Heating Performance Analysis of Building Integrated Geothermal System (건물일체형 지열히트펌프시스템의 난방 성능 분석)

  • Jin, Shangzhen;Lee, Jin-Uk;Kim, Tae-Yeon;Leigh, Seung-Bok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF

Generation and Detection of Discharge Signals in Deteriorated (열화된 저압용 콘센트에서 방전신호의 발생과 검출)

  • Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Kil, Gyung-Suk;Cho, Young-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF

Detection and Identification of the Series Arc in an Indoor Wiring System (옥내 배선계통에서 직렬 아크의 검출과 판별)

  • Kim, Woo-Hyun;Wang, Guoming;Kil, Gyung-Suk;Ji, Hong-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.412-416
    • /
    • 2018
  • Most series arcs lead to electrical fires that cannot be interrupted by circuit breakers, because the arc's current is outside the breaker's operating range. In this paper, experiments were conducted on the detection and identification of series arcs to prevent electrical fires. Plugs and outlets specified in KS C 8305 were deteriorated to replicate arc faults commonly found in fields. The characteristics of series arcs resulting from various types of loose connections were determined by analyzing the frequency spectra and phase distributions of detected arc pulses. The results showed that the simulated arc defects used in this study were more similar to actual arc phenomena than the existing arc generator specified in UL 1699. In addition, loose connections, such as wire-wire, terminal-wire, and outlet-plug, can be identified by phases of $0^{\circ}$, $180^{\circ}$ and $360^{\circ}$, respectively. These phases can be detected by a band pass filter with a frequency range of 5~10 MHz, which can be used as the trip signal for circuit breakers.

A Study on the Effect of Open and Closed Room Doors on Apartment Ventilation Characteristics (공동주택에서 각 실 문의 개폐에 따른 환기 특성 연구)

  • Choi, Im-Kyoo;Kim, Young-Il;Chung, Kwang-Seop
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.469-474
    • /
    • 2008
  • The objective of this study is to propose basic design guidelines for more effective air ventilation system in apartments. It is well known that ventilation depends on whether the room doors are open or closed as well as people's living patterns. This study considers 84 ㎡-sized apartment which has extended living room without balcony. Ventilation of bathroom and kitchen is not considered. The height of the building, external air pressure and air infiltration through the windows are also neglected. The regulation on indoor air quality made it mandatory that the air change per hour be more than 0.7. Four models are suggested to study the effect of open and closed doors. Models 1 and 3 are open door types and models 2 and 4 are closed door types. The open types have 50 mm hole near the top of the door to substitute exhaust outlet. The ventilation effectiveness was evaluated by 3-dimensional numerical simulation using finite volume method by a commercial software. This work compares air flow, temperature of air, age of air and the efficiency of ventilation of apartments with wooden doors of bedroom 1 and 2, which are open or closed.

  • PDF

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.