• Title/Summary/Keyword: incorrect measurement

Search Result 78, Processing Time 0.023 seconds

Variation of Dose due to the Wound Electrode of Ionization Chamber (굴곡이 있는 전리함 집전극에 기인한 선량 변화)

  • Lee, Byung-Koo;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.203-209
    • /
    • 2008
  • Nowadays the risk of radiation is getting more serious, so we must know the exact dose that was irradiated, Because very high radiation dose is used in radiation therapy field. We used the ionization chamber which measure the radiation dose in this study. We tried to know the incorrect result from the distortion of geometric structure of ionization chamber and we studied how to find the distortion of geometric structure of ionization chamber. We used a radio fluoroscopy to find the wound degree of electrode of ionization chamber and a reconstructed 3D CT image to analyze the wound degree of electrode quantitatively. we measured degree of distortion by comparing with absorbed dose of normal electrode and wound electrode. The comparative result is not absolute dosimetry at specific point but relative dosimetry between thats. We measured 4 MV, 10MV photon with same absorbed dose and dose rate. The degree of distortion of wound electrode was totally $5.5{\sim}7.2%$, and there was no difference between two energies. The variation induced from radiation dose to be irradiated and dose rate, and the degree of distortion from wound direction also was almost similar value. We could find that the geometric structure of ionization chamber that can influence a basic measurement of radiation dose can be changed by old usage and inattention of management in this study, especially winding of electrode can be happened, in radiation therapy field, It is very important to keep precise radiation dose quantitatively.

The Evaluation of Application to MODIS LAI (Leaf Area Index) Product (MODIS LAI (엽면적지수) Product의 활용성 평가)

  • Ha, Rim;Shin, Hyung-Jin;Park, Geun-Ae;Hong, Woo-Yong;Kim, Seong-Jun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.61-72
    • /
    • 2008
  • Leaf area index (LAI) is a key biophysical variable influencing land surface processes such as photosynthesis, transpiration and energy balance, and is a required input to estimate evapotranspiration in various ecological and hydrological models. The development of more correct and useful LAIs estimation techniques is required by these importance, but LAIs had been assumed in most LAI research through simple relations with the normalized difference vegetation index (NDVI) because the field measurement is difficult on wide area. This paper is to evaluate the MODIS LAI Product's practical use by comparing with LAIs that is derived from NOAA AVHRR NDVIs and the 2 years (2003-2004) measured LAIs of Korea Forest Research Institute in Gyeongancheon watershed (561.12 $Km^2$). As a result, the MODIS LAIs of deciduous forests showed higher values about 14 % and 15~30 % than the measured LAIs and NOAA LAIs. In the year of 2003, the MODIS LAIs in coniferous forests were 5 % higher than the measured LAIs, and showed about 7 % differences comparing with the NOAA LAIs except April. These differences come from the insufficient field data measured in partial points of the target area, and the extracted reference data from MODIS LAIs include the limits of spatial resolution and the error of incorrect land cover classification. Thus, using the MODIS data by the proper correction with the measured data can be useful as an input data for ecological and hydrological models which offers the vegetation information and simulates the water balance of a given watershed.

  • PDF

Effective PPG Signal Processing Method for Detecting Emotional Stimulus (감성 자극 판단을 위한 효과적인 PPG 신호 처리 방법)

  • Oh, Dong-Gi;Min, Byung-Seok;Kwon, Sung-Oh;Kim, Hyun-Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.393-402
    • /
    • 2012
  • In this study, we propose a signal processing algorithm to measure the arousal level of a human subject using a PPG(Photoplethysmography) sensor. From the measured PPG signals, the arousal level is determined by PPI(Pulse to Pulse Interval) and discrete-time signal processing. We ran psychophysical experiments displaying visual stimuli on TV display while measuring PPG signal from a finger, where the nature landscape scenes were used for restorative effect, and the urban environments were used to stimulate the stress. However, the measured PPG signals may include noise due to subject movement and measurement error, which results in incorrect detections. In this paper, to mitigate the noise impact on stimulus detection, we propose a detecting algorithm using digital signal processing methods and statistics of measured signals. A filter is adopted to remove a high frequency noise and adaptively designed taking into account the statistics of the measured PPG signals. Moreover we employ a hysteresis method to reduce the distortion of PPI in decision of emotional. Via experiment, we show that the proposed scheme reduces signal noise and improves stimulus detection.

Comparison of Feature Point Extraction Algorithms Using Unmanned Aerial Vehicle RGB Reference Orthophoto (무인항공기 RGB 기준 정사영상을 이용한 특징점 추출 알고리즘 비교)

  • Lee, Kirim;Seong, Jihoon;Jung, Sejung;Shin, Hyeongil;Kim, Dohoon;Lee, Wonhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.263-270
    • /
    • 2024
  • As unmanned aerial vehicles(UAVs) and sensors have been developed in a variety of ways, it has become possible to update information on the ground faster than existing aerial photography or remote sensing. However, acquisition and input of ground control points(GCPs) UAV photogrammetry takes a lot of time, and geometric distortion occurs if measurement and input of GCPs are incorrect. In this study, RGB-based orthophotos were generated to reduce GCPs measurment and input time, and comparison and evaluation were performed by applying feature point algorithms to target orthophotos from various sensors. Four feature point extraction algorithms were applied to the two study sites, and as a result, speeded up robust features(SURF) was the best in terms of the ratio of matching pairs to feature points. When compared overall, the accelerated-KAZE(AKAZE) method extracted the most feature points and matching pairs, and the binary robust invariant scalable keypoints(BRISK) method extracted the fewest feature points and matching pairs. Through these results, it was confirmed that the AKAZE method is superior when performing geometric correction of the objective orthophoto for each sensor.

A Suvey on Satisfaction Measurement of Automatic Milking System in Domestic Dairy Farm (자동착유시스템 설치농가의 설치 후 만족도에 관한 실태조사)

  • Ki, Kwang-Seok;Kim, Jong-Hyeong;Jeong, Young-Hun;Kim, Yun-Ho;Park, Sung-Jai;Kim, Sang-Bum;Lee, Wang-Shik;Lee, Hyun-June;Cho, Won-Mo;Baek, Kwang-Soo;Kim, Hyeon-Shup;Kwon, Eung-Gi;Kim, Wan-Young;Jeo, Joon-Mo
    • Journal of Animal Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present survey was conducted to provide basic information on automatic milking system (AMS) in relation to purchase motive, milk yield and quality, customer satisfaction, difficulties of operation and customer suggestions, etc. Purchase motives of AMS were insufficient labor (44%), planning of dairy experience farm (25%), better performance of high yield cows (19%) and others (6%), respectively. Average cow performance after using AMS was 30.9l/d for milk yield, 3.9% for milk fat, 9,100/ml for bacterial counts. Sixty-eight percentage of respondents were very positive in response to AMS use for their successors but 18% were negative. The AMS operators were owner (44%), successor (44%), wife (6%) and company worker (6%), respectively. The most difficulty (31%) in using AMS was operating the system and complicated program manual. The rate of response to system error and breakdown was 25%. The reasons for culling cow after using AMS were mastitis (28%), reproduction failure (19%), incorrect teat placement (12%), metabolic disease (7%) and others (14%), respectively. Fifty-six percentages of the respondents made AMS maintenance contract and 44% did not. Average annual cost of the maintenance contract was 6,580,000 won. Average score for AMS satisfaction measurement (1 to 5 range) was 3.2 with decrease of labor cost 3.7, company A/S 3.6, increase of milk yield 3.2 and decrease of somatic cell count 2.8, respectively. Suggestions for the higher efficiency in using AMS were selecting cows with correct udder shape and teat placement, proper environment, capital and land, and attitude for continuous observation. Systematic consulting was highly required for AMS companies followed by low cost for AMS setup and systematization of A/S.

Blood Pressure Cuff Bladders Tailored For Koreans (한국인 맞춤형 혈압계 커프 블래더)

  • Hwang, Lark Hoon;Park, Woo Sung;Na, Seung Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.822-829
    • /
    • 2013
  • Hypertension is one of the most common clinical diseases, with an increasing prevalence globally. Hypertension triggers various harmful consequences and affects multiple organs. Life-long care may be required in some cases. According to the Korea Center for Disease Control and Prevention, the prevalence of hypertension is gradually increasing. A 2011 survey revealed that 28.9% of Korean adults had hypertension. The prevalence rates were slightly higher among men than women. Accurate measurement of blood pressure(BP) is crucial to classify patients, to identify BP-related risks, and to inform correct treatment. For accurate blood pressure measurement, the use of a cuff bladder size appropriate for the mid-upper arm circumference(MUAC) is essential. Incorrect sized cuff bladder is one of the main causes of equipment error affecting sphygmomanometer accuracy. When commercial sphygmomanometers were examined, the cuff bladders differed from the dimensions specified in the ISO 81060-1:2007 standards. Undercuffing is responsible for a spurious overestimation of BP in patients with large arms leading to overdiagnosis of hypertension, whereas overcuffing (that is, use of relatively large cuffs with small arms), may be responsible for an opposite problem, leading to erroneous underestimation of BP levels. The cuff bladder sizes recommended by the American Heart Association(AHA) are an arm circumference(AC) of 17-25 cm for small-sized adults, AC of 24-32 cm for adults, AC of 32-42 cm for normal-sized adults, and AC of 42-50 cm for obese adults. In contrast, the AC of Korean adults ranges from 23-31 cm, belonging to a single type of adult bladder. Three types of bladders are necessary for Korean adults with an AC of 23-31cm. Hospitals often use one or two differently-sized Western cuffs for adult patients, which can yield inaccurate BP determinations. Cuff bladders with dimensions based on anthropometric reference data obtained from Koreans will aid hospitals to measure BP more accurately.

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

A Proposal to Control System and the Problems of the Problems of the Report about Supply and Demand for Medical Technicians and Management Policy ("의료기사인력수급에 관한 보고서"의 문제점과 관리제도의 개선방안)

  • Kim, Sang-Hyun;Lim, Yongmoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.25-30
    • /
    • 2008
  • Purpose: In this paper, we have analyzed the problems of the Oh's report which is used to the basic data for supply and demand of medical technicians and studied a proposal for improvement to control system and supply and demand of korean optometrists. Methods: We have analyzed errors of Oh's report including supply and demand for medical technicians and management policy, expecting number for future optician, inaccurate estimation by limited data (employment rate, retirement rate, mortality rate) and an incorrect method of measurement for future supply and demand. Results: Oh's report showed the 18% error for estimation of supply which exclude the irregular entrance students. The estimation of supply was calculated by graduation rate 62.6% (college and University of Technology are 78.9% and 85.98% respectively), employment rate 65.8% (the average employment between 2002 and 2007 is 73.96%) and retirement rate is 2.3% (the retirement of pharmacists is 1.3%) but it showed the significant differences to objective data. For estimate the suitable ratio of optometrists to the population, the ratio use of medical facilities by an age group was used, and suggested spectacle wearers 1,280 persons (populations 2,928 persons) per optometrist but the different from reference of Germany (4,706 persons), America (1,789 persons) and Korea (1,825 persons/an optometrist) are applied to estimation on supply. This report applied the low employment rate and argued that maintain the present situation, but claimed that utilize unemployment persons. The above result has induced double weighting effect on estimation of supply. Conclusions: To solve the related problems of supply and demand, we have to make a search for exact data and optimum application model, have to take an example of nation similar job category as Germany and the research result of the job satisfaction into consideration. After we get the integrated research result, we must carried out the policy with fairness and balance for the estimation of supply and demand. Therefore exact research is required prior to beginning policy establishment, government and related group have to make a clear long-term plan and permanent organization for medical technician to establish supply and demand of medical technician.

  • PDF