• Title/Summary/Keyword: inductive coupling

Search Result 157, Processing Time 0.026 seconds

Change of Recognition Range According to Resonance Frequency of the 13.56MHz RFID Transponder (13.56MHz RFID 트랜스폰더의 공진 주파수에 따른 인식거리의 변화)

  • Yoon, Ki-Suk;Yang, Woon-Geun;Yoo, Hong-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.127-130
    • /
    • 2005
  • In this paper, we investigated the change of recognition distance according to the resonance frequency of the transponder for the ISO 14443 Type A 13.56MHz RFID(Radio Frequency IDentification) system. We made thirteen transponders of the same size. The dimension of the transponder is $84.65mm{\times}53.00mm{\times}0.45mm$. We measured the resonance frequency by means of an inductive coupling. The measured resonance frequencies were between 12.9MHz and 17.3MHz. We measured the maximum distances where the transponder's USN(Unique Serial Number) was recognized and the subcarrier was observed. The measurement results show that we can obtain good performance when the Type A transponder has the resonance frequency around 14.2MHz for the given case.

  • PDF

Quantitative identification of the fluxon-flow modes in a stack of intrinsic Josephson junctions of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+x}$ single crystals

  • Bae, Myung-Ho;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.9-12
    • /
    • 2003
  • We observed the splitting of the fluxon-flow branches in the current-voltage characteristics of serially stacked intrinsic Josephson junctions (IJJs) formed in $Bi_2$$Sr_2$$CaCu_2$$O_{ 8+x}$ single crystals in the long-junction limit. Stacks of IJJs were sandwiched between two Au electrodes deposited on the top and the bottom of the stack using the ‘double-side cleaving technique’. In all the samples studied, the branch splitting started occurring for a dense fluxon configuration around 2 T and became more distinct in a higher magnetic field range. This observation can be explained in terms of switching between different Josephson fluxon modes in resonance with the collective plasma oscillations induced by both inductive and capacitive coupling between stacked IJJs. This is the first detailed and quantitative identification of the coherent flux-flow modes in stacked..

  • PDF

Noisy Parameter Estimation of Noisy Passive Telemetry Sensor System using Unscented Kalman Filter (잡음환경에서 UKF를 이용한 원격센서시스템의 파라메타 추정)

  • Kim, Kyung-Yup;Yu, Dong-Gook;Choi, Woo-Jin;Lee, Kwan-Tae;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1787-1788
    • /
    • 2006
  • In this paper, a noisy passive telemetry sensor system using Unscented Kalman Filter (UKF) is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including IC chip has, the principle of inductive coupling was applied to the modelling of a passive telemetry sensor system (PTSS) and its noisy capacitive parameter was estimated by the UKF algorithm. Specialty, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization

  • PDF

Dynamical transition of Josephson vortex lattice in serially stacked ${Bi_2}{Sr_2}{CaCu_2}{O_{8+x}}$ intrinsic Josephson junctions

  • Myung-Ho;Hu-Jong
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.52-55
    • /
    • 2004
  • The inductive coupling theory in serially stacked $Bi_2$$Sr_2$$CaCu_2$$O_{8+x}$ intrinsic Josephson junctions predicts that the lattice structure of the Josephson vortices along the c axis gradually changes from the triangular to the rectangular lattice with increasing the vortex velocity. This lattice transition appears as voltage jumps or sub-branch splitting in the Josephson vortex-flow region of current-voltage characteristics (IVC). We report the IVC in external magnetic fields from 2 to 4 T. The stack, with the lateral size of 1.4${\times}$15 $u\m^2$, was fabricated by using the double-side cleaving technique. The sub-branches in the Josephson vortex-flow region, corresponding to a plasma propagation mode in serially coupled intrinsic Josephson junctions, were also observed in the range of 2∼4T. Switching from one branch to another in Josephson vortex-flow region suggests the structural transition of the moving Josephson vortex lattice.

  • PDF

Screening bonding wire and the wideband characterization to reduce crosstalk between high density bonding wires (고밀도 본딩와이어간의 혼신감소를 위한 차폐 본딩왕이어 및 광대역 해석)

  • 이상동;이해영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.92-98
    • /
    • 1996
  • parallel bonding wires separaated with a screeing bonding wire are proposed and characterized in order to redue mutual coupling and parasitics of high-speed and high-density device packaging. The mehtod of moments (MoM) with the incorporation of the ohmic loss has been used in a wide range of frequencies. From the calculated results, we have found that the screening bonding wire effectively reduces inductive and capacitive crostalk levels more than 3dB. the parasitic self inductance is also reduced more than 12% by the screening effect. Therefore, for a general VLSi package, the packaging density can be increased more than 30% using the screening bonding wire. This screeing bonding wire and the analysis can be effectively used to reduce crosstalk and increase packaging density of high density devices.

  • PDF

Passive Telemetry Sensor System using RLSE Based Real Time Estimation Technique with Optimal Forgetting Factor

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.515-520
    • /
    • 2004
  • In this paper, a passive telemetry RF capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including It chip has, the principle of inductive coupling was applied to the modeling of a passive telemetry RF capacitive humidity sensor system and its capacitance was estimatedd by the RLSE algorithm. Specially, by introducing the optimal forgetting factor, we showed that the accuracy of its estimation was improved even in the time varying system and also the convergence time was reduced.

  • PDF

A Study on Photoresist Stripping Using High Density Oxygen Plasma (고밀도 산소 플라즈마를 이용한 감광제 제거공정에 관한 연구)

  • Jung, Hyoung-Sup;Lee, Jong-Geun;Park, Se-Geun;Yang, Jae-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.95-100
    • /
    • 1998
  • A helical inductively coupled plasma asher, which produces low energy and high density plasma, has been built and investigated for photoresist stripping process. Oxygen ion density in the order of $10^{11}/cm^3$ is measured by Langmuir probe, and higher oxygen radical density is observed by Optical Emission Spectrometer. As RF source power is increased, the plasma density and thus photoresist stripping rate are increased. Independent RF bias power to the wafer stage provides a dc bias to the wafer and an ability to add the ion assisted reaction. At 1 KW of the source power, the coupling mechanism of the RF power to the plasma is changed from the inductive mode to the capacitive one at about 1 Torr. This change causes the plasma density and ashing rate decreases abruptly. The critical pressure of the mode change becomes larger with larger RF power.

  • PDF

Electromagnetic Simulation & Electrical.Optical Characteristics by Changing Ferrite Position in Antenna (안테나에서 페라이트 위치 변화에 따른 전자계 시뮬레이션과 전기적.광학적 특성)

  • Lee, Joo-Ho;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Myung-Hyun;Kim, Byung-Tack;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.816-820
    • /
    • 2008
  • The RF inductive discharge of inductively couples plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. Although most practical ICPs operate at 13.56 [MHz] and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. In an electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of RF matching systems and RF generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, We discussed simulation and experimental results when changing ferrite position in antenna.

Development of Real-time Wireless Heart beat measurement System Using Patch-type Pressure Sensor (패치형 압력센서를 이용한 휴대용 실시간 무선 맥박 측정 시스템 개발)

  • Park, Jae-Soon;Choi, Sang-Dong;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1231-1232
    • /
    • 2015
  • 본 연구는 정확한 혈압과 맥박을 측정하기 위해 L-C 공진을 이용한 압력센서 및 이를 측정하기 위한 측정시스템의 개발에 대한 연구로 기존의 인위적인 압력을 가하거나 침습형태가 아닌 인체 요골동맥에 패치형태로 센서를 부착하여 심장운동에 따른 요골동맥의 기계적 변화를 센서 내부의 커패시턴스 및 인덕턴스의 변화로 인한 공진주파수의 변화로 검출하였으며, 센서의 코일은 휴대용 무선 측정 시스템의 안테나와 Inductive Coupling을 이루어 무선전력전송이 이루어지며 센서를 통해 측정된 혈압 및 맥박은 LCD 디스플레이 및 오실로스코프를 통해 수치화 및 영상화 하였다.

  • PDF

Implantable Functional Electrical Stimulation with Inductive Power and Data Transmission System (유도전력전송방식의 이식형 기능적 전기자극)

  • Lee, Joon-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.97-106
    • /
    • 2007
  • Functional electrical stimulation (FES) has developed over the last 35 years to become a scientifically, technologically and clinically recognized field of interest in clinical medicine. FES has been applied to locomotion, grasping, ventilation, incontinence, and decubitus healing. However, all of these achievements illustrate the initial applications of FES; its true potential has not yet been realized. Recently, FES systems, which are miniaturized stimulation devices, have been utilized in the clinical setting. However, because the stimulating electrodes of the current FES devices are percutaneous electrodes, which are susceptible to wire breakage, and skin infection an implantable FES stimulating electrode has been introduced in the U.S. and Japan. In the present study, an external power supply method using radio frequency (RF) coupling and data transmission was developed for the control of the implantable FES device. In addition, we review the current understanding of FES devices and their application in clinical medicine.

  • PDF