A Study on the Evaluation Methods of Indoor Thermal Comfort Index in Building (실내(室內) 온열환경지표(溫熱環境指標)의 평가방법에 관한 연구)

  • Jeong, Chang-Won;Horikoshi, Tetsumi;Yoon, In;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.11-21
    • /
    • 1999
  • This objective of this paper is to investigate the evaluation and indiction of human thermal comfort in building environment. The issue of defining the boundaries of acceptable thermal comfort conditions in buildings and urban may have significant implication for building design and also may have urban design by climate considerations. And then it is to apply the thermal comfort condition to environmental design by using passive methods in Korea. Since 1920. architects have conducted studies to measure thermal comfort in houses under hot and humid conditions, while industrial hygienists have studied the effects of temperature and humidity on the performance of factory workers. Thermal comfort can be influenced by many variables. This paper conducted to review the previous researches and the human heat balance equation, and to analyse in order to reveal the meaning and usage of the thermal comfort index in two traditional essays, Fanger's PMV and Gagge's ET* Their comfort indexes compared with each other. They were based on human heat balance equation and psychological and physiological responses in the laboratory tests. The researchers and the architectural engineers using thermal comfort index shall be careful in decided the use of indexes and be necessary to recognize the value concept of the design criteria for thermal comfort. Therefore, The opinion of the authors is that different comfort standards have to apply for each building and urban with different climatic conditions.

  • PDF

Integrated Command System for Firefight Satety in Special Disaster Area (특수재난현장 진압대원의 안전을 위한 통합 지휘시스템에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.98-108
    • /
    • 2015
  • An integrated command system is critical for the safety of firefighters and effective work in the headquarters of a special disaster areas such as natural disaster or large man-made hazard. The integrated command system requires environmental information such as temperature, humidity, and $CO_2$ levels, as well as personal physical information such as pulse and air respirator levels. An Analog to Digital Converter (ADC) chip converts sensed information into digital signals, and a Micro Controller Unit (MCU) transmits the digital signals to a transmission board using serial communication through a Serial Peripheral Interface (SPI). The digital signals are saved in a transmission board and transmitted to the integrated command system by a Radio Frequency (RF) unit. The location of fire-fighters in a building are determined using a gyro sensor and an inertial sensor. The collected information is applied to the integrated command system for firefighter safety and to ensure that they can effectively carry out their duties. Tthis study theoretically and experimentally investigated the technologies of RF transmission, indoor position, and an integrated command system that supports decision making using the transmitted information.

Effectiveness of education for control of house dust mites and cockroaches in Seoul, Korea

  • JEONG Kyoung Yong;LEE In-Yong;LEE Jongweon;REE Han-Il;HONG Chein-Soo;YONG Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.1 s.137
    • /
    • pp.73-79
    • /
    • 2006
  • We evaluated the efficacy of health education in reducing indoor arthropod allergens in Seoul. The mite control measures comprised the use of mite-proof mattress and pillow coverings, regular washing of potentially infested materials, maintenance of a low humidity, removal of carpets, and frequent vacuum cleaning. Cockroach control measures included trapping, application of insecticides, and protecting food. Of 201 homes enrolled in October 1999, 63 volunteers were included in a 2-year follow-up survey between April 2000 and January 2002. Before intervention, the density of mites/g of dust varied greatly; 27.1/g in children's bedding, 20/g in adult bedding, 7.2/g on the floors of children's bedrooms, 6.8/g in sofas, 5.9/g on the floors of adult's bedrooms, 3.9/g on living room floors, 3.7/g in carpets, and 1.9 mites/g on kitchen floors. The predominant mite species and house percentages infested were; Dermatophagoides farinae $93\%$, D. pteronyssinus $9\%$, and Tyrophagus putrescentiae $8\%$. Comparing 1999 and 2001 infestations, before and after 25 mo of education, mite abundance was reduced by $98\%$, from 23.7 to 0.57 mites/g of dust. In 1999, cockroaches were detected in $62\%$ homes: $36\%$ Blattella germanica and $35\%$ Periplaneta spp., including $9\%$ double infestations of B. germanica and P. americana. Following intervention, cockroach infestation rates decreased to $22\%$ of houses in 2000 and $23\%$ in 2001. We conclude that continuous and repetitive health education resulted in the effective control of domestic arthropods.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Effect of Aeration on Fertilization and Sludge Accumulation of Pig Slurry (돼지분뇨 슬러리 액비화시 폭기가 액비특성 및 슬러지 형성에 미치는 영향)

  • Jeong, Kwang-Hwa;Khan, Modabber Ahmed;Lee, Myung-Gyu;Kim, Jung-Gon;Han, Duk-Woo;Kwag, Jung-Hun
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • Two types of reactors were set to investigate the change of characteristics of pig slurry by aeration during fertilization period. One system was equipped with air diffuser to supply oxygen to pig slurry for liquid fertilization, but there was no air diffuser in the other system. Air supply to the experimental systems was regulated by air flow meter. The reactors were set up in the laboratory to protect the pig slurry from external condition such as temperature and humidity changes. Maintaining optimal pH range in the experimental reactors is an important factor for liquid fertilization of pig slurry. In this study, pH ranges of aerobic reactor and anoxic reactor was 7.04~7.19 and 7.34~7.81, respectively. The temperature of aerobic reactors was $2{\sim}3^{\circ}C$ higher then indoor temperature. The amount of sludge accumulated at the bottom layer of non-aerated reactors was 4~5 times more than that of aerated reactors.

Residential Humidifying Element Made of Cellulose and PET Composite (셀룰로오스와 PET 복합체로 만들어진 가정용 가습소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • Humidifiers are used to control indoor humidity. Element-type humidifiers have the advantages of simple structure and low energy consumption, and Japanese products have been widely used for the humidifying elements. In this study, a new humidifying element made of cellulose and PET was developed, and the performance was compared with that of a Japanese element. The mass transfer rates and pressure drops were measured for an element installed at the entrance of a suction-type wind tunnel. The humidification efficiency of the new element was 2 to 4% greater and the pressure drop was 23 to 32% smaller compared to the Japanese element. The mass transfer effectiveness ($j_m/f$) of the new element is also 5 to 28% higher. However, the water absorption capacity was smaller than that of the Japanese element, meaning further development is needed.

Development and Evaluation of Functional Lab Gowns in Point of Thermoregulation and Thermal Comfort (기능성 실험 가운의 개발 및 평가 -체온조절 및 온열 쾌적성을 중심으로-)

  • 최정화;이주영;김소영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.292-302
    • /
    • 2004
  • The purpose of this study was to evaluate thermal properties of lab gowns developed from the point of safety and work efficiency. We evaluated thermal and subjective responses of subjects wearing functional new lab gowns (Type B, C, D) and a popular lab gown on the market (Type A). Type B was a new lab gown made of woven fabric with functional cuffs. Type C was a new apron made of woven fabric with arm protectors. Type D was a new lab gown made of non-woven material with functional cuffs and openings around the armpits. Temperature in the climatic chamber was set at 19$^{\circ}$C as an indoor temperature in winter and at 24$^{\circ}$C in summer. There were no significant differences in rectal temperature and heart rate among four types of gowns and between two air temperatures for 120 min. Mean skin temperature was much higher in the type A and B than in He type C and D (p .05). In the 19$^{\circ}$C air, clothing microclimate temperature on the back was the highest in the type B and was the lowest in the type C (p .05). Clothing microclimate humidity was not significant differences among gowns. In subjective .esponses, subjects perceived that Type B was the warmest gown in the 19$^{\circ}$C and the hottest and more humid in the 24$^{\circ}$C than other gowns. Inversely, type C was the coolest gown among four gowns. Both in the 19$^{\circ}$C and in the 24$^{\circ}$C, the Type D had gained most responses of being comfortable. In conclusion, the temperature difference of 5$^{\circ}$C was more of an influencing factor than the difference from four types of lab gowns. Secondly, we recommend the manufacturers to make lab gowns with functional cuffs for safety purposes. Thirdly, the spread of the type of apron with arm protector will contribute to increase of the frequency of wearing in summer. Fourthly, it is necessary to study continuously about lab gowns with non-woven materials for researchers exposed to toxic chemical and biological materials.

A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.

Degradation of Chlorinated Hydrocarbons via a Light-Emitting Diode Derived Photocatalyst

  • Jo, Wan-Kuen;Lee, Joon Yeob
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • In this study, the applicability of visible light-emitting-diodes (LEDs) to the photocatalytic degradation of indoor-level trichloroethylene (TCE) and perchloroethylene (PCE) over N-doped $TiO_2$ (N-$TiO_2$) was examined under a range of operational conditions. The N-$TiO_2$ photocatalyst was calcined at $650^{\circ}C$ (labeled N-650) showed the lowest degradation efficiencies for TCE and PCE, while the N-$TiO_2$ photocatalysts calcined at $350^{\circ}C$, $450^{\circ}C$, and $550^{\circ}C$ (labeled as N-350, N-450, and N-550, respectively) exhibited similar or slightly different degradation efficiencies to those of TCE and PCE. These results were supported by the X-ray diffraction patterns of N-350, N-450, N-550, and N-650. The respective average degradation efficiencies for TCE and PCE were 96% and 77% for the 8-W lamp/N-$TiO_2$ system, 32% and 20% for the violet LED/N-$TiO_2$ system, and ~0% and 4% for the blue LED/N-$TiO_2$ system. However, the normalized photocatalytic degradation efficiencies for TCE and PCE for the violet LED-irradiated N-$TiO_2$ system were higher than those from the 8-W fluorescent daylight lamp-irradiated N-$TiO_2$ system. Although the difference was not substantial, the degradation efficiencies exhibited a decreasing trend with increasing input concentrations. The degradation efficiencies for TCE and PCE decreased with increasing air flow rates. In general, the degradation efficiencies for both target compounds decreased as relative humidity increased. Consequently, it was indicated that violet LEDs can be utilized as energy-efficient light sources for the photocatalytic degradation of TCE and PCE, if operational conditions of N-$TiO_2$ photocatalytic system are optimized.

Development of an Artificial Neural Network Model for a Predictive Control of Cooling Systems (건물 냉방시스템의 예측제어를 위한 인공신경망 모델 개발)

  • Kang, In-Sung;Yang, Young-Kwon;Lee, Hyo-Eun;Park, Jin-Chul;Moon, Jin-Woo
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: This study aimed at developing an Artificial Neural Network (ANN) model for predicting the amount of cooling energy consumption of the variable refrigerant flow (VRF) cooling system by the different set-points of the control variables, such as supply air temperature of air handling unit (AHU), condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. Applying the predicted results for the different set-points, the control algorithm, which embedded the ANN model, will determine the most energy efficient control strategy. Method: The ANN model was developed and tested its prediction accuracy by using matrix laboratory (MATLAB) and its neural network toolbox. The field data sets were collected for the model training and performance evaluation. For completing the prediction model, three major steps were conducted - i) initial model development including input variable selection, ii) model optimization, and iii) performance evaluation. Result: Eight meaningful input variables were selected in the initial model development such as outdoor temperature, outdoor humidity, indoor temperature, cooling load of the previous cycle, supply air temperature of AHU, condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. The initial model was optimized to have 2 hidden layers with 15 hidden neurons each, 0.3 learning rate, and 0.3 momentum. The optimized model proved its prediction accuracy with stable prediction results.