Installation of Induced Current Measurement Systems in Substations and Analysis of GIC Data during Geomagnetic Storms

  • Choi, Kyu-Cheol;Park, Mi-Young;Ryu, Youngsoo;Hong, Youngsu;Yi, Jong-Hyuk;Park, Sung-Won;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.427-434
    • /
    • 2015
  • Coronal Mass Ejections (CME), which originate from active regions of the Sun's surface, e.g., sunspots, result in geomagnetic storms on Earth. The variation of the Earth's geomagnetic field during such storms induces surface currents that could cause breakdowns in electricity power grids. Hence, it is essential to both monitor Geomagnetically Induced Currents (GICs) in real time and analyze previous GIC data. In 2012, in order to monitor the variation of GICs, the Korean Space Weather Center (KSWC) installed an induced current measurement system at SINGAPYEONG Substation, which is equipped with 765 kV extra-high-voltage transformers. Furthermore, in 2014, two induced current measurement systems were installed on the 345 kV high-voltage transformers at the MIGEUM and SINPOCHEON substations. This paper reports the installation process of the induced current measurement systems at these three substations. Furthermore, it presents the results of both an analysis performed using GIC data measured at the SINGAPYEONG Substation during periods of geomagnetic storms from July 2013 through April 2015 and the comparison between the obtained GIC data and magnetic field variation (dH/dt) data measured at the Icheon geomagnetic observatory.

Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment (요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정)

  • Han, Byung-Hee;Choi, Kyung-Moo;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.

A Preliminary Research on Optical In-Situ Monitoring of RF Plasma Induced Ion Current Using Optical Plasma Monitoring System (OPMS)

  • Kim, Hye-Jeong;Lee, Jun-Yong;Chun, Sang-Hyun;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.523-523
    • /
    • 2012
  • As the wafer geometric requirements continuously complicated and minutes in tens of nanometers, the expectation of real-time add-on sensors for in-situ plasma process monitoring is rapidly increasing. Various industry applications, utilizing plasma impedance monitor (PIM) and optical emission spectroscopy (OES), on etch end point detection, etch chemistry investigation, health monitoring, fault detection and classification, and advanced process control are good examples. However, process monitoring in semiconductor manufacturing industry requires non-invasiveness. The hypothesis behind the optical monitoring of plasma induced ion current is for the monitoring of plasma induced charging damage in non-invasive optical way. In plasma dielectric via etching, the bombardment of reactive ions on exposed conductor patterns may induce electrical current. Induced electrical charge can further flow down to device level, and accumulated charges in the consecutive plasma processes during back-end metallization can create plasma induced charging damage to shift the threshold voltage of device. As a preliminary research for the hypothesis, we performed two phases experiment to measure the plasma induced current in etch environmental condition. We fabricated electrical test circuits to convert induced current to flickering frequency of LED output, and the flickering frequency was measured by high speed optical plasma monitoring system (OPMS) in 10 kHz. Current-frequency calibration was done in offline by applying stepwise current increase while LED flickering was measured. Once the performance of the test circuits was evaluated, a metal pad for collecting ion bombardment during plasma etch condition was placed inside etch chamber, and the LED output frequency was measured in real-time. It was successful to acquire high speed optical emission data acquisition in 10 kHz. Offline measurement with the test circuitry was satisfactory, and we are continuously investigating the potential of real-time in-situ plasma induce current measurement via OPMS.

  • PDF

Development of Current Sensor for Pulsed Power and its Characteristics Evaluation (펄스파워 전류 측정용 센서 개발 및 특성 평가)

  • Han, Sang-Bo
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.230-234
    • /
    • 2019
  • This paper shows the development of current sensor for the measurement of hundreds of nanoseconds large current in pulsed power and its characteristics evaluation. The developed current sensor was designed for measuring induced voltage from magnetic flux under the operation of pulsed power. Output characteristics of developed current sensor was good consistent with commercial one, and the realistic current of fast pulsed power was detected easily with the calibration curve using output voltage of developed sensor. Therefore, the developed current sensor is possible to apply the realistic system.

Characteristics and Measurement Method of the Underwater Electromagnetic Signature Emitted from a Naval Ship (함정 발생 수중 전자기장 신호의 특성 및 측정 기법)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.11-19
    • /
    • 2006
  • The underwater electromagnetic signatures of a naval ship are mainly generated from three sources which are the permanent and induced magnetic field in the ship's hull and other ferrous components, the cathodic current electromagnetic field established by the Impressed Current Cathodic Protection(ICCP) system or the Sacrificial Anode and the stray electromagnetic fields generated by onboard equipment. These signatures can be minimized by certain design methods or installation of signature reduction equipment. In this paper, we represented the characteristic of the underwater electromagnetic signature and the signature reduction techniques for a naval ship. Also, we measured the electromagnetic field changes emitted from the real ship using the Electric and Magnetic field Measurement System(EMMS). We found that the underwater electromagnetic signature for a naval ship can be used as input or trigger signal in a surveillance system and an influence mine.

Study about the Application of Rogowski Coil for measuring Partial Discharge Current (부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구)

  • Lee, Kang-Won;Yoon, Sung-Cheol;Kim, Myung-Yong;Baik, Kwang-Sun;Na, Dong-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

Tensile Stress Measurement of Tendon by Means of Non-contact Yoke Method (Yoke를 사용한 비접촉 방법에 의한 텐던 인장응력 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.19-23
    • /
    • 2016
  • In this study, we have constructed a measuring system to investigate tensile stress measurement of tendons, which is employed in bridges, by means of the non-destructive and non-contact method. The measuring system consists of tensile stress applying apparatus up to 2 GPa, and power supply for ac and dc current to tendon directly to magnetize tendon in circular direction and to coil wound on yoke to magnetize tendon in axial direction. We have used two kinds of tendon, which were produced by different companies, using the measuring system constructed in this work. Two kinds of experiments are carried out in this work; $1^{st}$ experiment : ac current was applied to the tendon and dc current was applied to coil wound on the yoke, and voltage induced from search coil wound on yoke (SCY) was measured and $2^{nd}$ experiment : dc current was applied to the tendon and ac current was applied to coil wound on the yoke, and voltage induced from search coil on tendon (SCT) was measured. In case of $1^{st}$ experiment, voltage induced from SCY was changed below 200MPa tensile stress but the voltage was not increased above 200 MPa. In case of $2^{nd}$ experiment, voltage induced from SCT was decreased up to 1.5 GPa linearly. We expect that $2^{nd}$ experiment could be applied to the non-destructive testing of tensile stress measurement of tendon.

Analysis of Return Current Effect for AF Non-insulated Track Circuit in ITX Vehicle Operation (ITX 차량 운행에 의한 AF 무절연 궤도회로의 귀선전류 영향 분석)

  • Beak, Jong-Hyen;Kim, Yong-Kyu;Yoon, Yong-Ki;Jang, Dong-Wook;Shin, Dong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.584-590
    • /
    • 2013
  • Depending on the operating characteristics, track circuit is installed for the purpose of control directly or indirectly of the signal device, point switch machine and other security device. These are mainly used for train detection, transmission of information, broken train detection and transmission of return current. Especially, the return current is related to signal system, power system and catenary line, and track circuit systems. It is one of the most important component shall be dealt for the safety of track side staff and for the protection of railway-related electrical system according to electrification. Therefore, an accurate analysis of the return current is needed to prevent the return current unbalance and the system induced disorder and failure due to an over current condition. Also, if the malfunction occurred by the return current harmonics, it can cause problems including train operation interruption. In this paper, we presented measurement and analysis method at return current and it's harmonics by train operation. By the test criteria, we evaluated for safety. Hereafter, it is expected to contribute to the field associated with it.

Measurement of Stator Core Loss of an Induction Motor at Each Manufacturing Process

  • Jeong, Kwangyoung;Ren, Ziyan;Yoon, Heesung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1309-1314
    • /
    • 2014
  • The measurement of stator core loss for an induction motor at each manufacturing process is carried out in this paper. Iron loss in the stator core of induction motor changes after each manufacturing process due to the mechanical stress, which can cause the deterioration of the magnetic performances. This paper proposes a new iron loss measuring system of the stator core in an induction motor, which can be applied to the case when the distribution of magnetic flux density is not uniform along the magnetic flux path. In the system, the iron loss is calculated based on the induced voltage of the B-search coil and exciting current.

Measurement and Comparison of Iron Loss in Bonded- and Embossed-Type Segmented Stator Cores for IPMSM

  • Jeong, Kwangyoung;Zhang, Dianhai;Kwon, Jaehoon;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2013-2018
    • /
    • 2014
  • According to the manufacturing process of the laminated stator core for an inserted permanent magnet synchronous motor (IPMSM), the iron loss may be different. It is because the mechanical stress imposed to electrical steel sheet is strongly dependent on the manufacturing process. This paper proposes a new iron loss measurement algorithm which utilizes the induced voltage of a search coil and exciting current. The method is effective even when the distribution of magnetic flux density is not uniform along the magnetic flux path as well as uniform. The developed iron loss measurement system is applied to bonded- and embossed-type segmented stator cores of an IPMSM, and the iron losses are quantitatively compared.