• Title/Summary/Keyword: indoor positioning system

Search Result 324, Processing Time 0.021 seconds

A Space Skew and Crosstalk Cancellation Scheme Based on Indoor Spacial Information Using Self-Generating Sounds (자체발성음을 이용한 실내공간정보 획득 및 공간뒤틀림/상호간섭 제거기법)

  • Kim, Yeong-Moon;Yoo, Seung-Soo;Lee, Ki-Seung;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2C
    • /
    • pp.246-253
    • /
    • 2010
  • In this paper, a method of removing the space skew and cross-talk cancellation is proposed where the self-generated signals from the subject are used to obtain the subject's location. In the proposed method, the good spatial sound image is maintained even when the listener moves from the sweet spot. Two major parts of the proposed method are as follows: listener position tracking using the stimuli from the subject and removal of the space skew and cross-talk signals. Listener position tracking is achieved by estimation of the time difference of arrival (TDoA). The position of the listener is then computed using the Talyer-series estimation method. The head-related transfer functions (HRTF) are used to remove the space skew and cross-talk signals, where the direction of the HRTF is given by the one estimated from the listener position tracking. The performance evaluation is carried out on the signals from the 100 subjects that are composed of the 50 female and 50 male subjects. The positioning accuracy is achieved by 70%~90%, under the condition that the mean squared positioning error is less than $0.07m^2$. The subjective listening test is also conducted where the 27 out of the 30 subjects are participated. According to the results, 70% of the subjects indicates that the overall quality of the reproduced sound from the proposed method are improved, regardless of the subject's position.

Positioning-error Analysis of Vibration Sensors for Prognostics and Health Management in Rotating System (갠트리 크레인 호이스트의 건전성 평가를 위한 진동 모사시스템 구축과 데이터 통계 분석)

  • Jang, Jaewon;Han, Zhiqiang;Zhang, Haiyang;Oh, Daekyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.346-353
    • /
    • 2022
  • Recently, studies on the integrity of rotating machines, such as gantry cranes, which are used in the shipbuilding industry, have been actively conducted. Gantry cranes are driven at relatively low revolutions per minute (RPM), are frequently operated and stopped, and are impacted by external environmental factors, such as shock and noise in the measurement data. The purpose of this study was to construct a replica of a gantry crane hoist used in indoor shipbuilding and analyze the acquired data for errors caused by the shift in operating conditions (RPM) and the change in the position of the data acquisition sensor. Consequently, we observed that the error caused by differences in sensor positions did not occur significantly under low operating conditions but occurred significantly under relatively high operating conditions. Thus, we determined that both the operating condition and position of the acquisition sensor affected the data acquired by the rotary machine.

Localization Using Extended Kalman Filter based on Chirp Spread Spectrum Ranging (확장 Kalman 필터를 적용한 첩 신호 대역확산 거리 측정 기반의 위치추정시스템)

  • Bae, Byoung-Chul;Nam, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.45-54
    • /
    • 2012
  • Location-based services with GPS positioning technology as a key technology, but recognizing the current location through satellite communication is not possible in an indoor location-aware technology, low-power short-range communication is primarily made of the study. Especially, as Chirp Spread Spectrum(CSS) based location-aware approach for low-power physical layer IEEE802.15.4a is selected as a standard, Ranging distance estimation techniques and data transfer speed enhancements have been more developed. It is known that the distance measured by CSS ranging has quite a lot of noise as well as its bias. However, the noise problem can be adjusted by modeling the non-zero mean noise value by a scaling factor which corresponds to the change of magnitude of a measured distance vector. In this paper, we propose a localization system using the CSS signal to measure distance for a mobile node taken a measurement of the exact coordinates. By applying the extended kalman filter and least mean squares method, the localization system is faster, more stable. Finally, we evaluate the reliability and accuracy of the proposed algorithm's performance by the experiment for the realization of localization system.

3D Reconstruction of Pipe-type Underground Facility Based on Stereo Images and Reference Data (스테레오 영상과 기준데이터를 활용한 관로형 지하시설물 3차원 형상 복원)

  • Cheon, Jangwoo;Lee, Impyeong
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1515-1526
    • /
    • 2022
  • Image-based 3D reconstruction is to restore the shape and color of real-world objects, and image sensors mounted on mobile platforms are used for positioning and mapping purposes in indoor and outdoor environments. Due to the increase in accidents in underground space, the location accuracy problem of underground spatial information has been raised. Image-based location estimation studies have been conducted with the advantage of being able to determine the 3D location and simultaneously identify internal damage from image data acquired from the inside of pipeline-type underground facilities. In this study, we studied 3D reconstruction based on the images acquired inside the pipe-type underground facility and reference data. An unmanned mobile system equipped with a stereo camera was used to acquire data and image data within a pipe-type underground facility where reference data were placed at the entrance and exit. Using the acquired image and reference data, the pipe-type underground facility is reconstructed to a geo-referenced 3D shape. The accuracy of the 3D reconstruction result was verified by location and length. It was confirmed that the location was determined with an accuracy of 20 to 60 cm and the length was estimated with an accuracy of about 20 cm. Using the image-based 3D reconstruction method, the position and line-shape of the pipe-type underground facility will be effectively updated.