• 제목/요약/키워드: induced current

검색결과 2,712건 처리시간 0.032초

Ellipso-Microscopic Observation of Titanium Surface under UV-Light Irradiation

  • Fushimi, K.;Kurauchi, K.;Nakanishi, T.;Hasegawa, Y.;Ueda, M.;Ohtsuka, T.
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.265-270
    • /
    • 2016
  • The ellipso-microscopic observation of a titanium surface undergoing anodization in $0.05mol\;dm^{-3}$ of $H_2SO_4$ was conducted. During irradiation by ultra-violet (UV) light with a wavelength of 325 nm, the titanium surface allowed for the flow of a photo-induced current and showed up as a bright, patch-like image on an ellipso-microscopic view. The brightness and patch-pattern in the image changed with flowing photo-induced current. The changes in the brightness and the image corresponded to the formation and/or degradation of titanium oxide due to the photo-electrochemical reaction of the oxide. An in situ monitoring using the ellipso-microscope revealed that the film change was dependent on the irradiation light power, by UV-light increases the anodic current and results in the initiation of pitting at lower potentials as compared with the non-irradiated condition.

DNV 2002에 의한 해저관로의 자유경간해석 (Free Spanning of Offshore Pipelines by DNV 2002)

  • 최한석;주주경
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.29-33
    • /
    • 2002
  • A procedure of free span and fatigue analysis of offshore pipelines was made per DNV-RP-F105, 2002. The new method includes the axial force and deflection load in pipelines. The screening criteria were used to calculate the allowable span lengths. The screening criteria allow small amplitudes of vortex-induced vibration due to wave and current loading. However, the induced pipe stress is very small and usually below the limit stress of a typical S-N curve. A simplified method was established to calculate the fatigue damage due to long-term current distribution. The long-term current statistics was assumed with a 3-parameter Weibull distribution. The fatigue damage was estimated for the span lengths obtained from the screening criteria for various conditions. Sample calculations show the effect of axial force for various boundary conditions.

  • PDF

Analysis of the Magnetic Effect on the Tube Infrastructure for a Super Speed Tube Train

  • Lee, Hyung-Woo;Cho, Su-Yeon;Cho, Woo-Yeon;Lee, Ju;Kwon, Hyeok-Bin
    • International Journal of Railway
    • /
    • 제2권4호
    • /
    • pp.170-174
    • /
    • 2009
  • Super speed tube train is introduced to increase the speed of ground transportation. The super speed tube train levitates magnetically and runs in a partial vacuum tube, which can reduce the air resistance significantly. However, the strong magnetic force enough to propel the massive train can affect to the tube infrastructure. In this paper, authors have analyzed the leakage flux patterns and induced eddy current on the tube by using 3-dimensional Finite Element Method. These effects are investigated, especially by varying the materials and diameters of the tube. From the simulation results, the aluminum tube with the diameter of 3[m] is needed to be concerned because the induced eddy current produces joule heat, raises the inside temperature of the tube, and might be able to lead to electro-chemical corrosion on the tube, consequently reduce the durability.

  • PDF

공간고조파법을 이용한 반경방향 영구자석을 갖는 자기커플링의 와전류 손실 해석 (Eddy Current Loss Analysis in Radial Flux Type Synchronous Permanent Magnet Coupling using Space Harmonic Methods)

  • 민경철;강한빛;박민규;조한욱;최장영
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1377-1383
    • /
    • 2014
  • This paper deals with eddy current loss of magnetic coupling with radial permanent magnet (PM) using analytical method such as a space harmonic method. Superposition of two kinds analysis model is used to analyze eddy current loss induced in inner PM and outer PM of magnetic coupling. When the eddy current is induced, the environmental temperature increases, and the permanent magnet(PM) characteristics are degraded because the performance of PM is greatly influenced by temperature rise. Hence, the calculation of eddy current loss becomes an important factor in the magnetic coupling. In order to analyze eddy current loss, first, on the basis of the magnetic vector potential and two-dimensional(2-D) polar-coordinate system, the magnetic field solutions of the radial magnetized PM are obtained. And we obtain the analytical solutions for the eddy current density produced by permanent magnet. Lastly, analytical solutions for eddy current loss are derived by using equivalent, electrical resistance calculated from magnet volume and analytical solution for eddy current density. This analytical results are validated by comparing with the 2-D finite element analysis (FEA).

흰쥐 교감신경세포에서 Norepinephrine 에 의한 칼슘전류 억제에 미치는 Protein Kinase C 의 역할 (Role of Protein Kinase C on Norepinephrine Induced Inhibition of Calcium Current in Rat Sympathetic Neurons)

  • 구용숙
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.29-38
    • /
    • 2000
  • 지금까지 각종 신경전달물질의 칼슘통로 억제 효과는 일반적으로 protein kinase 의 관여없이 G-protein mediated, membrane-delimited mechanism$^{1)}$ 으로 설명되어왔다. 그러나 최근들어 protein kinase C (PKC)의 활성화가 몇몇 신경전달물질에 의한 칼슘통로 억제효과를 야기하는 중요한 세포내 기전으로 보고되고 있다 그러므로 본 연구에서는 흰쥐 교감신경뉴론을 대상으로 하여 whole cell patch clamp technique을 사용하여 칼슘전류를 기록하고, 세포밖에 norepinephrine (NE)과 함께 PKC agonist 인 phorbol-12, 13-dibutyrate (PDBu)을 투여하면서 PDBu 전 처치로 인하여 NE 에 의한 칼슘전류 억제에 어떤 변화가 초래되는 지를 분석함으로써, 신경전달물질의 칼슘전류 억제효과시 PKC의 역할을 밝히고자 하였다. PDBu (500 nM) 처치는 칼슘전류의 크기를 증가시켰으며 이는 막전압 의존성을 보여 -10 mV ~ +10 mV 의 저분극 자극시 가장 크게 전류크기가 증가하였다. 또한 PDBu 처치는 tail current 의 deactivation을 느리게 하였다. PDBu 는 NE 에 의하여 활성화되는 pertussis toxin 예민성 G protein pathway를 통한 칼슘전류 억제를 감소시켰다. 비특이적인 protein kinase 길항제인 staurosporine (1 $\mu$M) 을 전처치 하고 PDBu를 투여하면 PDBu의 칼슘전류 크기 증가 효과가 소실되었으며 또한 NE에 의한 칼슘전류 억제를 해제하는 PDBu 의 조절효과도 소실되었다. 이상의 결과로부터 Protein Kinase C 가 활성되면 G protein을 경유하여 나타나는 칼슘전류 억제 효과가 소실된다고 결론지을 수 있다. Protein Kinase C 에 의하여 인산화되는 부위가 G-protein 인지 혹은 칼슘통로인 지에 관한 해답을 얻기 위하여는 추후 연구가 진행되어야 한다.

  • PDF

우리나라 유배우부인의 인공임신중절에 관한 연구 (A Study on the Induced Abortion Behavior of Currently Married Women in Korea)

  • 오영희
    • 한국인구학
    • /
    • 제9권2호
    • /
    • pp.42-52
    • /
    • 1986
  • An attempt had been made to obtain current information on induced abortion among currently married women aged 15 to 44. The source of data was 1985 National Fertility and Family Planning Survey conducted by Korea Institute for Population and Health in may 1985. 1. At the time of the survey, 53 percent of currently married women aged 15 to 44 had experienced induced abortion: 25.5 percent of the respondents who had experienced induced abortion only one time and another 27.6 percent more than two times. 2. The proportion of women who had experienced induced abortion seemed to increase according to the advance in age. It seemed that there was no significant difference in the experience rate of induced abortion by academic career, and there was inverse relationship between the experience rate of induced abortion and the age at first marriage. The experience rate if induced abortion by the number of living children was highest among those who had three children as 65.6 percent. 3. To analyze the effect of induced abortion on fertility, this study employed multiple regression analysis as a statistical technique. Instead of index representing fertility level the number of living children served as dependent variable. Independent variables used in analysis included age, age at first marriage, education level, ideal number of children, religion, frequency of induced abortion, total number of pregnancies and participation in labor force. Standardized partial regression coefficient of induced abortion was no less than -0.61. So, it can be concluded that induced abortion offered the great contribution on the birth control. A consistant health education and efficient management of family planning program would be essential for effectiveness of contraceptive practice.

  • PDF

와류기인진동을 이용한 신재생에너지 발전에서 유체력 추정연구 (Estimation of Fluid Force for Renewable Energy Generation Using Vortex-induced Vibrations)

  • 박홍래
    • 신재생에너지
    • /
    • 제19권2호
    • /
    • pp.23-30
    • /
    • 2023
  • Vortex-induced vibrations are a type of flow-induced vibrations caused by alternating lift forces. With increasing demand for renewable energy, the application of vortex-induced vibrations to renewable energy has been widely studied. Vortex-induced vibrations for aquatic clean energy (VIVACE) converter is a renewable energy device that generates electricity from rivers or oceans using vortex-induced vibrations. To increase the design life and power harnessing capacity of the VIVACE converter, the estimation of fluid forces due to vortex-induced vibrations is essential. Herein, vortex-induced vibrations were experimentally tested, and their amplitude and frequency response were measured. The amplitude results showed four different branches: initial branch, upper branch, lower branch, and desynchronization range. According to the fluid force coefficient results, the maximum lift coefficient occurred at the upper branch. Additionally, a mathematical model is proposed to estimate fluid forces due to vortex-induced vibrations without using measurement devices. This mathematical model enables the estimation of fluid force coefficients and phase lag using amplitude and frequency response of vortex-induced vibrations.

Mechanism of Glutamate-induced $[Ca^{2+}]i$ Increase in Substantia Gelatinosa Neurons of Juvenile Rats

  • Jung, Sung-Jun;Choi, Jeong-Sook;Kwak, Ji-Yeon;Kim, Jun;Kim, Jong-Whan;Kim, Sang-Jeong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권2호
    • /
    • pp.53-57
    • /
    • 2003
  • The glutamate receptors (GluRs) are key receptors for modulatory synaptic events in the central nervous system. It has been reported that glutamate increases the intracellular $Ca^{2+}$ concentration ($[Ca^{2+}]_i$) and induces cytotoxicity. In the present study, we investigated whether the glutamate-induced $[Ca^{2+}]_i$ increase was associated with the activation of ionotropic (iGluR) and metabotropic GluRs (mGluR) in substantia gelatinosa neurons, using spinal cord slice of juvenile rats (10${\sim}21 day). $[Ca^{2+}]_i$ was measured using conventional imaging techniques, which was combined with whole-cell patch clamp recording by incorporating fura-2 in the patch pipette. At physiological concentration of extracellular $Ca^{2+}$, the inward current and $[Ca^{2+}]_i$ increase were induced by membrane depolarization and application of glutamate. Dose-response relationship with glutamate was observed in both $Ca^{2+}$ signal and inward current. The glutamate-induced $[Ca^{2+}]_i$ increase at holding potential of -70 mV was blocked by CNQX, an AMPA receptor blocker, but not by AP-5, a NMDA receptor blocker. The glutamate-induced $[Ca^{2+}]_i$ increase in $Ca^{2+}$ free condition was not affected by iGluR blockers. A selective mGluR (group I) agonist, RS-3,5-dihydroxyphenylglycine (DHPG), induced $[Ca^{2+}]_i$ increase at holding potential of -70 mV in SG neurons. These findings suggest that the glutamate-induced $[Ca^{2+}]_i$ increase is associated with AMPA-sensitive iGluR and group I mGluR in SG neurons of rats.

와이어 소잉 데미지 층이 단결정 실리콘 태양전지 셀 특성에 미치는 영향 (Relation Between Wire Sawing-damage and Characteristics of Single Crystalline Silicon Solar-cells)

  • 김일환;박준성;박재근
    • Current Photovoltaic Research
    • /
    • 제6권1호
    • /
    • pp.27-30
    • /
    • 2018
  • The dependency of the electrical characteristics of silicon solar-cells on the depth of damaged layer induced by wire-sawing process was investigated. To compare cell efficiency with residual sawing damage, silicon solar-cells were fabricated by using as-sawn wafers having different depth of saw damage without any damaged etching process. The damaged layer induced by wire-sawing process in silicon bulk intensely influenced the value of fill factor on solar cells, degrading fill factor to 57.20%. In addition, the photovoltaic characteristics of solar cells applying texturing process shows that although the initial depth of saw-damage induced by wire-sawing process was different, the value of short-circuit current, fill-factor, and power-conversion-efficiency have an almost same, showing ~17.4% of cell efficiency. It indicated that the degradation of solar-cell efficiency induced by wire-sawing process could be prevented by eliminating all damaged layer through sufficient pyramid-surface texturing process.