• 제목/요약/키워드: indoor temperature and humidity

검색결과 394건 처리시간 0.027초

인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석 (An Investigation and Analysis into the Architectural Conditions and Indoor Air Quality of Senior Citizens Public Welfare Institution in Incheon)

  • 강승아;신성식;김용식
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.59-64
    • /
    • 2009
  • The senior citizens population and welfare institution for them is increased. The senior citizens in welfare institution spend a long time in indoor and their health is greatly affected by the indoor environment. Therefore, the indoor environment of senior citizens welfare institution is very important. This study presents some primary data based on the survey of architectural conditions and the measurements of indoor air quality for senior citizens welfare institution. According to characteristic of region, six of Incheon Area's senior citizens public welfare institution are selected. An investigation and analysis into architectural conditions and indoor air quality including temperature, humidity, CO, $CO_2$, PM10, HCHO, TVOC are conducted. The temperature, humidity and $CO_2$ concentration is some high. The HCHO concentration is very high. The indoor flooring and furniture materials highly impacts on the concentration of HCHO and TVOC.

철도차량 객실 온습도 USN 모니터링 기술 (Temperature and Humidity Monitoring Using Ubiquitous Senor Network in Railway Cabin)

  • 권순박;조영민;박덕신;박은영;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.948-951
    • /
    • 2008
  • Ubiquitous sensor network (USN) based on ZigBee communication protocol has been used in various application fields, such as home-network, intelligent building and machine, logistics, environmental monitoring, military field, security field and etc. The ZigBee is targeted at radio-frequency application that require a low data rate, long battery life and secure network. Especially, the USN system can be applied efficiently to building-indoor where the complex geometry is adopted. In this study, all 90 points of railway cabin indoor were monitored for temperature and humidity using USN technology. All sensors were pre/post-calibrated and the temperature/humidity change were analyzed in a railway cabin in real-time. The results would be useful to develop the cabin heating, ventilating and air conditing (HVAC) system to meet all passengers' thermal comfort regardless of their seat position.

  • PDF

Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가 (A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room)

  • 송민정;신훈
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.

Effects of Heat Wave on Body Temperature and Blood Pressure in the Poor and Elderly

  • Kim, Young-Min;Kim, So-Yeon;Cheong, Hae-Kwan;Ahn, Byun-Gok;Choi, Kyu-Sik
    • Environmental Analysis Health and Toxicology
    • /
    • 제27권
    • /
    • pp.13.1-13.10
    • /
    • 2012
  • Objectives: We aimed to investigate the acute effects of heat stress on body temperature and blood pressure of elderly individuals living in poor housing conditions. Methods: Repeated measurements of the indoor temperature, relative humidity, body temperature, and blood pressure were conducted for 20 elderly individuals living in low-cost dosshouses in Seoul during hot summer days in 2010. Changes in the body temperature, systolic blood pressure (SBP) and diastolic blood pressure (DBP) according to variations in the indoor and outdoor temperature and humidity were analyzed using a repeated-measures ANOVA controlling for age, sex, alcohol, and smoking. Results: Average indoor and outdoor temperatures were $31.47^{\circ}C$ (standard deviation [SD], $0.97^{\circ}C$) and $28.15^{\circ}C$ (SD, $2.03^{\circ}C$), respectively. Body temperature increased by $0.21^{\circ}C$ (95% confidence interval [CI], 0.16 to $0.26^{\circ}C$) and $0.07^{\circ}C$ (95% CI, 0.04 to $0.10^{\circ}C$) with an increase in the indoor and outdoor temperature of $1^{\circ}C$. DBP decreased by 2.05 mmHg (95% CI, 0.05 to 4.05 mmHg), showing a statistical significance, as the indoor temperature increased by $1^{\circ}C$, while it increased by 0.20 mmHg (95% CI, -0.83 to 1.22 mmHg) as outdoor temperature increased by $1^{\circ}C$. SBP decreased by 1.75 mmHg (95% CI, -1.11 to 4.61 mmHg) and 0.35 mmHg (95% CI, -1.04 to 1.73 mmHg), as the indoor and outdoor temperature increased by $1^{\circ}C$, respectively. The effects of relative humidity on SBP and DBP were not statistically significant for both indoor and outdoor. Conclusions: The poor and elderly are directly exposed to heat waves, while their vital signs respond sensitively to increase in temperature. Careful adaptation strategies to climate change considering socioeconomic status are therefore necessary.

실내수영장의 열, 기류 및 습도환경에 관한 연구 (A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool)

  • 강석윤;이태구;문종선;이재헌
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.

온실내 공기 유동팬이 열환경에 미치는 영향 (Effects of Air Circulation Fan on Thermal Environments in Greenhouse)

  • 유인호;김문기;윤남규
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.250-254
    • /
    • 1998
  • This paper shows how the environmental parameters(temperature, humidity) in the greenhouse are influenced by air movement produced by air circulation fans. When the fans were used, they could make indoor temperature and humidity homogenious, but there was no significant difference in the location and number of fans. When the fans were not used during the night time, there was no significant difference in the temperature and humidity, but the standard deviation was reduced by using the fans.

  • PDF

문화재 보존시설에서의 습도지시카드 적용성 연구 (The Application of Humidity Indicators for Environmental Measurement Apparatus of Preservation Facility)

  • 임보아;신은정;도민환
    • 보존과학연구
    • /
    • 통권30호
    • /
    • pp.47-61
    • /
    • 2009
  • Cultural heritages are affected by various environmental factors. Main factors are temperature, humidity, light and indoor air pollutants such as ozone, nitrogen oxides. Especially humidity condition is very important. Low humidity condition can cause contraction and high humidity condition can lead to growth of microorganism. This study is conducted to appraise an applicability of the Humidity Indicator which is one of the simple method for humidity control. The Humidity Indicator shows the humidity conditions through color change. Therefore, photometer was used to correctly measure the color change of Humidity Indicator. As a result of lab test, Humidity Indicators was stabilized after one hour from en exposure in a certain humidity condition and the indicators indicated clear correlations between color changes of Humidity Indicators and humidity conditions. Some Humidity Indicators which had been selected through the lab tests were applied to preservation facilities of cultural heritages and the indicators indicated closed correlations with humidity conditions in indoor of facilities.

  • PDF

A Seasonal Indoor Thermal Conditions of a Newly-launched Training Ship

  • Hwang, Kwang-Il;Shin, Dong-Keol;Lee, Jin-Uk;Lee, Sang-Il
    • 한국항해항만학회지
    • /
    • 제33권4호
    • /
    • pp.289-294
    • /
    • 2009
  • The living performances of crews and passengers in cabins have been less received attention, while Korea is a top leading country in ship building industry. To develop a high value added ships like 5-star cruisers, researches on the comfort and productivity in cabins should be carried out with urgent. The purpose of this study is to measure and analyze of the ship's indoor thermal conditions in spring, summer and winter, and also to compare the seasonal differences, of which conditions are supplied from and controlled by marine HVAC The temperature, humidity and air supply volume of 5 different needs of cabins on a training ship were measured through a year, which was launched at Dec. 2005 and totally 246 crews can go on board for education. The following results were obtained: (1)In the spring, the temperature in cabins was measured as $20{\sim}25^{\circ}C$ and humidity was below 30%. (2)In the summer, the temperatures was controlled at $21{\sim}27^{\circ}C$ in almost cabins and humidity was between $40{\sim}60%$ which is known as comfort conditions. (3)In the winter, temperature and humidity was maintained between $19{\sim}26^{\circ}C$, and humidity was between $10{\sim}50%$. (4)It is clear that the humidity conditions in cabins are not properly controlled at all through a year to satisfy the Comfort Standards provided by ASHRAE and/or ISO, In conclusion, humidification and dehumidification of cabins must be treated with importance for more comfort living and working environments for crews and passengers.

신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가 (A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier)

  • 황광일;도근영;조효제;우상우;신동걸;임성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구 (An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province)

  • 이태강;최은석;김항;김형렬;기노갑;김선우
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.