• Title/Summary/Keyword: indoor air pollution(IAP)

Search Result 3, Processing Time 0.023 seconds

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

Evaluation of Exposure Characteristics of Fine Dusts by Subway Lines (지하철역사의 호선별로 미세먼지의 노출특성에 대한 평가)

  • Hwang, Sung Ho;Kim, Jeong Oh
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Objectives: This study aimed to assess the environmental factors that affect particulate matters (PM10) and to compare with outdoor PM10 concentrations in an underground subway stations. Methods: The PM10 level was determined from May 2013 to September 2013 in the Seoul subway stations in four lines. PM mini-vol portable sampler sampler was used to collect PM10 for 6 hrs. Arithmetic means of PM10 concentrations with standard deviation (SD) were calculated. Paired t-test was used to compare the differences between indoor PM10 and outdoor PM10 concentrations with correlation analysis which was used to identify the association between indoor PM10 concentrations and environmental factors. Results: There were no different PM10 concentrations significantly between line 1, 2, 3 and 4 in an underground subway stations. Passenger number was positively associated with PM10 concentration while construction year was negatively associated with PM10 concentrations. Indoor PM10 concentrations were significantly higher than those in outdoor PM10 concentrations. PM10 concentrations were higher in the stations which were constructed before 1990s rather than the stations constructed after 1990s. Conclusion: PM10 levels in the underground subway stations varied greatly depending on the construction year. Therefore, it might need to be more careful management to the stations which constructed in before 1990s.

Associations Between Indoor Air Pollutants and Risk Factors for Acute Respiratory Infection Symptoms in Children Under 5: An Analysis of Data From the Indonesia Demographic Health Survey

  • Ichtiarini Nurullita Santri;Yuniar Wardani;Yohane Vincent Abero Phiri;Gunchmaa Nyam;Tyas Aisyah Putri;Khoiriyah Isni;Dyah Suryani;Grace Sambo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.3
    • /
    • pp.255-263
    • /
    • 2023
  • Objectives: The study investigated the association between indoor air pollution (IAP) and risk factors for acute respiratory infection (ARI) symptoms in children under 5 years of age. Methods: A cross-sectional study was conducted using data derived from Indonesia Demographic and Health Survey in 2017. Binary logistic regression modeling was employed to examine each predictor variable associated with ARI among children under 5 years of age in Indonesia. Results: The study included a total of 4936 households with children. Among children under 5 years old, 7.2% reported ARI symptoms. The presence of ARI symptoms was significantly associated with the type of residence, wealth index, and father's smoking frequency, which were considered the sample's socio-demographic characteristics. In the final model, living in rural areas, having a high wealth index, the father's smoking frequency, and a low education level were all linked to ARI symptoms. Conclusions: The results revealed that households in rural areas had a substantially higher level of reported ARI symptoms among children under 5 years old. Furthermore, the father's smoking frequency and low education level were associated with ARI symptoms.