• Title/Summary/Keyword: index of agreement (d)

Search Result 71, Processing Time 0.035 seconds

Comparison of Calibrations using Modified SWAT Auto-calibration Tool with Various Efficiency Criteria (다양한 검증 지수를 이용한 SWAT 자동 보정 비교 평가)

  • Kang, Hyun-Woo;Ryu, Ji-Chul;Kim, Nam-Won;Kim, Seong-Joon;Engel, Bernard A.;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.19-19
    • /
    • 2011
  • The appraisals of hydrology model behavior for flow and water quality are generally performed through comparison of simulated data with observed ones. To perform appraisal of hydrology model, some criteria are often used, such as coefficient of determination ($R^2$), Nash and Sutcliffe model efficiency coefficient (NSE), index of agreement (d), modified forms of NSE and d, and relative efficiency criteria NSE and d. These criteria are used not only for hydrology model estimations also for various comparisons of two data sets; This NSE has been often used for SWAT calibration. However, it has been known that the NSE value has some limitations in evaluating hydrology at watersheds under monsoon climate because this statistic is largely affected by higher values in the data set. To overcome these limitations, the SWAT auto-calibration module was enhanced with K-means clustering and direct runoff/baseflow modules. However the NSE is still being used in this module to evaluate model performance. Therefore, the SWAT Auto-calibration module was modified to incorporate alternative efficiency criteria into the SWAT K-means/direct runoff-baseflow auto-calibration module. It is expected that this enhanced SWAT auto-calibration module will provide better calibration capability of SWAT model for all flow regime.

  • PDF

Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System (사이버나이프 실시간 종양추적 시스템을 이용한 방사선수술 시 주요 장기의 선량분포 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Lee, Sang-Hoon;Choi, Jin-Ho;Lee, Re-Na;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.

  • PDF

Comparison of Statistic Methods for Evaluating Crop Model Performance (작물모형 평가를 위한 통계적 방법들에 대한 비교)

  • Kim, Junhwan;Lee, Chung-Kuen;Shon, Jiyoung;Choi, Kyung-Jin;Yoon, Younghwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.4
    • /
    • pp.269-276
    • /
    • 2012
  • The objective of this short communication is to introduce several evaluation methods to crop model users because the evaluation of crop model performance is an important step to develop or select crop model. In this paper, mean error, mean absolute error, index of agreement, root mean square error, efficiency of model, accuracy factor and bias factor were explained and compared in terms of dimension and observed number. Efficiency of model and index of agreement are dimensionless and independent of number of observation. Relative root mean square, accuracy factor and bias factor are dimensionless and not independent of number of observation. Mean error and mean absolute error are affected by dimension and number of observation.

Anaysis and design of inhomogeneous optical filters using tapered transmission line theory (테이퍼 전송선 원리를 이용한 불균일 굴절률 광여파기의 해석 및 설계)

  • 권영재;장호성;임성규;오명환
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.36-42
    • /
    • 1997
  • Optical filters with graded index profiles are designed by applying the fourier transform to a riccati equation which governs the reflection and transmission characteristics of inhomogeneous refractive index distributions. The inhomogeneous refractive index profile of an optical filter with specified target spectrum is obtained through iterations. The spectra response of the inhomogeneous refractive index layers are analyzed by using runge-dutta numerical method to solve the differential euations of the amplitude and the phase of reflection coefficient derived from the riccati equation and the results are in good agreement with the resutls obtained by using matrix method.

  • PDF

PAGAN II: THE EVOLUTION OF AGN JETS ON SUB-PARSEC SCALES

  • OH, JUNGHWAN;TRIPPE, SASCHA;KANG, SINCHEOL;KIM, JAE-YOUNG;PARK, JONG-HO;LEE, TAESEOK;KIM, DAEWON;KINO, MOTOKI;LEE, SANG-SUNG;SOHN, BONG WON
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.299-311
    • /
    • 2015
  • We report first results from KVN and VERA Array (KaVA) VLBI observations obtained in the frame of our Plasma-physics of Active Galactic Nuclei (PAGaN) project. We observed eight selected AGN at 22 and 43 GHz in single polarization (LCP) between March 2014 and April 2015. Each source was observed for 6 to 8 hours per observing run to maximize the uv coverage. We obtained a total of 15 deep high-resolution images permitting the identification of individual circular Gaussian jet components and three spectral index maps of BL Lac, 3C 111 and 3C 345 from simultaneous dual-frequency observations. The spectral index maps show trends in agreement with general expectations – flat core and steep jets – while the actual value of the spectral index for jets shows indications for a dependence on AGN type. We analyzed the kinematics of jet components of BL Lac and 3C 111, detecting superluminal proper motions with maximum apparent speeds of about 5c. This constrains the lower limits of the intrinsic component velocities to ~ 0.98c and the upper limits of the angle between jet and line of sight to ~20°. In agreement with global jet expansion, jet components show systematically larger diameters d at larger core distances r, following the global relation d ≈ 0.2r, albeit within substantial scatter.

Clinical Feasibility of Dual-Layer CT With Virtual Monochromatic Image for Preoperative Staging in Patients With Breast Cancer: A Comparison With Breast MRI

  • Bokdong Yeo;Kyung Min Shin;Byunggeon Park;Hye Jung Kim;Won Hwa Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.9
    • /
    • pp.798-806
    • /
    • 2024
  • Objective: Dual-layer CT (DLCT) can create virtual monochromatic images (VMIs) at various monochromatic X-ray energies, particularly at low keV levels, with high contrast-to-noise ratio. The purpose of this study was to assess the clinical feasibility of contrast-enhanced chest DLCT with a low keV VMI for preoperative breast cancer staging, in comparison to breast MRI. Materials and Methods: A total of 152 patients with 155 index breast cancers were enrolled in the study. VMIs were generated from contrast-enhanced chest DLCT at 40 keV and maximum intensity projection (MIP) with three-dimensional (3D) reconstruction was performed for both bilateral breast areas. Two radiologists reviewed in consensus the 3D MIP images of the chest DLCT with VMI and breast MRI in separate sessions with a 3-month wash-out period. The detection rate and mean tumor size of the index cancer were compared between the chest DLCT with VMI and breast MRI. Additionally, the agreement of tumor size measurement between the two imaging modalities were evaluated. Results: Of all index cancers, 84.5% (131/155) were detected in the chest DLCT with VMI, while 88.4% (137/155) were detected in the breast MRI (P = 0.210). The Bland-Altman agreement between the chest DLCT with VMI and breast MRI was a mean difference of -0.05 cm with 95% limits of agreement of -1.29 to 1.19 cm. The tumor size in the chest DLCT with VMI (2.3 ± 1.7 cm) was not significantly different from that in the breast MRI (2.4 ± 1.6 cm) (P = 0.106). Conclusion: The feasibility of chest DLCT with VMI was demonstrated for preoperative tumor staging in breast cancer patients, showing comparable cancer detectability and good agreement in tumor size measurement compared to breast MRI. This suggests that chest DLCT with VMI can serve as a potential alternative for patients who have contraindications to breast MRI.

A Comparison of Fasting Glucose and HbA1c for the Diagnosis of Diabetes Mellitus Among Korean Adults (공복혈당과 당화혈색소에 의한 당뇨병 진단 비교)

  • Yun, Woo-Jun;Shin, Min-Ho;Kweon, Sun-Seong;Park, Kyeong-Soo;Lee, Young-Hoon;Nam, Hae-Sung;Jeong, Seul-Ki;Yun, Yong-Woon;Choi, Jin-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.5
    • /
    • pp.451-454
    • /
    • 2010
  • Objectives: The American Diabetes Association (ADA) has recently recommended the HbA1c assay as one of four options for making the diagnosis of diabetes mellitus, with a cut-point of $\geq$ 6.5%. We compared the HbA1c assay and the fasting plasma glucose level for making the diagnosis of diabetes among Korean adults. Methods: We analyzed 8710 adults (age 45-74 years), who were not diagnosed as having diabetes mellitus, from the Namwon study population. A fasting plasma glucose level of $\geq$126 mg/dL and an A1c of $\geq$ 6.5% were used for the diagnosis of diabetes. The kappa index of agreement was calculated to measure the agreement between the diagnosis based on the fasting plasma glucose level and the HbA1c. Results: The kappa index of agreement between the fasting plasma glucose level and HbA1c was 0.50. Conclusions: The agreement between the fasting plasma glucose and HbA1c for the diagnosis of diabetes was moderate for Korean adults.

Sound Reduction Index of Interior Door by Aperture Sizes at Door's Bottom (하부틈새 크기에 따른 도어의 음향감쇠계수 분석)

  • Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.834-840
    • /
    • 2010
  • The Sound reduction indices(SRIs) of interior door with 13 different size apertures are measured in acoustic chamber. Also, as a theoretical approach, the SRIs are estimated using Gomperts' theory. In this study, the aperture of interior door is focused on the lower part of door leaf which is well known as a main cause to deteriorate the sound insulation performance of door. The results show that the SRI of door strongly depends on the aperture width and the dip in the measured sound reduction index curve by the resonance effect within aperture is observed at high-frequency. On the whole, the values calculated by theory are in good agreement with the measured values including the position of resonance dip. The average difference between the measured and the calculated values is 0.9 dB for 13 doors with different size aperture in terms of the weighted SRI.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

Compressibility behaviour of peat reinforced with precast stabilized peat columns and FEM analysis

  • Kalantari, Behzad;Rezazade, Reza K.
    • Geomechanics and Engineering
    • /
    • v.9 no.4
    • /
    • pp.415-426
    • /
    • 2015
  • Researches have been done to discover ways to strengthen peat soil deposits. In this model study, fibrous peat that is the most compressible types of peat has been reinforced with precast peat columns stabilized with ordinary Portland cement and polypropylene fibres. Rowe cell consolidation tests as well as plate load tests (PLTs) were conducted on various types of test samples to evaluate the strength and deformation of untreated peat and peat reinforced by various types of columns. PLTs were conducted in a specially designed and fabricated circular steel test tank. The compression index ($C_c$) and recompression index ($C_r$) of fibrous peat samples reduced considerably upon use of precast columns. Also, PLT results confirmed the results obtained from Rowe cell tests. Use of polypropylene fibres added to cement further decreased ($C_c$) and ($C_r$) and increased load bearing capacity of untreated peat. Finite element method (FEM) using Plaxis 3D was carried out to evaluate the stress distributions along various types of tested samples and also, to compare the deformations obtained from FEM analysis with the actual maximum deformations found from PLTs. FEM results indicate that most of the induced stresses are taken on the upper portion of tested samples and reach their maximum values below the loading plate. Also, a close agreement was found between actual deformation values obtained from PLTs and values resulted from FEM analysis for various types of tested samples.