• Title/Summary/Keyword: incineration

Search Result 577, Processing Time 0.03 seconds

Mechanical Characteristics of Municipal Waste Incineration Bottom Ashes (생활폐기물 소각 바닥재의 역학적 특성)

  • Oh, Myounghak;Lee, Jeonghyeop;Park, Haeyong;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.11
    • /
    • pp.21-27
    • /
    • 2015
  • Due to the population growth and development of industry, waste from household and industries has increased. As the advanced countries experienced these problems, they have already started research on recycling methods of waste incineration ashes. Domestic recycling rate of incineration ash became up to 80 percent as high as the level of developed countries, but the recycling was limited to fly ash for admixture in concrete. In case of bottom ash, most of bottom ash was reclaimed in the landfills. Therefore, basic physical property and mechanical experiments for bottom ash were conducted in this study to evaluate the possibility of incineration bottom ash as an alternative construction materials. Bottom ashes from three different landfills with two different incineration methods were tested. Incineration methods are Stoker type Incinerator and Pyrolysis-Melting Treatment. Bottom ash can be used as an alternative granular material for construction based on the basic physical property and mechanical characteristics similar to those of sandy materials. However, the incineration method should be considered since it can affect the material and mechanical characteristics of the incineration bottom ash.

Environmental impact evaluation and improvement measure of incineration plant by life cycle assessment (전과정평가를 이용한 소각시설의 환경영향평가 및 개선방안)

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.88-100
    • /
    • 2013
  • This study evaluated the direct and indirect environmental impacts of various unit operations of a industrial waste incineration plant by using the life cycle assessment tool and reviewed the improvement plan. During the incineration process, the direct environmental impact was decreased with decrease in emission of various air pollutants by incorporating an air pollution prevention facilities. However, an increase in indirect environmental impacts was observed as a consequence of resources and energy of consumption at the various operational facilities. Consequently, quantitative direct and indirect impact were 89.1%, 10.9%, respectively. The environmental impact analysis of system revealed the highest impact of incineration followed by the impacts of other unit processes such as semidry reactor, and bag-filter. The various air pollutants and ashes generated during the incineration process caused the most significant environmental impact. Among the various categories of environmental impact, global warming accounted the highest impact(more than 85%) followed by eutrophication, and abiotic depletion. As a result of the avoided impact by the utilization of heat generated during the waste incineration process, using an incineration heat for steam and electricity obtained the impact reduction of 45.5%, 19.8%. So, during siting of new incineration plant, the utilization of steam generated from the waste combustion is highly considered to reduce the environmental impact.

Study on Co-incineration of Municipal Solid Waste and Organic Sludges (도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구)

  • Jurng, Jong-Soo;Chin, Sung-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

Nanowaste Treatment via Incineration (나노폐기물의 소각 처리)

  • Kim, Younghun
    • Clean Technology
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Rapid growth in nanotechnology promise novel benefits through the exploitation of their unique industrial applications. However, as increasing of production amount of nanomaterials, their unintentional exposure to the environment has been caused. Therefore, there is a need for effective management of nanowaste to the sustainable nanotechnology. One possible endpoint at the environmental exposure scenario for nanowaste treatment is incineration. Although a few study on the incineration of nanomaterials was reported, pioneering researchers found that although it is possible to incinerate nanowaste without releasing nanoparticles into the atmosphere, the residues (bottom ash or slag) with nanomaterials eventually end up in landfills. Though there are still many questions to understand the fate of nanomaterials in incinerator, firstly we have to study whether nanowaste treatment via incineration is safe to human and environment.

A Study of Assessment Method for Site Feasibility of Municipal Solid Waste Incineration (생활폐기물소각장의 입지타당성 평가기법)

  • Lee, Mu-Choon
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.2
    • /
    • pp.123-135
    • /
    • 1997
  • The solid waste incineration facilities which cause environmental pollution. And those are some kind of loathing facilities for residents who do not want it. This problem could be solved by location feasibility study. The purpose of location feasibility study was to determine one site out of three candidate sites. This study which was done by the law, environmental and economic factor was considered for optimum site selection. Comparative evaluation among the candidate sites was done by ordinal scale and thus the optimum site was selected.

  • PDF

Algorithms for effective combustion control of refuse incineration plant (쓰레기 소각로의 효율적인 연소제어를 위한 퍼지예측제어 알고리즘)

  • 박종진;강신준;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.20-23
    • /
    • 1997
  • Refuse incineration plant operations involve many kinds of uncertain factors, such as the variable physical properties of refuse as fuel and the complexity of the burning phenomenon. That makes it very difficult to apply conventional control methods to the combustion control of the refuse. In this paper, an adaptive fuzzy model predictive controller is proposed for the combustion control of the refuse. And computer simulation was carried out to evaluate performance of the proposed controller.

  • PDF

Development of a Fuzzy Knowledge-Based System for the Control of a Refuse Incineration Plant -Application of Advanced Fuzzy Techniques for a Complex Multivariable Control Problem

  • B.Krause;C.von-Altrock;Lim, K.per;Dr.W.Sch-fers
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1109-1113
    • /
    • 1993
  • A refuse incineration plant is a complex process, whose multi-variable control problems can not be solved conventionally by deriving an exact mathematical model of the process. The usage of advanced fuzzy technologies within the suitable development methodology is demonstrated by a controller implemented for the refuse incineration plant in Hamburg-Stapelfeld, Germany.

  • PDF

Incineration of Waste Water Sludge and Coal In a Circulating Fluidized Bed Combustor (순환유동층에서 폐수슬러지와 석탄의 혼소 특성)

  • Bae, Dal-Hee;Shun, Do-Won;Park, Jae-Hyeon;Ryu, Ho-Jung;Park, Do-Hyun
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.165-172
    • /
    • 2004
  • Co-incineration of coal and wastewater sludge was r;erfonn:rl in a O.lMWth bench scale circulating fluidized bed combustor(CFBC) Sludge was received from a wastewater treatment plant in a dye industrial complex in Busan. Metropolis. Moisture content of received sludge was 80%. Coal and sludge mixture was prepared with weight ratio of 90/10, 85/15 and 80/20. Co-combustion characteristics of the coal and sludge mixture demonstrated stable combustion conditions. Component analysis, incineration characteristics, boiler performance was measured before and after the test and application for commercial 59MWth CFBC boiler. The release of hazardous components such as $SO_2$ and Cl was suppressed by the presence of inherent minerals of Ca, Na, K in coal and sludge mixture. Pre-drying was not essential but it was recommended for the benefits of manageability of sludge.

  • PDF

A Study on Behavior of Heavy Metals during Waste Incineration (폐기물 소각시 중금속 성분의 거동에 관한 연구)

  • 박용이;허철구
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.785-799
    • /
    • 1996
  • The incineration tests of mixed industrial wastes using the stoker type incinerator are carried out to investigate the partitioning characteristics of heavy metals during incineration. The results obtained from this study are as follow. The partitioning characteristics of heavy metals throughout this incinerator are found that, at given condition of $700^{\circ}C$, the elements with the relatively high boiling point such as Cr, Cu and Pb are partitioned into a bottom ash, a fry ash captured tv cyclone, and a flue gas stream, 67~88%, 2~19% and 6~16% of initial amount entering the incinerator, respectively, but the Cd and Hg of 75~81% is vaporized into the flue gas. It appears that the partitioning characteristics according to the particle size of ash is different between the bottom ash and the fly ash. For bottom ash, the fraction of partitioning into 75${\mu}{\textrm}{m}$ oversized particles is reatively high. For fly ash, the characteristics of distributions with the particle size can not be clearly shown.

  • PDF

Control of SCR System for NOx Reduction in a Refuse Incineration Plant Using Repetitive Control Method (반복제어법을 이용한 소각장 NOx 저감용 SCR 시스템의 제어)

  • 김인규;여태경;김환성;김상봉
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2762-2770
    • /
    • 2000
  • The refuse incineration plant has an important role in saving the combustion energy for local heating system. But harmful combustion gas(NOx etc.) leads to some serious environmental problem. To reduce the gas, a SCR(Selective Catalytic Reduction)system is installed and it is controlled by adjusting the flow of ammonia gas(NH3) . In this paper, we apply a repetitive control method to reduce NOx by adjusting the flow of ammonia gas for SCR system in a refuse incineration plant which is located in Haeundae, Pusan, Firstly, we analyze the inlet NOx period by FFt method, and verify its periodic variations. Secondly, we design a repetitive control system by using state space model method. Lastly, the effectiveness of repetitive control system is shown by comparing to a conventional PID control in simulation and experimental results.