• 제목/요약/키워드: inclined channel

검색결과 84건 처리시간 0.026초

거친 채널에서 거친 벽면의 수가 압력강하와 열전달에 미치는 효과 (Effect of Number of Rough Walls on Pressure Drop and Heat Transfer in Roughened Channel)

  • 김명호;배성택;안수환;강호근;김창동;우준석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1083-1090
    • /
    • 2005
  • Repeated ribs are used on heat exchange surfaces to promote turbulence and enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concern detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue is tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall have a 45$^{\circ}$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increase with increasing the number of rough walls.

  • PDF

일정 열유속을 가진 사각채널에서 거친 벽면의 수가 열전달에 미치는 효과 (Effect of Number of Rough Walls on Heat Transfer in the Square Channel with a Uniform Heat Flux)

  • 배성택;김명호;이대희;안수환
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.30-35
    • /
    • 2005
  • Repeated ribs are used on heat exchanger surfaces to promote turbulence and to enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concerns detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue was tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall had a $45^{\circ}$ inclined square rib. Uniform heat flux was maintained on the whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increased with increasing the number of rough walls.

  • PDF

사각채널에서 거친 벽면의 수가 압력강하와 열전달에 미치는 효과 (Effect of Number of Rough Walls on Pressure Drop and Heat Transfer in Square Channel)

  • 배성택;김명호;진용수;김성태;안수환
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.340-348
    • /
    • 2005
  • Repeated ribs are used on heat exchange surfaces to promote turbulence and enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concern detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue is tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall have a $45{\circ}C$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increase with increasing the number of rough walls.

Analysis of Stem Wave due to Long Breakwaters at the Entrance Channel

  • Kwon, Seong-Min;Moon, Seung-Hyo;Lee, Sang-Heon;Yoo, Jae-Woong;Lee, Joong-Woo
    • 한국항해항만학회지
    • /
    • 제41권5호
    • /
    • pp.345-352
    • /
    • 2017
  • Recently, a new port reserves deep water depth for safe navigation and mooring, following the trend of larger ship building. Larger port facilities include long and huge breakwaters, and mainly adopt vertical type considering low construction cost. A vertical breakwater creates stem waves combining inclined incident waves and reflected waves, and this causes maneuvering difficulty to the passing vessels, and erosion of shoreline with additional damages to berthing facilities. Thus, in this study, the researchers have investigated the response of stem waves at the vertical breakwater near the entrance channel and applied numerical models, which are commonly used for the analysis of wave response at the harbor design. The basic equation composing models here adopted both the linear parabolic approximation adding the nonlinear dispersion relationship and nonlinear parabolic approximation adding a linear dispersion relationship. To analyze the applicability of both models, the research compared the numerical results with the existing hydraulic model results. The gap of serial breakwaters and aligned angles caused more complicated stem wave generation and secondary stem wave was found through the breakwater gap. Those analyzed results should be applied to ship handling simulation studies at the approaching channels, along with the mooring test.

현생 및 고기 급경사 선상지-삼각쭈계 퇴적층의 특성과 퇴적상 (Depositional features and sedimentary facies of steep-faced fan-delta systems: modern and ancient)

  • 최문영;조성권;황인걸
    • 한국석유지질학회지
    • /
    • 제2권2호
    • /
    • pp.71-81
    • /
    • 1994
  • 선상지 삼각주는 흔히 깊은 분지로 전진하여 급경사의 전면층을 형성한다. 현생의 급경사 선상지-삼각주는 사태흔적, 츄트/협곡, 스웨일(swale), 로브(lobe), 스플레이(splay). 및 암설낙하(debris fall) 등의 표층 지형에 의해 특징지워진다. 이들은 강하구에서 발생하는 퇴적물 붕괴나 중력류에 의해 생성된다. 고기의 선상지-삼각주 퇴적상은 경사가 급한 전면층과 비교적 경사가 완만한 기저층 및 전삼각주(prodelta)층을 구성한다. 이는 다시 판상 또는 쐐기 모양의 역암 및 사암, 사태 충진층, 츄트/협곡 충진층, 판상층, 열편층, 사태층 등으로 구성된다.

  • PDF

AHP 기법에 의한 농업용 저수지의 상태평가 기준 설정 (Establishment of Condition Assessment Criteria in Agricultural Reservoirs by AHP)

  • 심재웅;이영학;이달원
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.17-26
    • /
    • 2022
  • In this study, in order to establish the criteria for evaluation of importance by the type of facility specialized for agricultural reservoirs, an expert group consisting of a total of 167 members who were in management, or specialized in the fields of design, research, and diagnosis were organized, and the importance for facilities was set with application of the AHP technique. The importance of dam body, spillway, and intake structure composing a reservoir were set at 59%, 24%, and 17%, and the importance of dam crest, upstream slope, and downstream slope constituting a dam body was set at 32%, 31%, and 37%, respectively. In addition, the importance of approach channel, regulated channel, chute channel, and stilling basin consisting a spillway was set at 15%, 44%, 26%, and 15%, and the importance of inclined conduit and outlet conduit consisting an intake structure was set at 35% and 65%, respectively. The safety grade of the reservoirs evaluated by applying the newly presented importance values in this study showed the rearrangement of the grades with a change of 11% compared to the previous grades. In this way, the newly established criteria are expected to be utilized as basic data with strategic importance in reservoir safety management and disaster prevention as well as the operation of systems in the future.

사각 덕트 내에 설치된 2개의 경사진 배플에 의한 열전달 증진 효과에 관한 실험 수치해석 (Experimental and Numerical Analysis for Effects of Two Inclined Baffles on Heat Transfer Augmentation in a Rectangular Duct)

  • 강호근;안수환
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.751-760
    • /
    • 2007
  • Baffles enhance heat transfer by disturbing boundary layer and bulk flow, creating impingement, and increasing heat transfer surface area. This study was performed to determine how the two inclined baffles (${\alpha}=5^{\circ}$ perforated models) placed at a rectangular channel affect heat transfer and associated friction characteristics. The parametric effects of perforated baffles (3, 6 and 12 holes) and flow Reynolds number ranging from 28,900 to 61,800 on the heated target surface are explored. Comparisons of the experimental data with the numerical results by commercial code CFX 10.0 are presented. As for the investigation of heat transfer behaviors on local Nusselt number with two baffles placed at $x/D_h=0.8$ and $x/D_h=8.0$ of the edge of baffles, it is evident that the inclined perforated baffles augment overall heat transfer significantly by both jet impingement and boundary layer separation. There exists an optimum perforation density to maximize heat transfer coefficients; i.e., the average Nusselt number increases with increasing number of holes, but the friction factor decreases with an increase in the hole number placed at baffles.

AN OPTIMUM DESIGN STUDY OF INTERLACING NOZZLE BY ANALYZING FLUID FLOW INSIDE INTERLACING NOZZLES

  • Juraeva Makhsuda;Ryu Kyung Jin;Kim Sang Dug;Song Dong Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.93-97
    • /
    • 2005
  • Air interlacing serves to protect the yarn against damage, strengthens inter-filament compactness or cohesion, and ensures fabric consistency. The air interlacing nozzle is used to introduce intermittent nips to a filament yarn so as to improve its performance in textile processing. This study investigates the effect of interlacing nozzle geometry on the interlacing process. The geometries of interlacing nozzles with multiple air inlets located across the width of a yarn channels are investigated. The basic interlacing nozzle is the yarn channel, with a perpendicular single air inlet in the middle. The yarn channel shapes are cross sections with semicircular or rectangular shapes. This paper presents three doubled sub air inlets with main air inlet and one of them is slightly inclined doubled sub air inlets with main air inlet. The compressed air coming out from the inlet hits the opposing wall of the yarn channel, divides into two branches, flows trough the top side of yarn channel, joins with the compressed air coming out from the sub air inlet and then creates two free jets at both ends of the yarn channel. The compressed air moves in the shape of two opposing directional vortices. The CFD-FASTRAN was used to perform steady simulations of impinging jet flow inside of the interlace nozzles. The vortical structure and the flow pattern such as pressure contour, particle traces, velocity vector plots inside of interlace nozzle geometry are discussed in this paper.

  • PDF

사각채널에서 설치된 배플에 의한 열전달 거동에 관한 실험 및 수치해석 (Experimental and Numerical Investigation for the Effect of Baffles on Heat Transfer Behaviors in a Rectangular Channel)

  • 강호근;안수환;배성택
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.45-46
    • /
    • 2006
  • Experimental and numerical analysis on the heat transfer behaviors and the associated frictional loss in a rectangular channel with two inclined perforated baffles($\;5^{\circ}$) mounted on the bottom plate has been systematically performed. The parametric effects of perforated baffles (3, 6, 9 holes) and flow Reynolds number on heat transfer characteristics of the heated target surface are explored. A combination of two baffles of same overall size was considered and the flow Reynolds number for this study is varied between 28,900 and 61,800. Comparisons of the experimental data with the numerical results by commercial code CFX 5.7 are made. As for the investigation of heat transfer behaviors on local Nusselt number with the two baffles installed at $x/D_h=0.8\;and\;x/D_h=8.0$, it is evident that there exist an optimum perforation density to maximize heat transfer coefficients; i.e., the maximum Nusselt number decreases with increasing number of holes.

  • PDF

직교하는 단락형 리브를 부착한 판형 열교환기 관내측 열유동 해석 (The Thermal and Flow Analysis in the Channel of Plate Heat Exchanger with Crossed-Discrete Ribs)

  • 이관수;문형규;정길완
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.678-686
    • /
    • 1999
  • The purpose of this work is to Investigate the pressure drop and the heat transfer characteristics in the channel of plate heat exchanger with crossed-discrete ribs. The flow is assumed to be three-dimensional, laminar and periodically fully developed. Computations have been carried out for angles of attack from $0^{\circ}$ to $90^{\circ}$ and ratios of rib height from 0.15 to 0.46 for various values of Reynolds and Prandtl numbers. The heat transfer was improved by inclined ribs generating helical vortices and secondary flows. The results show that the pressure drop has a maximum value at $70^{\circ}$ and the heat transfer has a maximum value at $45^{\circ}$. As the rib height increases, the pressure drop and the heat transfer increase quadratically, and the increasing rate of pressure drop is higher than that of the heat transfer. As Reynolds number increases, the pressure drop increases in proportion to the square of Reynolds number and the heat transfer increases linearly.