• Title/Summary/Keyword: indoor air pollutant

Search Result 125, Processing Time 0.027 seconds

Indoor Ventilation Efficiency Depending on Diffuser Inlet Angle (급기구 유입각도에 따른 실내 환기효율)

  • Jeon, Hyun-Jun;Jang, Yong-Jun;Yang, Kyung-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.349-355
    • /
    • 2011
  • In this study, numerical simulation has been conducted to investigate dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and concentration fields. It is shown that the ventilation efficiency in this room can be improved by changing inlet angle of diffuser, even though other conditions still remain unchanged. Both active diffusion near a sofa and air flow pattern are important parameters to enhance the ventilation efficiency.

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

Assessment of Indoor Air Quality and the Eye Symptom of Occupants in Newly-built Office Building after Planting Indoor Plants (신축사무실 내 식물 적용 후 재실자 안구 증상 및 실내공기질 평가)

  • Kim, Hyojin;Kim, Ho-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.265-274
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate relationship between worker's ophthalmoxerosis symptom and IAQ (Indoor Air Quality) variation after planting indoor plants at newly-built office building. Methods: We selected a new office building located in Sejong-si and occupants who work in the Office for study. The indoor air pollutant was investigated according to applying indoor plants. The indoor air quality of the new building was evaluated by measuring volatile organic compounds (VOCs), aldehydes, temperature and humidity. The level of dry eye symptoms was classified into normal, mild, moderate and severe by using the Ocular Surface Disease Index (OSDI). Results: There was VOCs' reduction effect according to placing indoor plants because the concentration of VOCs in newly-built government office (Sejong-si) was highly decreased when the indoor plants was placed at the office. The occupants' SBS (Sick Building Syndrome) symptoms score was gradually decreased in accordance with applying indoor plants. However, SBS symptoms score was increased when the office was not applied indoor plants. There was not statistical significance in workers' dry eye questionnaire results. Conclusions: There was reduction effect of indoor air pollutant in applied indoor plants office. Also, in case of questionnaire results of ophthalmoxerosis and SBS (Sick Building Syndrome) symptoms score were showed positive effect. This study is needed longer-term study because of complements of difference of individual sensitivity and there are some limitations due to field survey research.

Plant Effects on Indoor Formaldehyde Concentration (실내 포름알데히드 농도에 미치는 식물의 영향)

  • Park, So-Young;Sung, Ki-June
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.197-202
    • /
    • 2007
  • Formaldehyde is a typical indoor air pollutant that has numerous adverse health problems in modern living conditions. Phytoremediation that use plants to remove contaminants from polluted media can be applied to improve indoor air quality. Two sets of experiments; 1) two rooms in newly built auditorium and 2) a bed room in 2-year-old apartment; were performed to investigate plant effects on indoor formaldehyde concentration. It was observed from the experiments that plant can help decontaminating formaldehyde at low concentration level (0.1 ppm) but the effects decreased considerably at hish concentration (1ppm). The purification effects of indoor plant also showed the periodic pattern due to its physiological activity. More purification was observed as increasing plant density in the bed room but the formaldehyde concentration returned the original concentration level in two days after removing plants. It was suggested from the results that air purification using plants is an effective means of reduction on indoor formaldehyde level, though, reduction of source is highly desirable when the concentration level is high. The results also suggest that introducing supplementary purifying aids and/or efficient ventilation could be considered due to periodic removal pattern of plant.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

The Study for Adsorption of Indoor Pollutants by Ocher and Diatomite Filter (황토와 다공성 규조토 필터에 의한 실내 오염 물질의 흡착 연구)

  • Kim, Ho-Keun;Irodakhon, Akhmadalieva;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.583-591
    • /
    • 2020
  • Environmental problems have showen over the past decades due to the rapid development of the world economy and the continued growth of the population. Ocher has been widely used for water treatment research, but few studies have been conducted on adsorption of air pollutants using ocher and porous diatomite earth for indoor air purification. In this study, ocher and diatomite earth were sintered with filters to remove indoor air pollutants. The four types of TMA, H2S, NH3 and CH3COOH were used to study the adsorption efficiency of ocher and porous diatomite filters. With the proper use of ocher, diatomite and copper catalysts, indoor air pollutants could be adsorbed. Alkaline substances (TMA and NH3) and acidic substances (H2S and CH3COOH) were able to adsorb at 120 and 90 minutes, respectively.

Gas Removal Characteristics of Air Clean System Applying a Magnetic Field (자계가 인가된 공기청정장치의 가스 제거 특성)

  • Shin, Soo-Youn;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.921-925
    • /
    • 2007
  • Gas removal characteristics of an air clean system, consisted of a filter and a nonthermal discharge plasma reactor with a magnetic field, have been investigated with emphasis on the enhancing gas removal efficiency of the applied magnetic field. It is found that the magnetic field influenced significantly to the corona discharge characteristics, decreasing the corona onset voltage and increasing the corona current. As a result, the proposed air clean system with the magnetic field showed the higher removal efficiency of the gas (e.g., trimethlyamine) than that of without the magnetic field. This would be because the magnetic field applied to the discharge plasma reactor of the air clean system can elevate the corona characteristics, and activate the generation of ozone, thus the removal efficiency of the gas was concurrently enhanced. This reveals that the proposed air clean system with the magnetic field could be used as an effective means of removal an indoor pollutant gas.

A Study on the Characteristics of Indoor Air Quality in Elevator (엘리베이터 실내공기질의 특성 기초조사)

  • Park, Jeong-Ho;Choo, Yeon-Gyu;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.