• Title/Summary/Keyword: indoor building materials

Search Result 269, Processing Time 0.026 seconds

A Bacteriological Study on the Indoor-Shoes, Desk and Bag of Student의s (실내화, 책상, 책가방의 위생학적 고찰)

  • Kong, Dong
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.26-33
    • /
    • 1977
  • A bacteriological research of the school desks, bags and indoor-shoes was made from Oct. 2, 197 through May 28, 1976. The research included one girl's middle school, two boy's middle schools, two boy's high schools and 15 girl's high schools, alltogether 244 students from 28 schools, The research was analyzed and the results are as follows: 1) The research showed that 95% of the indoor-shoes materials were of cloth. Only 13% of the students carried the indoor-shoes in shoes sacks and 84.8% of them kept the shoes in schoolbags with books and lunchbox. 2) Only 5% of them cleaned their shoes every week and 79% cleaned every six. 3) 49.3% of the students kept the indoor-shoes in the school bag with other contents at home. 4) 88% of the bag was made of vinyl and 24.8% of the students carried their lunch in their bag without lunch box. 5) The research showed that 79.1% of the students never cleaned their bags. 6) In using the desk drawer, 58.2% of the students put their out-door shoes into the drawer, 18.9% of them kept their lunch in it, 11.9% used it keeping books alone and 11% keeping school bags with books. 7) 30.4% of the students had an experience of having cleaned their desks and 69.6% were unconcerned wirh desk-cleaning. 8) 34.4% of the indoor-shoes using school showed fecal coliform positive, 40.2% showed non-fecal coliform positive and 25.4% showed no reaction to IMViC. 9) The 34.4% of the fecal coliform positive showing schools, equivalant to 77 students, was composed of zero percents of girl's middle school, 18.2% of girl's high school, 36.4% of boy's middle school and 45.4% of boy's high school. 10) Among the 77 students, whose shoes showed fecal coliform positive, only 6.5% of them cleaned their shoes once in a week or a month and 62.3% of them cleaned them once in a six month. 11) The fccal coliform positive rate was higher in the cloth shoes materials than the vinyl materials. 12) The concrete-bottomed building higher positive rate (40.2%) than the wood-bottomed building (7.5%). 13) Even among the student's who frequently cleaned their desk drawer, 2.3% were in the positive, and among those who were unconcerned with drawer cleaning, 48.9% were involved in the positive. 14) In the fecal coliform positive rate of bags, 38.5% of the positive rate belonged to using indoor shoes while cleaning their class bottom with water, 53.8% belonged to using outdoor shoes while cleaning their class bottom with water, 7.7% belonged to using outdoor shoes while cleaning their class with oil.

  • PDF

Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde- (신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로-)

  • Sim, Sang-Hyo;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.275-281
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. Especially exposure to indoor air can potentially pose a greater threat than exposure to ambient air when indoor environments have sources of contaminants. In this study, volatile organic compounds (VOCs) and formaldehyde (HCHO) within newly constructed apartment have been determined in 27 houses of apartment in Seoul from December 2004 to March 2005. The measured indoor air pollutants were HCHO, volatile organic compounds including benzene, toluene, styrene, xylene, ethylbenzene and sampled on the standard method of Ministry of Environment in Korea. The indoor levels for benzene, xylene, toluene, ethylbenzene, styrene, and HCHO have significant increase trend after 5 hours closing of windows and doors. Levels of measured air pollutants concentrations between living rooms and bedrooms have not shown significant difference. Spearman correlation coefficient among the measured air pollutants ranged from 0.303 to 0.946, indicating similar source in building materials.

Communication Performance of BLE-based IoT Devices and Routers for Tracking Indoor Construction Resources

  • Yoo, Moo-Young;Yoo, Sung Geun;Park, Sangil
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2019
  • Sensors collect information for Internet of Things (IoT)-based services. However, indoor construction sites have a poor communication environment and many interfering elements that make it difficult to collect sensor information. In this study, a network was constructed between a Bluetooth Low Energy (BLE)-based IoT device based on a serverless IoT framework and a router. This experimental environment was applied to large- and small-scale indoor construction sites. Experiments were performed to test the communication performance of BLE-based IoT devices and routers at indoor construction sites. An analysis of the received signal strength indication (RSSI) graph patterns collected from the communication between the BLE-based IoT devices and routers for different testbed site situation revealed areas with good communication performance and poor communication performance due to interfering factors. The results confirmed that structural components of the building as well as the materials, equipment, and temporary facilities used in indoor construction interfere with the communication performance. Construction project managers will require improved technical knowledge of IoT, such as optimizing the router placement and matching communication between the router and workers, to improve the communication performance for large-scale indoor construction.

A Study on Indoor Radon Concentration among Vulnerable Households in Korea (국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구)

  • Zoo, Duck Hyun;Park, Ki Ho;Jeong, Hui Won;Lim, Hyeong Jun;Bok, Dong Seok;Yun, Dong Won;Min, Kyung Hwan;Mun, Kyung Deok;Kim, Jeong Un;Lee, Ji Min;Choi, Won Yong;Kim, Sung Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.61-70
    • /
    • 2015
  • Objectives: The purpose of this research was to examine radon exposure in terms of the relationship between the living environment and indoor radon concentrations among vulnerable households. Methods: Nationwide, 1,129 subjects were selected using personal questionnaires for adequately understanding the living environment, installation of E-PERM radon gas detectors, and investigation of the structure of the housing. Results: The mean concentration of indoor radon for all subjects was $130.2Bq/m^3$ (GM=101.7), and a total of 438 subjects (38.8%) exceeded the recommended standards ($148Bq/m^3$) for public facilities by the Ministry of the Environment. By location, the highest concentrations ($164.3Bq/m^3$, GM=124.1) were seen in North Chungcheong Province. In the case of the Seoul/Gyeonggi Province metropolitan area, they showed $125.6Bq/m^3$ (GM=105.1) and $118.9Bq/m^3$ (GM=96.5), respectively. By type of housing, indoor radon concentrations in single-family housing were higher than in row/multi-family housing (p<0.01). Although indoor radon concentrations raised in accordance with year of construction (p<0.05), the difference between indoor radon concentrations in underground residences was not observed to be statistically significant (p=0.633). Conclusion: More studies are necessary in the future regarding the difference in indoor radon concentrations that may occur due to different of types of indoor construction, building materials, and the amount of building materials.

Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea (국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포)

  • Kim, Ki Youn
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

Impact Assessment of Remodeling Works on Indoor Air Quality in a University Library Building (대학 도서관 건물 리모델링에 따른 실내공기질 영향 평가)

  • Baek, Sung-Ok;Park, Dae-Gwon;Park, Sun-Young;Lee, Yeo-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.876-887
    • /
    • 2006
  • Recently, there have been a large number of remodeling (or renovation) works in old buildings in urban areas. Compared to new buildings, environmental risk might be more significant in such buildings where remodeling works are going on, since some parts of the building may still be in service for people. This study was carried out to investigate the impacts of remodeling works on the indoor air quality (IAQ) of a large building (a 22 stories university library). Indoor air monitoring was conducted during and after the remodeling works every two weeks for a one year period, and target compounds included BTEX, styrene, TVOC, carbonyl compounds such as formaldehyde and acetaldehyde. $CO,\;CO_2,\;PM_{10}$, and $PM_{2.5}$. Overall, the IAQ appeared to be recovered within two months after the remodeling works. However, in some places, concentrations of formaldehyde, toluene, xylene. and ethylbenzene showed higher levels even after works than those during the works. The results indicate that painting, glues and office furnitures are major sources of aromatic VOCs and formaldehyde. Therefore, in order to decrease the concentrations of toxic VOCs, the use of environmental-friendly building materials is strongly recommended during the remodeling works. In addition, IAQ control and management scheme (for example, baking the inside of the building) should be taken into consideration before reopening the buildings.

Analysis of Heat Transfer Characteristics by Material Based on Closed Conditions Using Acrylic Hemispheres (II): Comparison by Type of Building Structural Materials (아크릴 반구를 이용한 밀폐조건에 따른 재료별 열 이동특성 분석(II): 건축구조재 종류에 따른 비교)

  • YANG, Seung Min;KWON, Jun Hyuck;KIM, Phil Lip;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.710-721
    • /
    • 2020
  • This study used a building model made up of cement, brick, and wood to measure temperature and relative humidity for 3 days in a closed environment with a diameter of 900 mm, and performed a comparative analysis of the effect of types of building materials on the indoor temperature environment and heat transfer characteristics. The water installed inside the building model represented the person in the room and was used to assess how the environment effects the person. Wooden building model showed the lowest heat loss due to the higher thermal insulation properties than cement and brick buildings. The thermal comfort of each building model was calculated using temperature and relative humidity, and the wooden building model created a more pleasant environment than the cement and brick building models.

Heat Insulation Properties of Lightweight Magnesia Matrix According to Mixing Ratio of Anthracite (안트라사이트 치환율에 따른 경소마그네시아 경화체의 단열특성)

  • Pyeon, Su-jeong;Gwon, Oh-han;Kyoung, In-soo;Lee, Dong-hoon;Lee, Sang-soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.113-114
    • /
    • 2017
  • Recently, Subway workers have died from lung cancer. According to the Epidemiological Survey of the Welfare Corporation Institute of Pulmonary Disease of the Welfare Corporation, the family members applied for industrial accidents. The radon concentration in the subway work area was found to exceed 10 times the recommended standard value of 148 becquerels (Bq/㎥) in domestic multipurpose facilities. In addition, as a result of the national indoor radon concentration survey conducted by the Ministry of Environment in 2010 and 2013, housing was found to be over 100 becquerels (Bq/㎥) in 41% of the surveyed subjects. In addition, it was found that in 2012, 16.3% of villages exceeded the radon standard value in the survey on natural radioactive materials containing groundwater.

  • PDF

Design Strategy for Green Residential Building in Solar Decathlon - Based on Case Study of Residential Building in Solar Decathlon

  • Yoon, Sung-Hoon
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • The Purpose of this study is to analyze the green design strategies in residential building, based on case study of Solar Decathlon in USA. This study could provide the basic reference data and theocratical foundation for finding new green design strategies and applicability of green design for korea. The Solar Decathlon is an green design competition that challenges collegiate teams to design, build, and operate the green residential building with optimal energy production and maximum efficiency. As a result of the analysis of this study, the green design strategy is identified and analyzed design issues related in energy, materials, and indoor/outdoor environment. Also, it is useful to find best green design strategy with more economical and environmental benefits presented by renewable energy and design solutions. This study is based on selected 18 green housings of Solar Decathlon from 2002 to 2013. This result is helpful to understand the green design strategies for green residential building's design of modern residential building, and expect future green residential building design approach.

Development of Anti-Insect Mortar and Concrete using Microcapsule (마이크로 캡슐을 이용한 방충 기능성 모르타르 및 콘크리트의 개발)

  • 박석균;유완재;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.523-526
    • /
    • 2003
  • Functions of the building structures are recently expended, because the structures are getting larger and people's indoor staying times are getting longer. Therefore, various functional materials such as yellow mud, carbon soot, and jade are widely used. But functions of those materials have not permanent and continued an effect. Specially, the development of construction materials containing anti-insect is highly important to delight the environment of residence. This research try to examine to develop the mortar and concrete which contain microcapsules with long-term effect of anti-insect.

  • PDF