• 제목/요약/키워드: indirect-group

검색결과 554건 처리시간 0.033초

급성 족관절 염좌에 대한 침구병행 치료와 침 단독 치료 효과의 비교 연구 (The Comparative Study on the Effect of Acupuncture Treatment with or without Indirect Moxibustion Treatment for Acute Ankle Sprain)

  • 우창훈;권오곤;안희덕
    • 한방재활의학과학회지
    • /
    • 제20권1호
    • /
    • pp.141-152
    • /
    • 2010
  • Objectives : The purpose of this study is to compare with the effect of acupuncture treatment with or without indirect moxibustion treatment for acute ankle sprain. Methods : This study was carried out on the 48 patients who had been treated for acute ankle sprain from June 1st to November 30th 2009 in the Dept. of Oriental Rehabilitation, Pohang Oriental Medical Hospital, Daegu Hanny University. The patients were divided into 3 groups ; Group A took near acupuncture point_needling, Group B took remote acupuncture point needling, Group C took remote acupuncture point needling with indirect moxibustion. 3 Groups had been co-treated with rest, ice, compression and elevation(RICE) therapy, physical treatment and administered Ojeok-san(Wuji-san) extract granule. To evaluating the efficiency of each treatment, Ankle-Hindfoot Scale(AHS) and Visual Analogue Scale(VAS) were applied before treatment and after 3rd treatment. Results : In results, the AHS scores were increased and the VAS scores were decreased after 3rd treatment in all group. Also, AHS scores and the VAS scores of intergroup were showed no significant change. Conclusions : In this study, there is no significant effect between only acupuncture treatment and moxibustion co-treatment for acute ankle sprain.

간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구 (Research on composting of sewage sludge using dryer facility with indirect heating system)

  • 백선재;한인섭;최익훈;강성효;홍성민
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements

  • Sadighpour, Leyla;Geramipanah, Farideh;Ghasri, Zahra;Neshatian, Mehrnoosh
    • Restorative Dentistry and Endodontics
    • /
    • 제43권4호
    • /
    • pp.40.1-40.10
    • /
    • 2018
  • Objectives: This study evaluated the microtensile bond strength (${\mu}TBS$) of polymer-ceramic and indirect composite resin with 3 classes of resin cements. Materials and Methods: Two computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated polymer-ceramics (Enamic [ENA; Vita] and Lava Ultimate [LAV; 3M ESPE]) and a laboratory indirect composite resin (Gradia [GRA; GC Corp.]) were equally divided into 6 groups (n = 18) with 3 classes of resin cements: Variolink N (VAR; Vivadent), RelyX U200 (RXU; 3M ESPE), and Panavia F2 (PAN; Kuraray). The ${\mu}TBS$ values were compared between groups by 2-way analysis of variance and the post hoc Tamhane test (${\alpha}=0.05$). Results: Restorative materials and resin cements significantly influenced ${\mu}TBS$ (p < 0.05). In the GRA group, the highest ${\mu}TBS$ was found with RXU ($27.40{\pm}5.39N$) and the lowest with VAR ($13.54{\pm}6.04N$) (p < 0.05). Similar trends were observed in the ENA group. In the LAV group, the highest ${\mu}TBS$ was observed with VAR ($27.45{\pm}5.84N$) and the lowest with PAN ($10.67{\pm}4.37N$) (p < 0.05). PAN had comparable results to those of ENA and GRA, whereas the ${\mu}TBS$ values were significantly lower with LAV (p = 0.001). The highest bond strength of RXU was found with GRA ($27.40{\pm}5.39N$, p = 0.001). PAN showed the lowest ${\mu}TBS$ with LAV ($10.67{\pm}4.37N$; p < 0.001). Conclusions: When applied according to the manufacturers' recommendations, the ${\mu}TBS$ of polymer-ceramic CAD/CAM materials and indirect composites is influenced by the luting cements.

치과 치료학에서 적용되는 접합기술 연구 ; 스테인리스강 크라운에 접합된 직접용 콤포짓트 레진과 간접용 콤포짓트 레진의 전단결합강도 비교 (Comparison Study for the Shear Strength of the Bondings between Stainless Steel Crown/Direct Type Composite Resin and Stainless Steel Crown/Indirect Type Composite Resin)

  • 김광수;백광우
    • Journal of Welding and Joining
    • /
    • 제29권4호
    • /
    • pp.93-99
    • /
    • 2011
  • This study was performed to compare the shear strength of the bondings between stainless steel crown/direct type composite resin and stainless steel crown/indirect type composite resin. Four groups of bonding conditions were prepared. Two groups of bonding conditions were made by the indirect type composite resin system and the other two groups were made by the direct type composite resin system. The shear strength tests were carried out using universal testing machine, Model 4465 of Instron Co.. It was indicated that the bond strength values of the indirect type composite resins were higher than those of the direct type composite resins. TE-SE group was superior to the TE-ONE in indirect type resin system. These results were thought to be the high degree of the polymerization accompanied with temperature and pressure of the resin of indirect type resin. It was also found that indirect composite resin contains less amount of porosity in resin.

접착술식에 따른 전단강도 및 Bracket위치의 비교 (THE COMPARISON OF SHEAR STRENGTH AND BRACKET PLACEMENT BETWEEN BONDING TECHNIQUES)

  • 박윤경;국윤아;김상철
    • 대한치과교정학회지
    • /
    • 제21권3호
    • /
    • pp.513-520
    • /
    • 1991
  • The purpose of this study was to compare the bracket placement and the shear bond strength of indirect-bonded brackets with those of direct-bonded ones. Forty eight extracted human teeth were collected and attached with brackets and tested on shear bond strength, using Instron. Fourteen patients from Wonkwang University Dental Hospital were selected for direct bonding of brackets and their teeth were measured on bracket angulation and bracket height. The obtained results were as follows: 1. The shear bond strengths of incisors were higher in direct-bonding,group, rather than in-direct-bonding group. But, the shear bond strength of premolars showed no significant differences between groups. 2. The bracket angulations of indirect-bonding group were preciser than those of direct-bonding group, especially in upper first premolars, lower lateral incisors, canines, premolars. 3. In bracket height, there were no significant differences between groups.

  • PDF

Comparative study of the shear bond strength of various veneering materials on grade II commercially pure titanium

  • Lee, Eun-Young;Jun, Sul-Gi;Wright, Robert F.;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.69-75
    • /
    • 2015
  • PURPOSE. To compare the shear bond strength of various veneering materials to grade II commercially pure titanium (CP-Ti). MATERIALS AND METHODS. Thirty specimens of CP-Ti disc with 9 mm diameter and 10 mm height were divided into three experimental groups. Each group was bonded to heat-polymerized acrylic resin (Lucitone 199), porcelain (Triceram), and indirect composite (Sinfony) with 7 mm diameter and 2 mm height. For the control group (n=10), Lucitone 199 were applied on type IV gold alloy castings. All samples were thermocycled for 5000 cycles in $5-55^{\circ}C$ water. The maximum shear bond strength (MPa) was measured with a Universal Testing Machine. After the shear bond strength test, the failure mode was assessed with an optic microscope and a scanning electron microscope. Statistical analysis was carried out with a Kruskal-Wallis Test and Mann-Whitney Test. RESULTS. The mean shear bond strength and standard deviations for experimental groups were as follows: Ti-Lucitone 199 ($12.11{\pm}4.44$ MPa); Ti-Triceram ($11.09{\pm}1.66$ MPa); Ti-Sinfony ($4.32{\pm}0.64$ MPa). All of these experimental groups showed lower shear bond strength than the control group ($16.14{\pm}1.89$ MPa). However, there was no statistically significant difference between the Ti-Lucitone 199 group and the control group, and the Ti-Lucitone 199 group and the Ti-Triceram group. Most of the failure patterns in all experimental groups were adhesive failures. CONCLUSION. The shear bond strength of veneering materials such as heat-polymerized acrylic resin, porcelain, and indirect composite to CP-Ti was compatible to that of heatpolymerized acrylic resin to cast gold alloy.

3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰 (Evaluation of Flexural strength and surface porosity of three indirect composite resins)

  • 김준태;박진영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.

아연 및 알루미늄 용융도금 처리된 강판이 북방전복(Haliotis discus hannai)의 아가미와 간췌장에 미치는 영향 (Effects of Zinc and Aluminum Hot-dip Galvanized Sheet Steel on the Gill and Hepatopancreas of the Abalone Haliotis discus hannai)

  • 이치훈;박준영;이영돈
    • 한국수산과학회지
    • /
    • 제50권4호
    • /
    • pp.388-395
    • /
    • 2017
  • We investigated the toxicity of zinc and aluminum hot-dip galvanized sheet steel to abalone Haliotis discus hannai via changes in the gill and hepatopancreas using histological and transmission electron microscopy analysis. Experimental groups were composed of one control and four exposure conditions (direct or indirect exposure to zinc and aluminum hot-dip galvanized sheet steel). In the control group, aluminum exposure groups (direct and indirect), and indirect zinc exposure group, abalone mortality was not observed until the end of the experiment, and no histopathological changes were observed in the gill and hepatopancreas. However, the direct zinc exposure group exhibited 100% mortality. Ultrastructural analysis of the cytoplasm of ciliated and microvilli-bearing epithelial cells from gill filaments revealed electron-dense vesicles near the cell membrane and disruption of the nuclear membrane. We also observed swollen mitochondria and a loss of mitochondrial cristae. The hepatopancreas showed similar changes, and we detected highly electron-dense particles within the vesicles. These results suggest that abalone exposed directly to zinc hot-dip galvanized sheet steel experience acute toxicity, causing damage to cell organelles in the gill and hepatopancreas and, finally, inducing mortality.

전산 시스템이 도입된 일개 종합병원 간호단위의 간호시간 산정에 관한 연구 (A Study on the Nursing Time in Nursing Units in Hospital to Applied Computer System)

  • 장춘자;강익화;이은자;김병연;이민숙
    • 대한간호학회지
    • /
    • 제25권3호
    • /
    • pp.441-456
    • /
    • 1995
  • This study was done to determine direct and in-direct nursing time in nursing units in hospital to ap-plied computer system and expect that those results contribute to measure efficiency of nursing practice and planning of nursing manpower. The design for study was a descriptive study. The study results are as follows. 1. Patients admitted to the Internal Medicine and General Surgery units were grouped into four. Group Ⅰ, 32.9% of the total patients, consisted patients whose condition was considered minor Group Ⅱ, 26.1%, was of those whose condition was considered moderate, Group Ⅲ, 41. 8%, moderate severe and Group Ⅳ, 29.2% the most severe. 2. Nursing intervention times by care type were as follows four minutes spent for suction eight minutes, for simple position change, ten minutes, for sheet change, seven minutes for a hot or cool compress, six minutes for dressing change, four minutes for Ⅰ.M. injection, six minutes for patient health education and five minutes for body temperature check. 3. Direct care time by patient group revealed the following : Group Ⅰ rquired 191.4 minutes, Group Ⅱ required 331.1 minutes, Group Ⅲ rquired 499.4 minutes, and Group Ⅳ rquired 1328.0 minutes. 4. The ratio of time for adequate nursing care and direct care time in the Internal Medicine and Goneral Surgery units was 67.4%-83.4% and 94.7%-99.3% in the Intensie Care Unit. 5. Average daily direct care time per patient was 5.5 hours in the Internal Medicine unit and 11.5 hours in the Intensive Care Unit. 6. Time spent in indirect care was 48.3 minutes for computer recording,34.8 minutes for giving and receiving patient information for shift duty, 28.0 minutes for eating and resting time, 26.6 minutes for transfering and identifying patients, 25.6 minutes for identifying Doctor's order, 23.9 minutes for recording vital signs. 7. Time spent in indirect care was 282.2 minutes by head nurses (charge nurses), 258.7 minutes by nurses and 261.6 minutes by nurse aids. 8. The average nurse's workload was 9.3 hours and daily indirect nursing time required 46.3%-50. 5% of above mentioned workload time. .9. The average daily indirect care time per patient was expected to be 57.7 minutes in the Internal Medicine unit and 3.3 hours in the Intensive Care Unit.

  • PDF

표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구 (Comparison of shearbond strength between metal and indirect resin according to the different conditionings)

  • 최수영;최현민;문홍석;심준성;박영범;이근우
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.264-271
    • /
    • 2017
  • 목적: 본 연구에서는 4종의 간접복합레진에 대하여 금합금과 Ni-Cr합금에 대한 결합강도의 차이와 각각의 합금에 표면형태를 다르게 하여 일정한 온도의 증류수에 보관 전과 후에 전단결합강도의 차이가 있는지 알아보고자 하였다. 재료 및 방법: 금속 시편을 주조 제작하였는데, 금합금과 Ni-Cr합금의 표면형태를 flatting, bead, loop로 하여 4종의 간접복합레진(Gradia, Tescera Sinfony and in;joy)당 60개씩 총 240개를 준비하였다. 이후 금속표면에 각각의 제조사에서 지시한대로 간접 복합레진을 접착하였다. 간접복합레진의 중합 24시간 후에 만능시험기를 이용하여 전용 지그에 금속시편을 부착 후, 전단결합강도를 측정하였다. 또한 증류수에 240시간 보관 후에 같은 방법으로 전단결합강도를 측정하였다. 결과: 금속의 표면 형태에 따른 전단결합강도 측정에서 4종의 레진 모두 bead군에서 높은 결합강도를 보였고 loop, flatting 순이었다 (P < .05). 수조에서 240시간 보관 후에는 Gradia가 모든 군에서 다른 레진 군에 비해 비슷하거나, 통계적으로 유의하게 높은 (P < .05) 전단결합강도를 나타내었다. 결론: 금속표면의 형태에 따라, 금속의 종류에 따라, 물속 보관 전후에 따라 금속과 간접복합레진의 결합력의 차이를 나타내었고 추가 실험을 통해 최적의 조합에 따른 임상에서의 적용가능성을 보여주었다.