• Title/Summary/Keyword: indicator microorganisms

Search Result 82, Processing Time 0.027 seconds

Indicator Microorganisms Used as Fecal Contamination in Aquatic Environments (수계환경에서 분변성 오염의 지표로 사용되는 미생물들)

  • 이건형
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.3
    • /
    • pp.189-196
    • /
    • 2002
  • The direct detection of intestinal pathogens and viruses often requires costly, tedious, and time-consuming procedures. These requirements developed a test to show that the water was contaminated with sewage-borne pathogens by assessing the hygienic quality of water based on indicator microorganisms whose presence indicates that pathogenic microorganisms may also be present. Various groups of microorganisms have been suggested and used as indicator microorganisms. Proposed and commonly used microbial indicators are total coliforms, fecal coliforms, fecal streptococci, Clostridium perfringens, heterotrophic plate count, bacteriophage, and so on. Unfortunately, most, if not all, of these indicators are not ideal because of the sensitivity and resistance to environment stresses and disinfection. However, the development of gene probes and PCR technology may give hope for the discovery of rapid and simple methods toy detecting small number of fecal pathogens in various environments.

Discharge Characteristics of the Indicator Microorganisms of Combined Sewer Overflows (합류식 하수관거 월류수의 지표미생물 배출 특성)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.627-635
    • /
    • 2006
  • Combined sewer overflow (CSOs) is a primary diffuse source degrading water quality of urban streams. In this study, CSOs caused by 5 different rainfall events at an urban watershed located in Daejeon city were monitored for the indicator microorganism concentrations. Event mean concentration (EMC) of the indicator microorganisms were: total coliform = $2.46{\times}10^6CFU/100mL$; fecal coliform = $1.01{\times}10^6CFU/100mL$; E.coli = $5.20{\times}10^5CFU/100mL$; and Fecal Streptococci = $6.08{\times}10^5CFU/100mL$. In addition, coliform concentrations were well correlated with suspended solid concentrations and the first flush effects were identified. Settling tests were carried out to estimate removal rate of indicator organisms by sedimentation from CSOs. As microorganisms are discharged in association with suspended solid, ten minutes of settlement can lower 44% of indicator microorganism leading.

Indicator microorganisms concentrations change after irrigation of wastewater treatment effluent in paddy field for water reuse (용수 재이용을 위한 하수처리수 관개 후 논에서의 지표성 미생물의 거동)

  • Jung, Kwang-Wook;Yoon, Chun-G.
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.583-586
    • /
    • 2003
  • The objective of this research was to examine the significance of change to indicator microorganisms (TC, FC, and E. coli) in the paddy field and repair of UV disinfected secondary effluent. Average concentrations of Microorganisms were maintained by more than about 1,000 MPN/100mL in paddy field after irrigation. Microorganism repair was evaluated in relation to UV dose in photoreactivating light and dark. In addition, a significant inverse relationship was found between UV dose and repair of indicator microorganisms when the research of wastewater was conducted in the condition of low and high UV dose.

  • PDF

Mortality Rates of Pathogen Indicator Microorganisms Discharged from Point and Non-point Sources in Urban Area (도시지역 점원, 비점원에서 유출되는 병원균 지표미생물의 사멸률)

  • Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1075-1081
    • /
    • 2006
  • In this research, mortality rates of pathogen indicator microorganisms discharged from various point sources and diffuse sources in urban area were measured. Water samples were taken at domestic sewer, combined sewer overflow, effluent from a wastewater treatment plant, urban river, and sediment of an urban river. Mortality rates of indicator microorganisms in domestic sewer estimated by assuming the first order kinetics at $20^{\circ}C$ were as follows: total coliform = 0.092/day, fecal coliform = 0.185/day, E. coli = 0.252/day, and fecal streptococci = 0.281/day. Sensitivity of mortality rates of total coliform on temperature was estimated as $K_{temp}=K_{20}{\times}1.162^{(temp-20)}$ for the range of $10-20^{\circ}C$. Mortality rates due to sunlight were measured as 1.22-1.59/day while mortality rate due to settling for 40 min were estimated as $9.21{\times}10^3-20.0{\times}10^3/day$.

Investigation of Indicator Microorganism Concentrations after Reclaimed Water Irrigation in Paddy Rice Pots (재처리수 관개후 지표미생물의 농도변화 조사)

  • Jung Kwang-Wook;Yoon Chun-Gyeong;Jang Jae-Ho;Kim Hyung-Chul;Jeon Ji-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.4
    • /
    • pp.75-85
    • /
    • 2005
  • A study was performed to examine the effects of reclaimed-water irrigation on microorganism con-centration in ponded-water of paddy rice plots. Several treatments were used and each one was triplicated to evaluate the change of indicator microorganisms (total coliforms (TC), fecal coliforms FC), and E. coli) concentrations in 2003 and 2004 growing seasons. Their concentrations increased significantly right after irrigation, but decreased about $45\%$ in 24 hours. It implies that agricultural activities such as plowing and fertilizing should be practiced one or two days after irrigation considering health-risks. Treatments with UV-disinfected water irrigation demonstrated significantly lower concentrations than others including control plots where natural surface water was irrigated. The monitoring results from actual paddy rice fields and experimental paddy plots showed that concentrations of indicator microorganisms ranged from $10^2\;to\;10^5$ MPN/100mL. A comprehensive assessment of existing agricultural practices and a thorough monitoring in the field as well as treatment-plots are recommended to make more realistic national guidelines more applicable. UV-disinfected water irrigation reduced microorganism concentrations in paddy fields down to below the concentration of conventional paddy rice culture, and is thought to be an effective and feasible measure fur agricultural reuse of secondary effluent.

Analysis of Pathogenic Microorganism's Contamination on Organic Leafy Vegetables at Greenhouse in Korea (유기농 시설엽채류의 유해미생물 오염평가)

  • Oh, Soh-Young;Nam, Ki-Woong;Yoon, Deok-Hoon
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • This study was conducted to evaluate the microbiological safety of leafy vegetables (perilla leaf and lettuce) in relation to cultivation methods. A total of 2,304 samples were collected from plants, harvesting tools and soil mulching film during the production and harvest stages from organic- and conventional- farms. From the samples, sanitary indicator microorganisms (total aerobic bacteria, coliforms, E. coli., Environmental Listeria, and yeast and mold) and pathogenic microorganisms (S. aureus, B. cereus, Salmonella spp., Clostridium spp., and L. monocytogenes) were analyzed. In the production stage of leafy vegetables, the sanitary indicator microorganisms was not detected regardless of cultivation method or it was detected to be less than $3.4\;Log\;CFU/100cm^2$. B. cereus and S. aureus were found to be 0.22~1.55 Log CFU/g in perilla leaf and lettuce produced by organic farms, and S. aureus was not detected and B. cereus was found to be 0.42~2.19 Log CFU/g in conventional farms. There were no significant differences between two cultivation methods. In the harvesting tools and soil mulching film, the contamination levels of sanitary indicator microorganisms and pathogenic microorganisms was low regardless of the cultivation method. However, there was a positive correlation ($R^2=0.4526$) in that the higher the microbial contamination level in the harvesting tool, the higher the microbial contamination on the surface of the plant. In addition, sanitary indicator microorganisms and pathogenic microorganisms were not detected or low in soil mulching during the production of organic leafy vegetables. As a result of this study, microbial hygiene control by soil mulching and harvesting tools was more important than difference of cultivation method in production of leafy vegetables.

Assessment of the ozonation against pathogenic bacteria in the effluent of the quarantine station

  • Park, Seon Yeong;Kim, Joo Han;Kim, Chang Gyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.13 no.1
    • /
    • pp.10-19
    • /
    • 2021
  • This study investigated how ozone treatment can successfully inactivate pathogenic bacteria in both artificial seawater and effluents discharged from the fishery quarantine station in Pyeongtaek Port, Korea. Vibrio sp. and Streptococcus sp. were initially inoculated into the artificial seawater. All microbes were almost completely inactivated within 10 min and 30 min by injecting 6.4 mg/min and 2.0 mg/min of ozone, respectively. It was discovered that the water storing Pleuronichthys, Pelteobagrus, and Cyprinus imported from China contained the indicator bacteria, Vibrio sp., Enterococcus sp., total coliforms, and heterotrophic microorganisms. Compared to the control, three indicator bacteria were detected at two to six times higher concentrations. The water samples displayed a diverse microbial community, comprising the following four phyla: Bacteroidetes, Proteobacteria, Firmicutes, and Actinobacteria. Almost all indicator bacteria were inactivated in 5 min at 2.0 mg/min of ozonation; comparatively, 92.9%-98.2% of the less heterotrophic microorganisms were deactivated within the same time period. By increasing the dosage to 6.4 mg/min, 100% deactivation was achieved after 10 min. Despite the almost complete inactivation of most indicator bacteria at high doses after 10 min, several bacterial strains belonging to the Proteobacteria have still been found to be resistant under the given operational conditions.

Evaluation of Influent Water Quality Using Indicator Microorganisms in Lake Shiwha (지표미생물을 이용한 시화호 유입수의 수질평가)

  • Lee, Hee-Tae;Kim, Hee-Yeon;Park, Hyun-Jin;Cho, Young-Eun;Ryu, So-Young;Lee, Kyung-Jin;Jung, Jong-Sun;Ko, Gwang-Pyo
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.86-94
    • /
    • 2008
  • Lake Shiwha, an artificial lake located near metropolitan Seoul, offers a unique water environment and has been suspected to have high levels of chemical and microbiological contaminations. Lake Shiwha was originally connected to the sea but currently has four major surface water inputs from agricultural, municipal, industrial areas and in addition an occasional inflow from the sea. The objectives of this study are to investigate the relative contribution of microbial contaminants from each of the inflowing surface waters and to identify appropriate microbial indicator organisms in this unique water environment. We measured the levels of microbial contaminations in the four inflowing surface waters. A number of microbial indicator organisms including total coliform (TC), fecal coliform (FC), E. coli, Enterococci, somatic and male-specific coliphages were analyzed. Bacterial indicator microorganisms were detected and quantified by the $Colilert^{(R)},\;Enterolert^{(R)}$ kit. Surface water (50 l) was sampled by $ViroCap^{TM}\;5"$ cartridge filters and analyzed by the single agar layer method for detecting coliphages. The concentrations of TC, FC, E. coli, and Enterococci were 1543 CFU/100 ml${\sim}1.99{\times}10^6$ CFU/100 ml, 0 CFU/100 ml${\sim}202$ CFU/100ml, 0 CFU/100 ml${\sim}1.80{\sim}10^5$ CFU/100ml, 74 CFU/100 ml${\sim}3408$ CFU/100 ml, respectively. The male-specific and somatic coliphages were detected in three different inflowing surface waters. Isolated E. coli and Enterococci strains were further analyzed by 16s rDNA amplification and subsequent phylogenetic analysis from Jungwang-chun, Ansan-chun, Banwol-chun and penstock of inflowing surface water. Our results indicated that the concentrations of different fecal indicator microorganisms might not be highly correlated with each other. Multiple microbial indicator organisms should be used for monitoring microbial contamination and microbial source tracking methods.

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

A Study of Antimicrobial Resistance in Escherichia coli and the Distribution of Indicator Microorganisms in Asan City (아산시 지표미생물의 분포와 Escherichia coli의 항생제 내성에 관한 연구)

  • Lee, Geun-Yeol;Kim, Keun-Ha;Kwon, Mun-Ju;Kwon, Hyuk-Ku;Kim, Yeon-Hee;Lee, Jang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Efforts to evaluate water pollution using indicator microorganisms have been underway for decades, and driven by research on water purity control applications, water quality criteria are growing more and more strict. Furthermore, recent reports indicate that high concentrations of antibiotics are not absorbed, and are present in excrement from animals and humans dosed with unnecessarily high levels of antibiotics. This has emerged as very important issue from the standpoint of being an ecological and health hazard. In this study, water pollution was analyzed through physicochemical and microbiological means, and antibiotic resistance in indicator microorganisms was assessed. In physicochemical analysis, biochemical oxygen demand (BOD)$_5$ and chemical oxygen demand (COD)$_{Mn}$ evaluation showed that pollution by organisms was highest at the G1 location with a high human population, and the DP location which has many livestock-containing households. The indicator organism levels at the G1 location were: Total Coliforms (1205 colony forming units (CFU)/100 ml), Fecal Coliforms (270 CFU/100 ml), Escherichia coli (253 CFU/100 ml) and Fecal Streptococci (210 CFU/100 ml), while for the DP location levels were: Total Coliforms (1480 CFU/100 ml), Fecal Coliforms (438 CFU/100 ml), E. coli (560 CFU/100 ml), and Fecal Streptococci (348 CFU/100 ml). Levels of fecal indicator microorganisms such as Fecal Coliforms, E. coli and Fecal Streptococci were high at all locations in the fall (the period after the rainy season), and the yearly distribution was similar between these organisms. If the number of livestock-containing households was high, almost all strains of E. coli (as distinct from the other indicator organisms) showed resistance to antibiotics, with the degree of resistance varying between areas. E. coli strains from the OY area in particular, which has a high population density, showed strong resistance to AM10 and Va30. While strong antibiotic resistance was observed overall at the DP and OY locations, no resistance was observed at the EB location.