Concentration and identification of airborne bacteria in the regulated public facilities were examined with the six-stage cascade impactor. Geometric mean total and respirable concentrations of airborne bacteria were $404cfu/m^3$ and $194cfu/m^3$ in hospital, $931cfu/m^3$ and $358cfu/m^3$ in kindergarten, $294cfu/m^3$ and $134cfu/m^3$ in day-care center, and $586cfu/m^3$ and $254cfu/m^3$ in postpartum nurse center, respectively. As a result, culturable total and respirable concentrations of airborne bacteria were significantly highest in kindergarten and lowest in day-care center (p<0.05). The ratio of respirable to total concentration of airborne bacteria in the investigated public facilities was ranged from 30% to 40% but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.58 and 0.66 in hospital, 0.71 and 0.83 in kindergarten, 0.28 and 0.41 in day-care center, and 0.63 and 0.78 in postpartum nurse center, respectively. Day-care center showed the lowest I/O ratio of culturable total and respirable concentration of airborne bacteria (p<0.05) but a significant difference was not found among other facilities. Indoor concentration of airborne bacteria did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ and surrounding condition (p<0.05). Staphylococcus spp., Micrococcus spp., Corynebacterium spp., and Bacillus spp. were dominant genera and amounted to over 95% of total airborne bacteria identified in the investigated public facilities. Size distributions of four dominant genera did not observed inconsistently regardless of type of public facility.
논산 개태사지석불입상(보물 제219호)은 담회색을 띠고 부분적으로 장석 반정을 함유하고 있는 중립 내지 조립질의 화강섬록암으로 구성되어 있다. 구성암석의 전암대자율은 평균 12.06(${\times}10^{-3}$ SI unit)으로 개태사지 배후의 천호산 ($0.19{\times}10^{-3}$ SI unit) 노두와는 많은 차이를 보이고 있어 석재의 외부 유입 가능성이 제기된다. 이 석불입상은 우협시불의 박리(35.2%), 본존불의 시멘트 보수물질(21.1%) 및 먼지(25.0%)가 주요한 손상현상으로 밝혀졌다. 초음파 속도는 본존불 2850.2m/s, 좌협시불 2648.4m/s, 우협시불 2644.5m/s로 측정되었다. 이를 통해 산정한 일축압축강도는 우협시불이, 부위별로는 대좌에서 상대적으로 낮은 강도를 나타내어 손상도 평가 결과와 일치하였다. 석불입상이 봉안된 보호각 내부의 연평균 기온은 $13.7^{\circ}C$, 상대습도는 79.0%로, 계절에 따른 보호각 내부의 환경 변화는 근본적으로 외부의 변화를 따르나 미기후 변동이 심하지 않아 비교적 안정된 실내 환경이 유지되고 있다. 석불입상의 대좌 표면에서는 봄과 여름철에 결로가 발생하는 것으로 확인되었으며, 겨울철에는 동결파괴가 우려된다. 이는 훼손도 평가와 초음파 탐사 결과에서 나타난 대좌의 풍화 및 강도 저하의 근본적인 요인일 가능성이 매우 크다. 따라서 봄과 여름철에 집중 강우 시 실내의 제습과 한겨울에 기온 강하를 저감시킬 수 있는 조치가 필요하다.
Kim, Byeong-Chan;Kim, Hye-Jin;Kim, Ji-Eun;Park, Eun-Ju;Noh, Ji-Sun;Kang, Hyun-Jung;Shin, Seung-Ho;Jo, Wan-Kuen
청정기술
/
제19권2호
/
pp.105-112
/
2013
폴리아닐린 기반 이산화티타늄 복합체(폴리아닐린-이산화티타늄 복합체)를 다른 소성온도 조건에서 제조하여 일반 공기질 수준의 트리클로로에틸렌과 테트라클로로에틸렌에 대한 제어 적용성 연구를 수행하였다. 모든 조사대상 오염물질에 대하여 폴리아닐린-이산화티타늄 복합체의 제어효율은 제조 시 적용된 소성온도 변화에도 아무런 경향을 나타내지 않았다. 대신에, 소성온도를 $350^{\circ}C$에서 $450^{\circ}C$로 증가시켰을 때 3시간의 광촉매 공정 동안에 폴리아닐린-이산화티타늄 복합체의 제어효율은 트리클로로에틸렌과 테트라클로로에틸렌에 대하여 61%에서 72%로, 21%에서 39%로 각각 증가하였다. 그러나, 소성온도를 $450^{\circ}C$에서 $550^{\circ}C$와 $650^{\circ}C$로 더 증가시켰을 경우에는 폴리아닐린-이산화티타늄 복합체에 의한 트리클로로에틸렌과 테트라클로로에틸렌의 제어효율이 점진적으로 감소하였다. 이러한 결과는 폴리아닐린-이산화티타늄 복합체 내 아나타제 결정상의 생성량과 입자의 비표면적 변화 때문으로 판단되었고, 이러한 특성 변화는 X-선 회절과 주사전자현미경 분석결과를 통하여 확인하였다. 가장 낮은 주입농도(0.1 ppm) 조건에서 트리클로로에틸렌과 테트라클로로에틸렌의 평균 제어효율은 각각 72%와 39%이었고, 반면에 가장 높은 주입농도(1.0 ppm) 조건에서는 트리클로로에틸렌과 테트라클로로에틸렌의 평균 제어효율은 각각 52%와 18%로 나타났다. 공급 유량을 0.1 L $min^{-1}$에서 1.0 L $min^{-1}$로 증가시켰을 때 트리클로로에틸렌과 테트라클로로에틸렌의 평균 제어효율이 각각 약 100%에서 47% 그리고 약 100%에서 18%로 감소하였다. 또한, 상대 습도를 20%에서 95%로 증가시켰을 때 트리클로로에틸렌과 테트라클로로에틸렌의 평균 제어효율이 각각 약 100%에서 23% 그리고 약 100%에서 8%로 대폭 감소하였다. 본 연구결과를 종합해볼 때, 작동조건을 최적화할 경우 폴리아닐린-이산화티타늄 복합체가 일반 공기질 농도 수준의 염소계 화합물질 제어를 위해서 효율적으로 이용될 수 있는 것으로 나타났다.
본 연구는 오이(Cucumis sativus L.)의 광합성, 생육 및 수분이용효율을 분석하고 생장해석을 통해 생육 온도와 관수 주기가 식물에 미치는 영향에 대해 알아보고자 환경 제어가 가능한 실내 재배상에서 광도(70W·m-2)와 상대습도(65%)를 동일하게 설정하여 수행하였다. 처리는 주/야간 온도(℃)를 15/10℃, 25/20℃및 35/25℃로 3처리하였고, 각 온도별 관수 주기를 1일 1회 100mL(S), 2일 1회 200mL(L)로 달리 공급하는 처리를 조합하여 총 6개(15S, 15L, 25S, 25L, 35S, 35L) 처리를 하였다. 초장이 0.5cm인 오이묘 '아시아 은천'을 양질사토로 충진한 1L 원형 포트에 정식하여 21일간 처리하였다. 처리 14일째 광합성, 증산율과 기공전도도는 25S에서 가장 높았고, 관수 주기가 짧은 S처리에서 L처리보다 높았다. 처리 기간 중 총 관수량이 2L로 동일하게 공급되었지만 토양함수율은 15S에서 가장 높았고 25S > 15L > 25L, 35S, 35L 순으로 낮았다. 상대습도는 15/10℃(61.1%)와 25/20℃(67.2%)는 비슷한 경향을 보였지만 35/25℃에서는 80.5%로 높았다. 21일째 오이 생육은 25S에서 가장 높았고, 초장, 생체중과 건물중은 관수 주기에 영향을 받았다. 잎끝황화 현상은 온도가 높았던35S, 35L에서 89.9% 발생하였다. 상대생장률(RGR)과 비엽중(SLA)은 25/20℃(25S, 25L)에서 높았고, RGR은 관수 주기가 짧은 S처리, SLA은 L처리에서 높은 경향을 보였다. 수분이용효율(WUE)은 25S, 25L > 15S > 15L, 35S, 35L 순으로 높았다. 이상의 결과 적온인 25/20℃에서 생육과 수분이용효율도 높았다. 그러나 35/25℃(35S, 35L) 처리에서는 토양 함수량이 낮았고, 잎끝 황화현상이 발생하였으며, 15/10℃(15S, 15L)에서 토양 함수율이 높고 광합성과 생장이 낮았다.
연구의 최종 목표는 실내의 공간과 특성에 따라 효율적으로 실내공기질을 향상시킬 수 있는 식물 녹화와 바이오필터를 통합한 시스템의 개발이다. 그러나 이러한 목표를 달성하기 위해서는 바이오필터 시스템의 적절한 공기정화량에 대한 용량 설계에 중요한 영향을 주는 일정한 압력손실량과 토양수분 함량과 같은 여러 가지 요구사항들이 충족되어야 한다. 따라서 본 기초 연구는 바이오필터의 토양 내 균일한 분포를 갖는 토양수분 함량과 압력손실량을 유지하고 정상적인 식물 생장 특히 바람에 의한 근권부 스트레스를 받지 않도록 풍속을 적절히 조절하고, 바이오필터 내 초기 토양수분 함량이 일정하게 유지되어 안정성을 확보하기 위해 수행되었다. 본 실험에서는 평면형 바이오필터 모델을 설계하여 제작하고 세 가지 풍속(1, 2, $3cm{\cdot}sec^{-1}$)에 따른 바이오필터의 공기정화량, 공기체류시간, 기액비를 산출하였다. 또한 세가지 풍속에 따라 바이오필터 내 토양층을 통과하여 배출된 가습공기의 상대습도, 압력손실량, 토양수분 함량을 측정하고, 이 바이오필터 내에서 자란 상추와 더 피고사리의 생육을 평가하였다. 풍속 실험의 결과, 풍속 $3cm{\cdot}sec^{-1}$가 상대습도, 토양수분 함량, 식물생육을 유지하기에 가장 적절하였다. 따라서 다음 실험에서는 풍속을 $3cm{\cdot}sec^{-1}$로 고정하고 두 가지 수준의 초기 토양수분 함량(저수준 18.5%, 고수준 28.7%) 조건에서 바이오필터를 가동한 처리구와 바이오필터를 가동하지 않은 대조구(초기 토양수분 함량 29.7%)를 설정하고, 바이오필터 내 토양층을 통과하여 배출된 가습공기의 상대습도, 압력손실량, 토양수분 함량과 바이오필터 내에서 자란 상록넉줄고사리의 생육을 평가하였다. 이 실험 결과는 첫 번째 실험 결과와 유사하였으며 상대습도, 토양수분 함량, 압력손실량이 일정한 수준을 유지하였다. 또한 세 가지 초기 토양수분 함량에 따른 상록넉줄고사리의 생육도 유의성 있는 차이를 나타내지 않았다. 그러나 두 가지의 바이오필터 처리구는 대조구에 비해 건물중이 다소 증가된 것을 알 수 있었다. 따라서 주요 물리적 요소인 토양수분 함량과 압력손실량을 유지할 수 있는 본 바이오필터 시스템의 안정성은 가까운 미래에 보다 발전된 일체형 바이오필터 모델 설계에 적용될 수 있을 것으로 판단된다.
International Journal of Industrial Entomology and Biomaterials
/
제18권2호
/
pp.105-112
/
2009
The greenhouse whitefly, Trialeurodes vaporariorum (Westwood) and the sweet potato whitefly, Bemisia tabaci (Gennadius) are serious insect pests that have a wide host range including cucumber, tomato, and pepper. In this study, we tested larvicidal efficacy of several on-the-market environment-friendly agricultural materials (EFAM) to select the effective products after the target pests were stabilized in indoor rearing condition. The developmental periods of two whiteflies are as follows: in the case of T. vaporariorum, egg duration is 9.6 days and nymph is 18.9 days, and in the case of B. tabaci, egg duration is 7.4 days and nymph is 15.2 days under $25^{\circ}C$ with relative humidity (RH) of $60{\pm}5%$ and a photoperiod of 16 L:8D. The total period of T. vaporariorum was 5 days longer than B. tabaci. Among 22 EFAMs six products showed more than 60% of insecticide efficacy against T. vaporariorum BTV B, BTV D, BTV G, BTV L, BTV M, and BTV S. On the other hand, seven EFAM products showed over 60% of insecticide efficacy against B. tabaci BTV D, BTV G, BTV K, BTV L, BTV M, BTV N, and BTV U. In the case of Spodptera litura previously, 16 EFAMs were tested against $2^{nd}$ instar S. litura, and six EFAMs were found to have more than 90% efficacy. Test of these six EFAMs against entire larval stages were performed in this study. Although some of these products showed still more than 90% of insecticidal efficacy against up to $3^{rd}$ instar larvae, the efficacy of these EFAMs sharply decreased as ages increase, resulting in less than 60% of efficacy of the products at most. This result indicates the difficulty to control S. litura with the on-the-market EFAMs alone under economic injury level. Collectively, it is required to find more EFAMs, and find alternative method, and combined way of controlling to control those insect pests tested in this study.
여름철에 파프리카 코이어 배지경에서 'Cupra', 'Piesta' 2품종을 공시하여 시설 내 포그냉방 효과에 의한 파프리카 생육을 검토코자 하였다. 시설 내 포그 냉방처리를 통해 무처리보다 온실 내의 온도가 $2{\sim}3^{\circ}C$ 낮았으며 최고온도를 $35^{\circ}C$이하로, 그리고 실내습도도 80% 내외로 유지할 수가 있었다. 초장, 엽수 등 생육은 포그냉방 처리구가 무처리에 비해 양호하였다. 평균과중은 두 품종 모두 포그냉방 처리구에서 158~160g으로 무처리보다 무거웠고, 주당 착과수는 'Cupra', 'Piesta' 모두 포그냉방 처리구가 각각 18.4, 18.3개로 무처리에 비해 7~8개 많았다. 상품수량은 'Cupra', 'Piesta' 두 품종 모두 포그냉방 처리구가 각각 6,027, 5,890kg/10a으로 무처리에 비해 유의적으로 많았다. 과실의 당도는 처리간에 차이가 없었으며 'Cupra', 'Piesta' 두 품종 모두 $5{\sim}6^{\circ}Bx$ 였으며 과육의 두께는 포그냉방 처리 효과가 없었다. 과실의 열과 발생률은 포그냉방 처리구가 낮았으며 품종 간에는 차이가 없었다. 이상의 결과에서 여름철 파프리카 수경재배시 포그냉방으로 시설내 온도의 강하와 습도조절이 가능하였으며 그에 따른 결과, 생육이 양호하며 과실의 품질 또한 좋아짐을 알 수 있었다.
본 연구에서는 에너지절감과 실내쾌적성을 높이기 위하여 색온도, 아로마 및 소리 변동리듬의 자극을 가하여 비교분석하였다. 온도$25[^{\circ}C]$, 상대습도 50[RH%], 기류속도 0.02[m/s] 및 조도 1000[lux]가 유지되는 항온항습실에서 뇌파, 심박동 변이 및 바이브라이미지가 측정되었다. 자극 종류는 자극을 가하기 전, 소리 변동리듬 a=1.106 재즈 음원으로 이루어지는 단일자극 그리고 붉은 조명, 아로마향기 및 소리 변동리듬 a=1.106 재즈 음원으로 이루어지는 다감각자극의 세종류로 측정이 이루어졌다. 변동리듬 a=1.106의 재즈 음원, 붉은 조명 및 아로마향기의 다감각자극에서 생산성과 집중력이 향상되었고, 스트레스지수와 피로도가 감소되었다. 또한 변동리듬 a=1.106의 재즈음원, 붉은 조명 및 아로마향기의 다감각자극에서 심박동이 안정되게 유지되었으며, 바이브라이미지의 긴장도와 스트레스 역시 감소되었다. 변동리듬 a=1.106 음원, RED조명 및 쟈스민 향기의 다감각자극이 쾌적성과 집중력 향상에 효과적이라는 것을 알 수 있었으며, 단일감각에 노출되기 전보다 뉴로에너지가 증가한다는 것을 알 수 있었다. 변동리듬 a=1.106 음원, RED조명 및 쟈스민 향기의 다감각자극이 자극을 가하기전보다 또한 단일감각자극을 가했을 때 보다 뉴로에너지가 증가된다는 것을 알 수 있었다.
환기는 자연환기와 강제환기로 분류되며, 최근에는 하절기에 작업장의 환경개선을 위해 냉각된 공기를 공급하는 환기를 적용하는 경우가 많아지고 있다. 하지만 대규모의 작업장에 냉각된 공기를 공급하기 위해서는 많은 에너지가 필요하며, 이를 보완하기 위해 물의 증발열을 이용하여 공기를 냉각시킨 후 공급하는 환기장치의 도입사례가 증가하고 있으며, 본 실험연구는 부산의 모 신발공장에 실제 적용된 기화방열식 환기장치의 성능을 평가한 사례연구로서 하절기에 외부의 대기온도에 대해 어느 정도의 냉각능력을 구현할 수 있는지 측정하였다. 실험결과로부터 하절기에 약 $6{\sim}7^{\circ}C$ 정도의 냉각효과를 구현하지만 급기의 상대습도가 매우 높아짐을 정량적으로 측정할 수 있었다. 실험결과에 의하면 기화방열식 전체환기 설비가 타방식과 비교하여 작동방식이 단순하며, 에너지 소비가 적은 경제적인 냉각설비이며, 급기의 습도 제어기능만 부가되면 매우 효율적인 환기 - 냉각기능을 동시에 수행할 수 있는 설비임을 확인하였다.
UV-TiO$_2$ 광촉매를 이용한 공기 정화 시스템에 운전조건에 대한 연구가 수행되었다. 이 연구에서 시스템의 운영 조건이 바뀜에 따른 오염물질 제거 특성을 관찰하기 위해 덕트 형태의 반응기를 제작하고, 스테인레스 격자망에 TiO$_2$를 코팅하였다. 또한 benzene을 이용하여 UV/TiO$_2$ 공정으로 유입농도를 변화시키고, 반응기로 들어오는 유량을 조절하여 TiO$_2$를 코팅한 스테인레스 격자망을 부착한 평판에서의 유속을 변화시켰으며, 코팅한 TiO$_2$ 광촉매량을 변화시키고, 일정한 양의 TiO$_2$ 광촉매를 코팅한 면적을 변화시켰으며, UV light intensity를 변화시켜 그에 따른 영향을 관찰하였다. 모든 실험에서의 상대습도는 55%, 반응기 온도는 45$^{\circ}C$를 유지하였다. 실험의 결과를 살펴보면, benzene의 유입농도가 증가할수록 제거효율이 감소하였고, 유속이 느려질수록, 즉 농도 경계층 두께(concentration boundary layer thickness)가 증가할수록, 코팅한 광촉매량, 광촉매를 코팅한 면적, 조사한 UV 램프의 intensity가 증가할수록 benzene 제거효율이 증가하였다. 본 연구 자료를 바탕으로 실내 공기 중 저농도의 VOCs를 대상으로 공기 정화 시스템을 설계할 경우 유용하게 적용할 수 있는 자료를 제시할 수 있다고 판단된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.