• Title/Summary/Keyword: incorrect measurement

Search Result 78, Processing Time 0.019 seconds

Comparison of Sound Pressure for Detecting Incorrect Sonar Measurements (잘못된 초음파 센서 데이터를 여과하기 위한 음압 비교법)

  • Lee, Kyoung-Min;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2009
  • In this paper, we address the problem of detecting incorrect sonar measurements. We use ideas from the inconsistency of information among sonar measurements together with the sound pressure of the wave from the sonar sensor to develop a new method, called the comparison of the sound pressure (CSP), to detect incorrect sonar readings. The inconsistency of information in cells can be a clue that indicates candidates for incorrect measurements, and the sound pressure of the wave from the sonar sensor determines incorrect readings among the candidates. From various experiments, the proposed method is confirmed that it is better than existing method at deciding the state of sonar measurements.

The Design and Implementation of the Position Calibration System Using Sensor on u-WBAN (u-WBAN 기반의 센서를 이용한 자세교정 시스템 설계 및 구현)

  • Moon, Seung-Jin;Park, Yoon-Sung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.2
    • /
    • pp.304-310
    • /
    • 2010
  • Chronic pain and herniated disk is a common disease that 80% of adults are experienced. There diseases rates of caused by the physical shock, such as the traffic accident, and the accidental fall is about 10%. And the most of these diseases is caused by having habitual incorrect position. People know that incorrect position would cause to accumulate continuous stress, but it is not easy to correct position. Because it does not recognize incorrect position repeated habitual consequently. This system collects data of user position after sensors that could measure position attach on use and presumes correct position used by position presumption algorithms. Its system purpose is continuing incorrect position could be aware to user and lead to change to correct position to prevent habituation of incorrect position. If habitual of correct position continues through accurate measurement and repeating cognitive learning, it would help for children and chronic patience.

Development of Postural Correction App Service with Body Transformation and Sitting Pressure Measurement (체위 변환과 좌압 측정을 통한 자세교정 앱 서비스의 개발)

  • Jung-Hyeon Choi;Jun-Ho Park;Young-Ki Sung;Jae-Yong Seo;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.1
    • /
    • pp.15-20
    • /
    • 2023
  • In general, maintaining an incorrect sitting posture for a long time is widely known to adversely affect the spine. Recently, several researchers have been interested in the causal relationship between incorrect sitting posture and spinal diseases, and have been studying methods to precisely measure changes in sitting or standing posture to prevent spinal diseases. In previous studies, we have developed a sensor device capable of measuring real-time posture change, applied a momentum calculation algorithm to improve the accuracy of real-time posture change measurement, and verified the accuracy of the postural change measurement sensor. In this study, we developed a posture measurement and analysis device that considers changes in the center of body pressure through the developed sitting pressure measurement, and it confirmed the sensor as an auxiliary tool to increase the accuracy of posture correction training with improving the user's visual feedback.

An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy (신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구)

  • JEONG, SOON YOUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

An Experimental Study on the Performance of Cooling Tower Unit for Mechanical Draft (기계통풍식 냉각탑 유닛의 성능에 관한 실험적 연구)

  • JEONG, SOON YOUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.6
    • /
    • pp.642-648
    • /
    • 2021
  • In this paper, an experimental study was conducted on the performance of the cooling tower. In order to improve reliability in the cooling tower performance test, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. Therefore, the measurement result of the performance experiment is not an actual value, but a reasonable estimated value. The measurement uncertainty for the test was calculated and the measured results were presented.

An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source (공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구)

  • SOON YOUNG JEONG
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

Measurement of Water Flow in Closed Conduits by Chemical Tracer Method (추적자를 이용한 유량 측정)

  • Lee, Sun-Ki;Chung, Bag-Soon;Kim, Chang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.19-26
    • /
    • 1999
  • Thermal output in a nuclear power plant is verified with calorimetric heat balance on the secondary plant. The calorimetry involves the precise measurement of the feedwater flow rate. However, the correct indication of feedwater flow rate obtained by a pressure-difference measurement across a venturi can be affected by instrument errors, fouling or a poorly developed velocity profile. This can result in an inaccurate mass flow rate and consequently an inaccurate estimate of power. The purpose of this study is to develop verification methods with accuracy better than $0.5\%$ for high precision flow measurement to be used for measuring feedwater flow rate. This chemical tracer method is a testing process that uses tracers which can be applied to quantify losses in electrical output due to the incorrect measurements of feedwater flow rate. And this system has good response to the variation of the flow rate. Accuracy of better than 0.5 percent can be expected for feedwater flow measurement, providing that the system can be stabilized during the test. This methodology is applicable to other flow systems well.

  • PDF

A Study on the Physical Measurement Method for the Development of Bicycle Fitting Integrated System

  • Shon, Gyoung-Hoan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.123-133
    • /
    • 2019
  • Bicycle fitting used to depend on empirical adherence of bicycle Peter and intuitive judgment by hand, but recent developments in industry and the Fourth Industrial Revolution have continuously developed other related tools that can be applied to bicycle fitting. Depending on these circumstances, bicycle fitting technology is also developing, and due to the difficulty of the technicians, there is a limit to popularizing. The Bicycle Integrated Fitting System has the need for this study to make these problems easy for anyone to operate by the system of manual. The purpose of this study is to examine the methods of physical sizing among the various stages of developing these systems. Accurate physical measurements can improve the efficiency of bicycle riding and minimize the injury of bicycle risers issued by incorrect fittings. Thus, in this study, physical measurement methods for bicycle fitting were derived by body region and applied to the post-measurement fitting as well as the location and method of measurement. It has prepared a basis for establishing a core database for physical measurement of development of integrated bicycle fitting system. Research was conducted to enhance understanding and utilization of users after system development and results were derived for the purpose of the study. Research was conducted to establish a database for the development of a bicycle integrated fitting system, and future research on bicycle fitting methods, application of the system, and hardware development should be carried out.

Calculation of Hopper Dredging Capacity by Combination of DGPS and Echo Sounder (DGPS/EchoSounder 조합에 의한 호퍼준설량 산정)

  • 이종출;이용희;김종원;강윤성
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.77-82
    • /
    • 2004
  • This study deals with the estimation of dredged soil-quantity using DGPS&Echo-Sounder method. In measurement of topography, surveyors have been surveying the depth with rod and sounding lead. This method, however, is not effective because of long time and a lot of human power, in addition it is incorrect. This paper has studied on the solution of those problems using DGPS&Echo-sounder data to calculate the dredged soil-quantity. This paper says the effective and economical methods using DGPS&Echo-Sounder data there.

  • PDF

Smart Pressure Transducer with Cu-Ni Thin Film Strain Gages (지능형 박막 스트레인 게이지 압력 변환기)

  • Park, Chan-Won;Lee, Seong-Jae;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1564-1567
    • /
    • 1998
  • This paper presents a smart thin film pressure transducer which is highly suitable for a precise and remote measurement of pressure and has the following smart functions: automatic zero tracking, automatic span adjustment, temperature compensation, continuous self-diagnostics for faults(open strain gages, abnormal data, incorrect A/D conversion, and overpressure), data memory and multi-drop communication with PC.

  • PDF