정도를 비교했다. 측정 결과, 주파수가 증가할수록 차폐효과가 감소하는 것을 알 수 있었으며, 차폐 재질에 따라서도 차폐효과가 달라지는 것을 확인 할 수 있었다. 전달 임피던스를 통해 차폐효과를 분석한 실험의 결과와 비교를 통한 실험의 타당성도 보였다.

  • PDF

Analysis and Design of Asymmetric Coupled Line Directional Couplers for Microwave Integrated Circuits (마이크로파 집적회로(MIC)를 위한 비대칭 방향성 결합기의 해석과 설계)

  • 진연강
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.3
    • /
    • pp.298-308
    • /
    • 1987
  • It is shown that ideal directional couplers consisting of coupled asymmetric lines in an inhomogeneous medium can be realized equalizing the inductive and capacitive coefficients of coupling. Design procedures and examples of the couplers are presented.

  • PDF