• Title/Summary/Keyword: indoor building materials

Search Result 271, Processing Time 0.026 seconds

A Study on The Evaluation Criteria of Carbon Emission and the Development of the Evaluation Method in Apartment House (공동주택을 대상으로 한 탄소배출 평가기준 구축 및 평가방법 개발)

  • Choi, Doo-Sung;Chun, Hung-Chan
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.79-88
    • /
    • 2013
  • This study creates the evaluation criteria to analyze the $CO_2$ emission quantity in the complex of apartment house among domestic buildings and proposes how to calculate the $CO_2$ emission quantity by the only simple information of apartment house. The study shows that in order to create the index of carbon emission evaluation criteria, $CO_2$ emission quantity for its input materials in these 27 apartment houses are 445,412g-$CO_2/m^2$ for apartment building, 474,322g-$CO_2/m^2$ for the basement parking lot, 483,523g-$CO_2/m^2$ for welfare facility, 729,957g-$CO_2/m^2$ for sales facility, 743,560g-$CO_2/m^2$ for other facility, 26,782g-$CO_2/m^2$ for public facility, 43,659g-$CO_2/m^2$ for landscape, 1,113g-$CO_2/m^2$ for indoor facility, 11,251g-$CO_2/m^2$ for outdoor facility and 891g-$CO_2/m^2$ for common temporary based on the average $CO_2$ emission by facility. We can also see the analysis data that in case of using the selected factors only, the rate of error is 7.51% comparing with the emission quantity by using simplified LCA method this study suggests for the whole range of apartment houses and the rate of error is average 3.24% using selective and main materials. And this it is evaluated that we can get the result which is similar to the actual $CO_2$ emission quantity with only the simple information about the apartment house.

Biological Effects of Volatile Organic Compounds from Carpet Materials as Assessed by the Tradescantia Assay (자주달개비 분석법을 이용한 카펫 방출 휘발성 유기화합물의 생물학적 영향 평가)

  • Kim, Jin-Kyu;Shin, Hae-Shick;Lee, Young-Yup;Lee, Jin-Hong
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.3
    • /
    • pp.191-196
    • /
    • 2007
  • Indoor air differs from outdoor atmosphere since it contains chemical and physical contaminants from building materials. This study deals with the biological effects of volatile organic compounds (VOCs) released from synthetic fiber carpet materials. One group of Tradescantia inflorescence was exposed to VOCs from the carpet sample in the environmental test chamber, while the other inflorescence group was exposed to a TO-14 standard gas mixture (1 ppm) for comparison. After the exposure, VOCs from the carpet were analysed by the desorber/GC/MS method, and micronuclei in the pollen mother cells of Tradescantia were scored under a microscope $({\times}400)$ to evaluate the genotocixicity induced by the exposure to VOCs. The chemical analysis confirmed that a total of 12 VOCs were released from the carpet materials, among which stylene $(71.9{\mu}g\;m^{-3})$ and toluene $(49.6{\mu}g\;m^{-3})$ were in the highest concentration. Twenty four hours of exposure to VOCs from the carpet in the environmental test chamber resulted in a micronucleus frequency as high as $7.73{\pm}0.75MCN$ per 100 tetrads, which was similar to that induced after exposure to the TO-14 standard gas mixture (1 ppm) for 4 hours. Meanwhile, two hours of exposure to the standard gas mixture did not cause a significant increase in the genotoxicity compared to the spontaneous micronucleus frequency. This result indicates that exposure for a long time to the air contaminated with VOCs from the carpet materials causes a genotoxic effect. The biological-chemical combination analyses in the study proved to be an effective tool for monitoring the indoor air contaminants.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

Pore Characterisitics and Adsorption Performance Evaluation of Magnesium Oxide Matrix by Active Carbon Particle Size (활성탄소 입도에 따른 산화마그네슘 경화체의 공극특성과 흡착성능 평가)

  • Pyeon, Su-Jeong;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2018
  • Radon gas is a colorless, odorless, tasteless gas that occurs when uranium, a natural radioactive material in rocks and soils, collapses. 85% of the annual radiation exposure of the human body is due to natural radiation, of which 50% is radon. According to the US Environmental Protection Agency (EPA) survey, 62 out of 1,000 smokers and 7 out of 1,000 nonsmokers are exposed to lung cancer when exposed to radon gas for a long time. In order to reduce the risk of radon gas, activate carbon was used to fabricate matrix, and the pore properties and radon reduction properties were investigated. When the activate carbon was used, the radon gas concentration was drastically reduced and the graph was changed as the measurement period became longer. The pore distribution and microporous properties, which are one of the material properties of activate carbon, can be grasped.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Daylighting Performance Evaluation of Light-shelf according to the Reflectivity - Focused on the Residing space - (반사율에 따른 광선반 채광 성능평가 연구 - 주거공간을 중심으로 -)

  • Heo, Doyeon;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: Due to recent increase on energy consumption for light in building, many studies to mitigate this issue have been conducted. Various researches have been carried out to suggest light shelf as one of the solutions, but researches for its reflectivity is very few. In fact, existing research on light shelf shows that utilizing more than 90% of high-illumination materials causes imbalance of glare and illuminance. Method: Therefore this research aimed to evaluate the performance of light shelves depending on reflectivity and to identify proper solution through test-bed. Result: The results are following: 1) Increased reflectivity generally contributed to increase of indoor illuminance but degrade uniformity factor related with indoor comfort of light environment. 2) The $0^{\circ}fixed$ light shelf with 75% of reflectivity and width of 300mm and 40mm appeared to consume more energy than other shelves. Therefore, it is analyzed as unsuitable. 3) This research was conducted by calculating appropriate angle of light shelf around winter and summer solstices and vernal/autumnal equinox. Based on this, performance evaluation was undertaken depending on reflectivity of movable light shelf, which is activated by external sources and can be applied with lower reflectivity than fixed shelf. However, one exception was a movable shelf with width of 600mm that increased light energy consumption when 75% of reflectivity was applied. 4) Performance evaluation of fixed and movable light shelf showed that the shelf with 80% of reflectivity came up with suitable results, but 75% of reflectivity may be applied depending on the width and angle of the shelf. This research is meaningful in that estimation of appropriate reflectivity of light shelf can resolve the glare problem and improve light environment, and further research would be desirable under more diverse conditions to identify proper solution.

Radon Concentration Assessment of Studio Apartments surrounding a University (대학가 주변 원룸의 라돈(radon) 농도 평가)

  • Lee, Seokyong;Lee, Youngmoo;Park, Jihyun;Kim, Sunshin;Hong, Gayeon;Ahn, Hogi;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.138-143
    • /
    • 2013
  • Objective: Building materials can generate radon in indoor environments. This study aims to assess the radon concentrations of studio apartments around a university. Methods: 25 studio apartments around a University in Gyoungsan, Korea were measured for concentrations of radon. We evaluated the radon concentrations by using short-term continuous radon monitors at the studio apartments around the university, and analyzed the correlation between indoor radon concentration and factors affecting it, such as year of construction. Results: The average concentration of radon was 2.03 pCi/L(75.11 $Bq/m^3$)${\pm}1.34$ in the studio apartments. This radon level was lower than the radon standard for public use facilities in Korea and US EPA's standard of 4 pCi/L. However the measured radon levels were much higher than those previously reported in conventional dwellings. There was a statistically correlation between year of construction and radon concentrations in studio apartment buildings. Conclusion: It is suggested that recently built studio apartments might be constructed with phosphogypsum board that features higher radon emissions, and occupants are highly exposed to radon.

Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 나노세라믹 필터의 성능 평가)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.