• Title/Summary/Keyword: induced electric field

Search Result 454, Processing Time 0.037 seconds

A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation (방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF

Characteristics of Time-Changing Electric and Magnetic Fields at a High Voltage Laboratory (고전압 실험실에서 시변성 전자계의 특성)

  • 이복희;이경옥;안창환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.83-93
    • /
    • 1997
  • This paper deals with measurements and evaluation of the time-changing electric and magnetic fields at a high-voltage laboratory. The electromagnetic disturbances originate mainly from ground faults and on/off operations of electric power equipments. The electronic circuits and control devices are very sensitive to electromagnetic interferences. It is necessory to evaluate the levels of interferences for a given electromagnetic environment. The electric field was observed by the electric field sensor having the bandwidth of the range from 40 Hz to 200 MHz, and the time-changing magnetic field was measured by the loop sensor of which the output is directly proportional to the incident signal. Also, the frequency components of the time-changing electric and magnetic fields induced by an oscillatory transient current and a chopped impulse voltage were analyzed by terms of the fast Fourier transformation, and those give the information about the levels of the electromagnetic interferences and the design of the electromagnetic shielding enclosures.

  • PDF

Analysis of the Rotational Magnetic Field using the FEM and the 2-Dimensional Permeability Tensor (유한 요소법과 이차원 텐서를 이용한 회전자계의 특성 해석)

  • Lee, Chang-Hwan;Kim, Hong-Kyu;Jung, Hyun-Kyo;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.169-171
    • /
    • 1996
  • Recently, the finite element analysis(FEM) using two dimensional magnetic permeability tensor was introduced to calculate the magnetic field considering the rotational hysteresis. We obtain the tensor matrix from the measured data using two-dimensional magnetic measuring apparatus. We calculate the induced magnetic flux density and the rotational hysteresis loss under the model with the same condition with the measuring apparatus. Therefore we show that FEM with tensor can be used to calculate the magnetic flux density and the rotational hysteresis loss in the arbitrary rotational magnetic field.

  • PDF

Experiment and Prediction of Nonlinear Behavior at High Temperatures of Ferroelectric Ceramics Switched by Electric Field at Room Temperature

  • Ji, Dae Won;Kim, Sang-Joo
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.235-242
    • /
    • 2017
  • Changes in polarization and thermal expansion coefficients during temperature increase of a poled lead zirconate titanate (PZT) cube specimen switched by an electric field at room temperature are measured. The measured data are analyzed to construct governing differential equations for polarization and strain changes. By solving the differential equations, an experimental formula for the high temperature behavior of ferroelectric materials is obtained. It is found that the predictions by the formula are in good agreement with measures. From the viewpoint of macroscopic remnant state variables, it appears that the processes of electric field-induced switching at different temperatures are identical and independent of temperature between $20^{\circ}C$ and $110^{\circ}C$.

Electric Field Induced Super-cooling System for Long Term Dry-aged Beef Loin

  • Park, Sin-Young;Kim, Hack-Youn
    • Food Science of Animal Resources
    • /
    • v.40 no.2
    • /
    • pp.286-296
    • /
    • 2020
  • This study investigates the utilization of an electric-field-induced super cooling system in long-term dry aging of beef loin. Analyzed quality properties of dry-aged beef loin applied with electric field refrigeration (EFR) versus commercial refrigeration (CR). Quality properties was including aging loss, pH, water holding capacity (WHC), cooking loss, color, warner-bractzler shear force (WBSF), total plate count (TPC), and thiobarbituric acid reactive substances (TBARS). Aging loss of wk 1 EFR was significantly lower than CR (p<0.05). pH of EFR was slow change tendency compared CR. WHC of both aging methods were higher with increase in aging duration. Cooking loss of wk 1, 2, 4, and 10 EFR were significantly lower than CR (p<0.05). Lightness and redness of EFR was slow change tendency compared CR. However, yellowness of EFR was increased until wk 2, 3, and significantly decreased at wk 10 (p<0.05), but yellowness of CR was decreased until wk 3 and significantly increased with an increasing aging weeks (p<0.05). Both aging methods of WBSF was decreased with increase in aging weeks; however, wk 10 of CR was significantly lower than EFR (p<0.05). TPC after wk 3 EFR groups were significantly lower than CR groups (p<0.05), and TBARS of EFR groups were significantly lower than CR (p<0.05). The present results show that application of the EFR system for dry aging beef loin can extends its shelf life and induce changes of several aging properties in similar to commercial aging.

Dielectrophoresis for Control of Particle Transport: Theory, Electrode Designs and Applications (입자 이동 제어를 위한 유전영동: 이론, 전극 구조 및 응용분야)

  • Lee, Minji;Kim, Ji-Hye;Koo, Hyung-Jun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.149-163
    • /
    • 2019
  • Under non-uniform electric field, a directional force along the electric field gradient is applied to matter having permanent or induced dipoles. The transport of particles by the directional force is called dielectrophoresis (DEP). Since the strength and direction of the DEP force depend on parameters, such as permittivity and conductivity of particles and surrounding media, and frequency of the applied AC electric field, particle can be precisely manipulated by controlling the parameters. Moreover, unlike electrophoresis, DEP can be applied to any particles where dipole is effectively induced by electric field. Such a DEP technique has been used in various fields, ranging from microfluidic engineering to biosensor and microchip research. This paper first describes the fundamentals of DEP, and discusses representative microelectrode designs used for DEP study. Then, exemplary applications of DEP, such as separation, capture and self-assembly of particles, are introduced.

Electric-Field-Induced Strain Measurement of Ferroelectric Ceramics Using a Linear Variable Differential Transducer (선형 가변 차동 변압기를 이용한 강유전 세라믹의 전기장 인가에 따른 변형 측정)

  • Hyoung-Su Han;Chang Won Ahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.2
    • /
    • pp.141-147
    • /
    • 2024
  • The measurement of strain under an electric field has been widely employed to comprehend the fundamental principles of electro-mechanical responses in ferroelectric, piezoelectric, and electrostrictive materials. In particular, understanding the strain properties of piezoelectric materials in response to electrical stimulation is crucial for researching and developing components such as piezoelectric actuators, acoustic devices, and ultrasonic generators. This tutorial paper introduces the components and operational principles of the linear variable differential transducer (LVDT), a widely used displacement measurement device in various industries. Additionally, we present the configuration of an experimental setup using LVDT to measure the strain characteristics of ferroelectric, piezoelectric, or electrostrictive materials under the application of an electric field. This paper includes simple measurement results and analyses obtained through the LVDT experimental setup, providing valuable information on research methods for the electro-mechanical interactions of various materials.

A Comparative Study Between Diffusive-thermal and Buoyancy-driven Self-excitations in Laminar Free Jet Flames with Applied DC Electric Fields (직류전기장이 인가된 층류제트화염에서 물질 -열 확산과 부력에 의한 진동비교에 관한 연구)

  • Han, Jong-Kyu;Yoon, Sung-Hwan;Park, Jeong;Kwon, Oh-Boong;Kim, Tae-Hyung;Park, Jong-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.37-47
    • /
    • 2012
  • Experimental study on comparison of diffusive-thermal self-excitation with buoyancy-driven one due to accumulation of partially premixed, preheated mixture in front of edge flame was conducted in horizontally and vertically injected laminar free-jet flames with an applied DC electric field of -10 kV. The application of horizontal injection method with the DC electric field to jet flames was experimentally designed to suppress heat-loss-induced self-excitation and thereby to highlight the definite difference between both diffusive-thermal and buoyancy-driven self-excitations with the same order of O(1.0 Hz), in that diffusive-thermal self-excitation has not been so far found experimentally in laminar jet flames. Flame stability maps in vertically and horizontally injected jet flames are presented. The distinct modes of individual self-excitation are shown to be well described by their own phase diagrams. The results show that buoyancy-driven self-excitation due to the accumulation of partially premixed, preheated mixtures in front of edge flame is branched from the buoyancy-induced self-excitation with O(10 Hz) due to a flame flicker. Once the buoyancy-driven self-excitation appears, it suppresses buoyancy-induced as well as diffusive-thermal self-excitation. The key characteristics for individual self-excitation are discussed and their functional dependencies of Strouhal number upon related physical parameters are also presented.

Simulataneous X-ray Diffraction Measurements of the Antiferroelectric-ferroelectric Phase Transition of PLZT under Electric Field (전장하에서 PLZTd의 반강유전-강유전 상전이의 동시적 X-선 회절 측정)

  • 고태경;조동수;강현구
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.11
    • /
    • pp.1292-1300
    • /
    • 1996
  • In-site X-ray diffraction measurements under electric field up to 20kV/ cm were carried out on PLZT (x/70/30) with x=7.5, 8.0, 8.5, and 10.5 All of PLZT belonged to cubic phases. At x=7.5, 8.0 and 8.5 PLZT behaved as an antiferroelectric under low electric fields up to 4-8 kV/cm. PLZT became ferroelectric at the higher electric fields. The high-temperature measurements on the dielectric constants of PLZT with x=7.5, 8.0 and 8.5 showed that they were similar to relaxor ferroelectrics and underwent a diffuse phase transition from antiferroelectrics to paraelectrics at 50-7$0^{\circ}C$. Their P-E hysteresis curves confirmed that they were antifer-roelectrics. The broad distribution of Curie points suggests that there is a significant disorder of cations and vacances in the crystal structure of those PLZT due to La-substitution. The variation of the lattice strain of PLZT(10.5/70/30) with electic field was very small and did not show any hysteresis confirming that it was paraelectric. The degree of the electric-induced strain variation decreased as La doping increased. In PLZT(7.5/70/30) the intensity of 110 reflection changes sensitively by applying electric field. Some domains with polarization parallel to [110] appeared to be developed in the field-induced ferroelectric phase of the PLZT.

  • PDF