• Title/Summary/Keyword: induced electric field

Search Result 454, Processing Time 0.029 seconds

Pulse electric field-excited electron emission from Pb$(Zr_xTi_{1-x})O_3$ ceramics prepared by conventional solid state reaction (고상 반응법에 의해 제조된 Pb$(Zr_xTi_{1-x})O_3$ 세라믹스에서 펄스 전계에 의한 전자 방출)

  • Kwak, Sang-Hee;Kim, Tae-Heui;Park, Kyung-Bong;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1867-1869
    • /
    • 1999
  • Pulse electric field induced electron emission from ferroelectrics has been studied with Pb$(Zr_xTi_{1-x})O_3$ ceramics with varying Zr/Ti ratio from 35/65 to 65/35, Electron emission was proved to be concentrated on the electrode edge by emission profile test and emission capture photographs. The 65/35 composition showed largest emission charge in lowest field and lowest emission threshold field. The emission characteristics are closely dependent on their ferroelectric properties in hysteresis curve. Electron emission charge increases with the polarization charge and emission threshold voltage is dependent on coercive field regardless of their composition. But dielectric constant has little relation with emission property. Electron emission charge increases exponentially with pulse electric field irrespective of composition. On the assumption that the surface potential is linear with the pulse electric field, electron emission can be regarded as a field emission at the electrode edge using Fowler-Nordheim plot of ln$(Q_e/E_{fe})$ to $1/E_{fe}$.

  • PDF

An Analysis of Insulation Performance Result from Shield of Outside Vacuum interrupter (진공인터럽터 외부쉴드가 절연성능에 미치는 영향 분석)

  • Yoon, Jae-Hun;Lim, Gee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.100-100
    • /
    • 2010
  • Because of power consumption increase, global wanning, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. To improve the insulation performance, the high E field concentration phenomena was considered. Breakdown mechanism in vacuum is different from that in other insulation materials. therefore, It is necessary to understand the electric field distribution and insulation characteristics. This paper discusses the simulation and LI(light impulse) test of the shield of outside vacuum interrupter As a result, FEM simulation and LI test show that improve distribution of electrical field and equi-potential line. due to external shield. in this case, outside shield induced electric field of triple junction point.

  • PDF

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.

Effects of 60-Hz Time-Varying Electric Fields on DNA Damage and Cell Viability Support Negligible Genotoxicity of the Electric Fields

  • Yoon, Yeo Jun;Li, Gen;Kim, Gyoo Cheon;Lee, Hae June;Song, Kiwon
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.134-141
    • /
    • 2015
  • The effect of a 60 Hz time-varying electric field was studied using a facing-electrode device (FED) and a coplanar-electrode device (CED) for further investigation of the genotoxicity of 60 Hz time-varying magnetic field (MF) from preceding research. Neither a single 30-minute exposure to the CED or to the FED had any obvious biological effects such as DNA double strand break (DSB) and apoptosis in cancerous SCC25, and HeLa cells, normal primary fibroblast IMR90 cells, while exposures of 60 Hz time-varying MF led to DNA damage with induced electric fields much smaller than those used in this experiment. Nor did repetitive exposures of three days or a continuous exposure of up to 144 hours with the CED induce any DNA damage or apoptosis in either HeLa or IMR90 cells. These results imply that the solitary electric field produced by time-varying MF is not a major cause of DSBs or apoptosis in cancer or normal cells.

Dynamic Responses of Electrorheological Fluid in Steady Pressure Flow (정상압력 유동 하에서 전기유변유체의 동적 응답)

  • Nam, Yun-Joo;Park, Myeong-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2879-2884
    • /
    • 2007
  • Dynamic responses of electrorheological (ER) fluids in steady pressure flow to stepwise electric field excitations are investigated experimentally. The transient periods under various applied electric fields and flow velocities were determined from the pressure behavior of the ER fluid in the flow channel with two parallel-plate electrodes. The pressure response times were exponentially decreased with the increase of the flow velocity, but increased with the increase of the applied electric field strength. In order to investigate the cluster structure formation of the ER particles, it was verified using the flow visualization technique that the transient response of ER fluids in the flow mode is assigned to the densification process in the competition of the electric field-induced particle attractive interaction forces and the hydrodynamic forces, unlike that in the shear mode determined by the aggregation process.

  • PDF

Electro-mechanical properties of Multilayer Ceramic Actuators (적층형 세라믹 액츄에이터의 전기-기계적 거동)

  • Jeong, Soon-Jong;Koh, Jung-Hyuk;Ha, Mu-Su;Lee, Jae-Suk;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.253-256
    • /
    • 2003
  • This study presents the combined effect of electric field application and mechanical compressive stress loading on deformation in a multilayer ceramic actuator, designed with stacking alternatively $0.2(PbMn_{1/3}Nb_{2/3}O_3)-0.8(PbZr_{0.475}Ti_{0.525}O_3)$ ceramics and Ag-Pd electrode. The deformation behaviors were thought to be attributed to relative $180^{\circ}$domain quantities which is determined by pre-loaded stress and electric field. The non-linearity of piezoelectricity and strain are dependent upon the young's modulus resulting from the domain reorientation.

  • PDF

Field Induced Phase Transition in $0.6Pb(Ni_{1/3}Nb_{2/3})O_3-0.31PbTiO_3-0.09PbZrO_3$ Relaxor Ferroelectrics ($0.6Pb(Ni_{1/3}Nb_{2/3})O_3-0.31PbTiO_3-0.09PbZrO_3$ 완화형 강유전체의 전계 유기 상전이 현상)

  • 윤만순;장현명;정회승;최병철
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.6
    • /
    • pp.620-628
    • /
    • 1997
  • The possibility of the existence of a field-induced micro-macrodomain switching was proposed and examined using 9 mol % PbZrO3-doped 0.6Pb(Ni1/3Nb2/3)O3-PbTiO3 (PNN-PT) systems having rhombohedral symmetry at room temperature. the thermally depoled (freshly prepard) specimens prepared from the rhombohedral side of the system exhibited a relaxor behavior for the whole range of temperature examined (for T

  • PDF

In situ Electric-Field-Dependent X-Ray Diffraction Experiments for Ferroelectric Ceramics (강유전 세라믹의 전기장 인가에 따른 in situ X-선 회절 실험)

  • Choi, Jin San;Kim, Tae Heon;Ahn, Chang Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.431-438
    • /
    • 2022
  • In functional materials, in situ experimental techniques as a function of external stimulus (e.g., electric field, magnetic field, light, etc.) or changes in ambient environments (e.g., temperature, humidity, pressure, etc.) are highly essential for analyzing how the physical properties of target materials are activated/evolved by the given stimulation. In particular, in situ electric-field-dependent X-ray diffraction (XRD) measurements have been extensively utilized for understanding the underlying mechanisms of the emerging electromechanical responses to external electric field in various ferroelectric, piezoelectric, and electrostrictive materials. This tutorial article briefly introduces basic principles/key concepts of in situ electric-field-dependent XRD analysis using a lab-scale XRD machine. We anticipate that the in situ XRD method provides a practical tool to systematically identify/monitor a structural modification of various electromechanical materials driven by applying an external electric field.

Low-energy band structure very sensitive to the interlayer distance in Bernal-stacked tetralayer graphene

  • Lee, Kyu Won;Lee, Cheol Eui
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1393-1398
    • /
    • 2018
  • We have investigated Bernal-stacked tetralayer graphene as a function of interlayer distance and perpendicular electric field by using density functional theory calculations. The low-energy band structure was found to be very sensitive to the interlayer distance, undergoing a metal-insulator transition. It can be attributed to the nearest-layer coupling that is more sensitive to the interlayer distance than are the next-nearest-layer couplings. Under a perpendicular electric field above a critical field, six electric-field-induced Dirac cones with mass gaps predicted in tight-binding models were confirmed, however, our density functional theory calculations demonstrate a phase transition to a quantum valley Hall insulator, contrasting to the tight-binding model prediction of an ordinary insulator.