• 제목/요약/키워드: incorrect measurement

검색결과 78건 처리시간 0.018초

잘못된 초음파 센서 데이터를 여과하기 위한 음압 비교법 (Comparison of Sound Pressure for Detecting Incorrect Sonar Measurements)

  • 이경민;정완균
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.273-279
    • /
    • 2009
  • In this paper, we address the problem of detecting incorrect sonar measurements. We use ideas from the inconsistency of information among sonar measurements together with the sound pressure of the wave from the sonar sensor to develop a new method, called the comparison of the sound pressure (CSP), to detect incorrect sonar readings. The inconsistency of information in cells can be a clue that indicates candidates for incorrect measurements, and the sound pressure of the wave from the sonar sensor determines incorrect readings among the candidates. From various experiments, the proposed method is confirmed that it is better than existing method at deciding the state of sonar measurements.

u-WBAN 기반의 센서를 이용한 자세교정 시스템 설계 및 구현 (The Design and Implementation of the Position Calibration System Using Sensor on u-WBAN)

  • 문승진;박윤성
    • 한국지능시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.304-310
    • /
    • 2010
  • 현대를 살아가는 현대인들이 경험하는 만성통증 및 디스크는 성인의 80% 이상이 경험하는 흔한 질병이다. 이러한 질환들 중 교통사고, 추락 등 물리적인 충격에 의한 발생율은 10%정도이며 대부분이 습관적으로 부적합한 자세를 취하게 되어 특정 부위에 지속적인 스트레스가 쌓여 발생하게 된다. 이처럼 부적합한 자세가 오랫동안 이어져 질환의 원인이 되는 것을 알면서도 고쳐지지 않는 이유는 지속적인 반복을 통한 습관화로 인하여 부적합한 자세를 바로 인지하지 못함으로써 바르게 교정하지 못하고 지속되어지기 때문이다. 따라서 본 시스템은 자세를 측정할 수 있는 센서들을 사용자에게 부착 후 사용자의 자세에 따른 데이터를 수집하여 정확한 자세를 측정하고 자세추정알고리즘을 이용하여 해당 자세의 적합여부를 추정한다. 사용자가 부적합한 자세를 지속적으로 취할 경우 이를 인지할 수 있도록 한다. 그리고 적합한 자세로 변경하도록 유도하여 부적합한 자세의 습관화를 방지하는데 목적을 두고 있다. 또한 부적합한 자세의 원인을 분석 후 제거하여 적합한 자세를 취하는데 보조자의 기능을 수행 한다. 정확한 측정을 통한 반복적인 인지 학습을 통해 올바른 자세를 습관화 한다면 성장기 어린이와 만성 질환자에게 많은 도움을 줄 것으로 생각 된다.

체위 변환과 좌압 측정을 통한 자세교정 앱 서비스의 개발 (Development of Postural Correction App Service with Body Transformation and Sitting Pressure Measurement)

  • 최정현;박준호;성영기;서재용;박준모
    • 융합신호처리학회논문지
    • /
    • 제24권1호
    • /
    • pp.15-20
    • /
    • 2023
  • 일반적으로 잘못된 앉은 자세를 장시간 유지하는 것은 척추에 나쁜 영향을 미치는 것으로 널리 알려져 있다. 최근 여러 연구자들이 잘못된 앉은 자세와 척추질환의 인과관계에 관심을 두고 있으며, 척추질환 예방을 위해 앉거나 서는 자세의 변화를 정밀하게 측정할 수 있는 방법을 연구해왔다. 우리는 과거 연구에서 실시간 체위 변환 측정이 가능한 센서 디바이스를 개발하고 운동량 계산 알고리즘을 적용하여 실시간 자세 전환 측정 정확도를 향상시켰으며, 체위 변환 측정 센서의 정확도를 검증하였다. 본 연구에서는 좌압 측정을 통해 체중심의 변화를 고려한 자세 측정 및 분석 장치를 개발하였으며, 개발된 센서는 사용자의 시각적 피드백을 개선하여 자세 교정 훈련 정확도를 높이는 보조 도구로의 활용 가능성을 확인하였다.

신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

기계통풍식 냉각탑 유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cooling Tower Unit for Mechanical Draft)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.642-648
    • /
    • 2021
  • In this paper, an experimental study was conducted on the performance of the cooling tower. In order to improve reliability in the cooling tower performance test, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. Therefore, the measurement result of the performance experiment is not an actual value, but a reasonable estimated value. The measurement uncertainty for the test was calculated and the measured results were presented.

공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구 (An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

추적자를 이용한 유량 측정 (Measurement of Water Flow in Closed Conduits by Chemical Tracer Method)

  • 이선기;정백순;김창호
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Thermal output in a nuclear power plant is verified with calorimetric heat balance on the secondary plant. The calorimetry involves the precise measurement of the feedwater flow rate. However, the correct indication of feedwater flow rate obtained by a pressure-difference measurement across a venturi can be affected by instrument errors, fouling or a poorly developed velocity profile. This can result in an inaccurate mass flow rate and consequently an inaccurate estimate of power. The purpose of this study is to develop verification methods with accuracy better than $0.5\%$ for high precision flow measurement to be used for measuring feedwater flow rate. This chemical tracer method is a testing process that uses tracers which can be applied to quantify losses in electrical output due to the incorrect measurements of feedwater flow rate. And this system has good response to the variation of the flow rate. Accuracy of better than 0.5 percent can be expected for feedwater flow measurement, providing that the system can be stabilized during the test. This methodology is applicable to other flow systems well.

  • PDF

A Study on the Physical Measurement Method for the Development of Bicycle Fitting Integrated System

  • Shon, Gyoung-Hoan
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권3호
    • /
    • pp.123-133
    • /
    • 2019
  • Bicycle fitting used to depend on empirical adherence of bicycle Peter and intuitive judgment by hand, but recent developments in industry and the Fourth Industrial Revolution have continuously developed other related tools that can be applied to bicycle fitting. Depending on these circumstances, bicycle fitting technology is also developing, and due to the difficulty of the technicians, there is a limit to popularizing. The Bicycle Integrated Fitting System has the need for this study to make these problems easy for anyone to operate by the system of manual. The purpose of this study is to examine the methods of physical sizing among the various stages of developing these systems. Accurate physical measurements can improve the efficiency of bicycle riding and minimize the injury of bicycle risers issued by incorrect fittings. Thus, in this study, physical measurement methods for bicycle fitting were derived by body region and applied to the post-measurement fitting as well as the location and method of measurement. It has prepared a basis for establishing a core database for physical measurement of development of integrated bicycle fitting system. Research was conducted to enhance understanding and utilization of users after system development and results were derived for the purpose of the study. Research was conducted to establish a database for the development of a bicycle integrated fitting system, and future research on bicycle fitting methods, application of the system, and hardware development should be carried out.

DGPS/EchoSounder 조합에 의한 호퍼준설량 산정 (Calculation of Hopper Dredging Capacity by Combination of DGPS and Echo Sounder)

  • 이종출;이용희;김종원;강윤성
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.77-82
    • /
    • 2004
  • This study deals with the estimation of dredged soil-quantity using DGPS&Echo-Sounder method. In measurement of topography, surveyors have been surveying the depth with rod and sounding lead. This method, however, is not effective because of long time and a lot of human power, in addition it is incorrect. This paper has studied on the solution of those problems using DGPS&Echo-sounder data to calculate the dredged soil-quantity. This paper says the effective and economical methods using DGPS&Echo-Sounder data there.

  • PDF

지능형 박막 스트레인 게이지 압력 변환기 (Smart Pressure Transducer with Cu-Ni Thin Film Strain Gages)

  • 박찬원;이성재;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1564-1567
    • /
    • 1998
  • This paper presents a smart thin film pressure transducer which is highly suitable for a precise and remote measurement of pressure and has the following smart functions: automatic zero tracking, automatic span adjustment, temperature compensation, continuous self-diagnostics for faults(open strain gages, abnormal data, incorrect A/D conversion, and overpressure), data memory and multi-drop communication with PC.

  • PDF