• 제목/요약/키워드: indoor temperature and humidity

검색결과 396건 처리시간 0.022초

농촌지역 독거노인주택의 겨울철 실내환경 실태 (The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter)

  • 최윤정;김윤희;김란희
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.452-457
    • /
    • 2008
  • The purposes of this study were to determine the actual state of indoor environment and to analyze the relationship between the living factors and indoor physical elements in solitary elderly houses at rural district during winter. The field surveys were consisted of measurements of physical elements, observations of living factors, and interviews of resident's responses. The field surveys were fulfilled in 4 houses from February to March 2008. Measuring elements were air temperature, relative humidity, floor temperature, seated place temperature, $CO_2$, CO, and illumination. The results showed that the average of indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was $30.6{\sim}55.4%$, floor temperature was $13.9{\sim}24.0^{\circ}C$, seated place temperature was $27.6{\sim}51.1^{\circ}C$, $CO_2$ was $1434.6{\sim}3305.5ppm$, CO was $2.8{\sim}8.4ppm$, illumination was $31.0{\sim}96.7lux$. The residents' clothing values were $1.10{\sim}1.78clo$. Most of the residents' subjective responses were in discord with the physical elements. It was evaluated to be uncomfortable state, and the main reason was revealed lack of heating and ventilation.

  • PDF

아파트 실내정원의 겨울철 실내온열환경 조절효과 (Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter)

  • 김정민;최윤정
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF

하절기, 석재 모형돔의 외피 유형별 실내환경 요소에 관한 연구 (A study on indoor environmental elements of the granite model dome in different envelope materials during summer season)

  • 공성훈
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.898-902
    • /
    • 1999
  • During summer season, the weather condition of Korea is hot and humid. So humidity elements are very important relating to building envelope condition. The purpose of this investigation is to measure and analyze characteristics of summer's environmental elements such as relative humidity, dry bulb temperature and air velocity in the clay/cement envelope materials using a granite dome model. According to the variation of exterior humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

공동주택의 실내 열환경에 대한 평가방법개발 (Development of Methods for Evaluation of Indoor Thermal Environment of Apartment Housing)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제35권6호
    • /
    • pp.101-110
    • /
    • 1997
  • The intent of this study is to propose a method for appraisal of the indoor thermal environment of apartment housing by measuring physical factors and residents' response to questionnaire survey. The experiments were performed on eight houses each in summer (August 18 through 31,1995) and winer (february 16 through 20,1996). It included measurements of indoor air temperature, globe temperature, relative humidity, and CO2 concentration. The questionnaire surveys were performed each in summer (July 16 through 20, 1996) and winer (February 13 through 16, 1996). And 248 cases in summer and 297 cases in winter were used in analysis. These questionnaire surveys asked residents' response about thermal sensation, humidity sensation, sense of air freshness regarding the indoor thermal environment. data acquired through the experiments and questionnaire surveys were then transferred to scales that allowed relative comparison, and measured to an appraisal standard chart. Appraisal tools included appraisal charts and radar charts. Indoor thermal environment was judged to be positive according to experiments, but residents appraised the thermal environment to be average. This difference between the two can be found in the strict standards by which residents judge the thermal environment of their apartments.

  • PDF

실내 수공간으로 인한 온열환경 변화와 휴식의자 배치 방안 (A Study on the Place of Break Chair Thermal Environment Change with the Introduction of the Indoor Water Space)

  • 강유진;송준이;정옥영;김수민
    • 한국가구학회지
    • /
    • 제24권3호
    • /
    • pp.239-246
    • /
    • 2013
  • Recently the building is introducing the indoor water space. Thermal environment change with the introduction. Consequently, this study shows how water space in the public facility affects the indoor environment. We had put our experiment to measure the humidity and temperature differences in different distances of water space. The result of this study is as follows. First, We found that even though there's a water space, it makes no big change in temperature by different distance. The temperature was only maintained by a cooler. Second, As there's a water space, the humidity was affected by within 1.5 m of it. Through our experimental result, we have started our study to make a water space effective.

  • PDF

외기 온습도 조건에 따른 폐열회수 환기장치의 열전달 특성 및 불확실성에 관한 연구 (A Study on Heat Transfer Characteristics and Uncertainty of Heat Recovery Ventilator for Various Outdoor Temperature/Humidity Conditions)

  • 한화택;추연복
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.608-613
    • /
    • 2008
  • The purpose of the present paper is to investigate the effect of outdoor weather conditions on the performance of a heat recovery ventilator. Experiments have been performed by varying outdoor temperature/humidity conditions with the indoor conditions fixed at the standard conditions by KARSE. Results indicate humidity efficiency shows larger uncertainties than temperature efficiency in general. With the heat generation by an internal fan removed, the modified temperature efficiency remains almost constant regardless of the indoor-outdoor temperature difference. The enthalpy efficiency can have very large or negative values in case the outdoor conditions are in the vicinity of the indoor enthalpy line. The direction of heat flow, in such a case, can be opposite to that of moisture flow between two air streams. Discussions are included about various interesting features of the psychrometric processes taking place in a heat recovery ventilator.

쾌적한 실내 환경을 조성하기 위한 아두이노의 온도와 습도를 이용한 퍼지 기반의 팬 제어 연구 (Fuzzy-based Fan Control using Arduino's Temperature and Humidity for Comfortable Indoor Environment)

  • 김재홍;김재우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.389-392
    • /
    • 2018
  • 본 논문에서는 덥고 습한 실내에서 온도,습도에 의해 움직이는 팬을 적절하게 조절하여 쾌적 환경을 조성하고자 한다. 이를 위해 실내 온도와 습도를 이용한 퍼지 기반의 팬 제어를 제안하고, 이를 아두이노를 이용하여 실내 온, 습도 등의 환경 데이터 수집하고, 블루투스 통신으로 전달하고, 퍼지 로직에 따라 팬의 동작 시간을 조절한다. 먼저 이를 위해 아두이노 하드웨어에 온도 습도 센서를 연결하고, 컴퓨터에 있는 아두이노 프로그램을 이용해서 소스코드를 작성하고 아두이노에 코딩한다. 그뒤 아두이노로부터 온도와 습도 등의 환경 데이터 수집하고 나서 얻은 환경 데이터를 아두이노 제어 모듈에 블루투스 통신으로 전달한다. 전달 받은 환경데이터를 퍼지 로직을 이용하여 온도 습도 등 환경 데이터에 따라 팬이 동작하는 시간을 조절한다. 이 과정이 끝나면 팬이 온도,습도에 따라 동작하여 환경을 쾌적하게 조성 한다. 이 연구를 통해 아두이노는 더욱 간단하고 일반인들도 쉽게 사용이 가능하고, 아두이노 하드웨어, 데이터 수집, 퍼지 로직, 제어 등을 이용하여 실생활에 활용할 수 있다.

  • PDF

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

박물관 실내공기질 변동에 관한 연구 (Variation of Indoor Air Quality in Museum)

  • 이정주;김신도;부문자
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구 (A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season)

  • 민병철;전지현;국찬
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.