• 제목/요약/키워드: incineration system

검색결과 143건 처리시간 0.024초

사업장폐기물의 순산소 소각기술 (Polymer Waste Incineration by Oxygen Enriched Combustion)

  • 한인호;최광호;정진우
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.132-139
    • /
    • 2000
  • Oxygen enriched incineration can increase the incineration capacity for wastes and dramatically reduce air pollutant emissions such as CO and dioxine by the allowing complete combustion of wastes in incinerator. Furthermore, this technology is proven to have many benefits including an energy-saving, cost-effective, and versatile application for diverse wastes compared with the conventional air incineration technology. The reduced pollutant emissions in flue gas and higher incineration efficiency are also available when the oxygen enriched air is used for the high temperature incineration systems. On the basis of the experimental results the oxygen enrichment system is successfully applied to the rotary kiln incinerator for industrial wastes. The oxygen enriched incineration system could be allowed more compact design of incinerator and flue gas treatment system due to both increasing incineration capacity and reducing flue gas volume. Therefore, oxygen enriched incineration technology is becoming highlighted in the waste incinerator which strongly require more stable efficiency and environmentally friendly and safe operationPut Abstract text here.

  • PDF

폐열회수시설이 설비된 생활폐기물 소각자원화시설 온실가스 배출량 산정 시 오차분석 (2009~2013) (Study on the Measurement of GHG Emissions and Error Analysis in Form the MSW Incineration Plant Equipment with the Recovery Heat System (2009~2013))

  • 최원근;서란숙;박승철
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.239-246
    • /
    • 2016
  • This study aims to analyze region-specific trends in changing greenhouse gas emissions in incineration plants of local government where waste heat generated during incineration are reused for the recent five years (2009 to 2013). The greenhouse gas generated from the incineration plants is largely $CO_2$ with a small amount of $CH_4$ and $N_2O$. Most of the incineration plants operated by local government produce steam with waste heat generated from incineration to produce electricity or reuse it for hot water/heating and resident convenience. And steam in some industrial complexes is supplied to companies who require it for obtaining resources for local government or incineration plants. All incineration plants, research targets of this study, are using LNG or diesel fuel as auxiliary fuel for incinerating wastes and some of the facilities are using LFG(Landfill Gas). The calculation of greenhouse gas generated during waste incineration was according to the Local Government's Greenhouse Emissions Calculation Guideline. As a result of calculation, the total amount of greenhouse gas released from all incineration plants for five years was about $3,174,000tCO_2eq$. To look at it by year, the biggest amount was about $877,000tCO_2eq$ in 2013. To look at it by region, Gyeonggido showed the biggest amount (about $163,000tCO_2eq$ annually) and the greenhouse gas emissions per capita was the highest in Ulsan Metropolitan City(about $154kCO_2eq$ annually). As a result of greenhouse gas emissions calculation, some incineration plants showed more emissions by heat recovery than by incineration, which rather reduced the total amount of greenhouse gas emissions. For more accurate calculation of greenhouse gas emissions in the future, input data management system needs to be improved.

전과정평가를 이용한 폐리튬이온전지의 소각에 대한 장/단기 환경영향 평가 (Life Cycle Assessments of Long-term and Short-term Environmental Impacts for the Incineration of Spent Li-ion Batteries (LIBs))

  • 정수정;이지용;손정수;허탁
    • 공업화학
    • /
    • 제17권2호
    • /
    • pp.163-169
    • /
    • 2006
  • 현재 한국의 폐LIBs 소각시스템에 대한 환경적인 측면들을 규명하고, 개선시키기 위해서 전과정평가를 수행하였다. 본 연구에서는 기존의 대부분 연구에서는 생략이 되었던 소각재의 매립과 관련된 환경영향도 평가되었다. 전기 생산과정과 소각공정으로부터 배출되는 $CO_{2}$와 소각공정에서 대기와 수계로 배출되는 중금속에 의한 환경영향이 전체 환경영향의 약 90%를 차지하였다. 특히, 중금속의 배출에 의한 환경영향이 압도적인데, 이를 개선시키기 위해서는 폐LIBs 와 같이 중금속의 함량이 높은 폐기물은 일반폐기물과 분리하여 소각하는 것이 필요하다. 반면에 소각 후에 발생되는 소각재에 의한 환경영향은 미미하였다. 이는 소각재가 소각과정을 거치면서 이미 안정한 산화물을 형성한 것에 기인한다.

반복제어법을 이용한 소각장 NOx 저감용 SCR 시스템의 제어 (Control of SCR System for NOx Reduction in a Refuse Incineration Plant Using Repetitive Control Method)

  • 김인규;여태경;김환성;김상봉
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2762-2770
    • /
    • 2000
  • The refuse incineration plant has an important role in saving the combustion energy for local heating system. But harmful combustion gas(NOx etc.) leads to some serious environmental problem. To reduce the gas, a SCR(Selective Catalytic Reduction)system is installed and it is controlled by adjusting the flow of ammonia gas(NH3) . In this paper, we apply a repetitive control method to reduce NOx by adjusting the flow of ammonia gas for SCR system in a refuse incineration plant which is located in Haeundae, Pusan, Firstly, we analyze the inlet NOx period by FFt method, and verify its periodic variations. Secondly, we design a repetitive control system by using state space model method. Lastly, the effectiveness of repetitive control system is shown by comparing to a conventional PID control in simulation and experimental results.

Research Investigations at the Municipal (2×35) and Clinical (2×5 MW) Waste Incinerators in Sheffield, UK

  • Swithenbank, J.;Nasserzadeh, V.;Ewan, B.C.R.;Delay, I.;Lawrence, D.;Jones, B.
    • 청정기술
    • /
    • 제2권2호
    • /
    • pp.100-125
    • /
    • 1996
  • After recycle of spent materials has been optimised, there remains a proportion of waste which must be dealt with in the most environmentally friendly manner available. For materials such as municipal waste, clinical waste, toxic waste and special wastes such as tyres, incineration is often the most appropriate technology. The study of incineration must take a process system approach covering the following aspects: ${\bullet}$ Collection and blending of waste, ${\bullet}$ The two stage combustion process, ${\bullet}$ Quenching, scrubbing and polishing of the flue gases, ${\bullet}$ Dispersion of the flue gases and disposal of any solid or liquid effluent. The design of furnaces for the burning of a bed of material is being hampered by lack of an accurate mathematical model of the process and some semi-empirical correlations have to be used at present. The prediction of the incinerator gas phase flow is in a more advanced stage of development using computational fluid dynamics (CFD) analysis, although further validation data is still required. Unfortunately, it is not possible to scale down many aspects of waste incineration and tests on full scale incinerators are essencial. Thanks to a close relationship between SUWIC and Sheffield Heat&Power Ltd., an extended research programme has been carried out ar the Bernard Road Incinerator plant in Sheffield. This plant consists of two Municipal(35 MW) and two Clinical (5MW) Waste Incinerators which provide district heating for a large part of city. The heat is distributed as hot water to commercial, domestic ( >5000 dwelling) and industrial buildings through 30km of 14" pipes plus a smaller pipe distribution system. To improve the economics, a 6 MW generator is now being added to the system.

  • PDF

Life cycle impact assessment of the environmental infrastructures in operation phase: Case of an industrial waste incineration plant

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Environmental Engineering Research
    • /
    • 제22권3호
    • /
    • pp.266-276
    • /
    • 2017
  • A life cycle impact assessment was applied in an industrial waste incineration plant to evaluate the direct and indirect environmental impacts based on toxicity and non-toxicity categories. The detailed life cycle inventory of material and energy inputs and emission outputs was compiled based on the realistic data collected from a local industrial waste incineration plant, and the Korean life cycle inventory and ecoinvent database. The functional unit was the treatment of 1 tonne of industrial waste by incineration and the system boundary included the incineration plant and landfilling of ash. The result on the variation of the impact by the unit processes showed that the direct impact was decreased by 79.3, 71.6, and 90.1% for the processes in a semi dry reactor, bag filter, and wet scrubber, respectively. Considering the final impact produced from stack, the toxicity categories comprised 91.7% of the total impact. Among the toxicity impact categories, the impact in the eco-toxicity category was most significant. A separate estimation of the impact due to direct and indirect emissions showed that the direct impact was 97.7% of the total impact. The steam recovered from the waste heat of the incineration plant resulted in a negative environmental burden.

국내 주요 쓰레기 소각시설로부터 발생하는 수은의 대기 배출량에 관한 연구 (Release of Airborne Mercury from Major Waste Incineration Systems in Korea)

  • 김기현;송동웅
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.593-596
    • /
    • 1996
  • The encironmental consequences of airborne mercury (Hg) release from waste incineration system are wellperceived. To provide some insights into those phenomena, we have assessed annual emission rates of Hg for several major incineration systems in Korea following the procedures developed abroad. The results of our computation, derived on the basis of dividing the whole amounts of annually incinerated wastes into municipal solid Wastes (MSW), and medical solid wastes (MDW), indicate that the extent of Hg release may be significant nationwide, possibly approaching a few tonnes of Hg per year basis. Knowing that the airborne transport and the resulting deposition of Hg can exert serious pollutions to the aquatic ecosystems, of particular fisheries, we are obliged to establish a stringent measure to confine the amount of Hg released via incineration.

  • PDF

화학공장 소각공정에 대한 안전기술기준 제안 (Proposal of the Safety Technical Standards for Incineration Process in the Chemical Plants)

  • 마병철;권혁면;김영철
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.64-69
    • /
    • 2012
  • The purpose of this study is to suggest new safety technical standards to improve the safety in the incineration process. Firstly, we analyzed the major accidents occurred in the incineration process since 1996 and proposed 4 articles which is required to be added newly to the existing KOSHA GUIDE. Secondly, we also performed the HAZOP study for each study node and also suggested 3 articles. Finally, we analyzed recommendations commented for PSM reports which have been submitted from the enterprise located in Honam province since 2005 and proposed 2 articles as well. We understand that all 9 articles proposed above, should be added to the KOSHA GUIDE in order to improve the safety in the incineration process and to prevent the major fire and explosion accidents in the design stage.

Development of a Fuzzy Knowledge-Based System for the Control of a Refuse Incineration Plant -Application of Advanced Fuzzy Techniques for a Complex Multivariable Control Problem

  • B.Krause;C.von-Altrock;Lim, K.per;Dr.W.Sch-fers
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1109-1113
    • /
    • 1993
  • A refuse incineration plant is a complex process, whose multi-variable control problems can not be solved conventionally by deriving an exact mathematical model of the process. The usage of advanced fuzzy technologies within the suitable development methodology is demonstrated by a controller implemented for the refuse incineration plant in Hamburg-Stapelfeld, Germany.

  • PDF

쓰레기 소각 플랜트의 모델규명 (Model Identification of Refuse Incineration Plants)

  • 황이철;김진환
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.34-41
    • /
    • 1999
  • This paper identifies a linear combustion model of Refuse Incineration Plant(RIP) which characterizes its combustion dynamics, where the proposed model has thirteen-inputs and one-output. The structure of the RIP model is given as an ARX model which obtained from the theoretical analysis. And then, some unknown model parameters are decided from experimental input-output data sets, using system identification algorithm based on Instrumental Variables(IV) method. In result, it is shown that the proposed model well approximates the input-output combustion characteristics riven by experimental data sets.

  • PDF