• Title/Summary/Keyword: in-plane performance

Search Result 1,233, Processing Time 0.029 seconds

Ground Radiation Antenna for Mobile Devices Using Controlled Endless Metal Rim Mode

  • Jeon, Jihwan;Qu, Longyue;Lee, Hongkoo;Kim, Hyeongdong
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.180-187
    • /
    • 2018
  • In this paper, we introduce a ground radiation antenna that uses controlled endless metal rim modes. In the proposed technique, the metal rim mode is tuned and excited as a one-wavelength radiator by a small ground radiation antenna. The proposed antenna occupies a clearance of $1mm{\times}4mm$ in a $30mm{\times}20mm$ ground plane. A metal rim with dimensions of $34mm{\times}24mm$ surrounds the ground plane, and the metal rim is separated from the ground plane by a gap of 2 mm. In addition, a lumped capacitor is inserted between the metal rim and the ground plane to control the characteristic mode of the metal rim such that the resonance of the metal rim is tuned to be equal to the operating frequency. By performing simulations and measurements, we compare the performance of the proposed antenna with that of a reference antenna that does not have an inserted capacitor between the metal rim and the ground plane. The results show that a significant improvement of the radiation performance is obtained by employing the proposed technique.

Development of Plane Strain Punch Stretching Test (평면변형 장출실험기술의 개발)

  • 김영석;김기수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1132-1137
    • /
    • 1993
  • A simple simulative test was developed to evaluate stamping formability in plane strain stretching mode. The stamping formability was evaluated by limit punch height(LPH) in plane strain punch stretching test(PSST) compared to limit dome height(LDH) in hemispherical punch stretching test. PSST shows stable plane strain condition and good reproducibility with minimum scatter. Moreover LPH-value in PSST well ranks the stamping formability of various material and correlates with press performance.

Free Vibration Analysis of Plane Structures with Isogeometric Concept (등기하개념을 이용한 평면구조물의 자유진동해석)

  • Lee, Sang-Jin
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.171-182
    • /
    • 2019
  • Isogeometric concept is introduced to carry out free vibration analysis of plane structures. The geometry of structures is represented by using non-uniform rational B-spline surface (NURBS) and its basis function is consistently used in the formulation of plane stress element. In addition, multi-patch strategy is introduced to deal with the openings in building. The performance of the present isogeometric plane stress element is investigated by using five numerical examples. From numerical results, it is found to be that the isogeometric concept can successfully identify reliable natural frequencies and associated mode shapes of plane structures with/without openings in efficient way.

Determination of structural performance of 3D steel pipe rack suspended scaffolding systems

  • Arslan, Guray;Sevim, Baris;Bekiroglu, Serkan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.671-681
    • /
    • 2017
  • This study investigates the structural performance of 3D steel pipe rack suspended scaffolding systems. For the purpose, a standard full scale 3D steel pipe rack suspended scaffolding system considering two frames, two plane trusses, purlins and wooden floor is constructed in the laboratory. A developed load transmission system was placed in these experimental systems to distribute single loads to the center of a specific area in a step-by-step manner using a load jack. After each load increment, the displacements are measured by means of linear variable differential transducers placed in several critical points of the system. The tests are repeated for five different system conditions to determine the structural performance. The means of system conditions is the numbers of the tie bars which are used to connect plane trusses under level. Finite elements models of the 3D steel pipe rack suspended scaffolding systems considering different systems conditions are constituted using SAP2000 software to support the experimental tests and to use the models in future studies. Each of models including load transmission platform is analyzed under a single loading and the displacements are obtained. In addition, to calibrate the numerical models some uncertain parameters such as elasticity modulus of wooden floor and connection rigidity of purlins to plane trusses are assessed experimentally. The results of this work demonstrate that when increasing numbers of tie bars the displacement values are decreased. Also the results obtained from developed numerical models have harmony with those of experimental. In addition, the scaffolding system with two tie bars at the beginning and at the end of the plane truss has the optimum structural performance compared the results obtained for other scaffolding system conditions.

Underwater E-plane Attenuation Model of Omnidirectional Antenna Using Half Power Beam Width (HPBW) (반전력빔폭을 이용한 전방향성 안테나의 수중 환경 수직 평면 감쇠 모델)

  • Kwak, Kyungmin;Park, Daegil;Kim, Younghyeon;Chung, Wan Kyun;Kim, Jinhyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1050-1056
    • /
    • 2015
  • In this paper, we use the characteristics of electromagnetic waves underwater attenuation for estimating linear distance between a transmitting node and receiving node, and research underwater vertical plane attenuation model for constructing the underwater localization system. The underwater localization of 2 dimensional with the plane attenuation model in the horizontal plane (H-plane) was proposed previous research. But for the 3 dimensional underwater localization, the additional vertical plane (E-plane) model should be considered. Because the horizontal plane of omnidirectional antenna has the same attenuation tendency in x-y plane according to the distance, whereas in vertical plane shows an irregular pattern in x-z plane. For that reason, in the vertical plane environment, the attenuation should be changed by the position and inclination. Hence, in this paper the distance and angle between transmitting and receiving node are defined using spherical coordinate system and derive an antenna gain pattern using half power beam width (HPBW). The HPBW is called a term which defines antenna's performance between isotropic and other antennas. This paper derives omnidirectional antenna's maximum gain and attenuation pattern model and define vertical plane's gain pattern model using HPBW. Finally, experimental verifications for the proposed underwater vertical plane's attenuation model was executed.

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

Ranking-based Flow Replacement Method for Highly Scalable SDN (고확장성 SDN을 위한 랭킹 기반 플로우 교체 기법)

  • Tri, Hiep T. Nguyen;Kim, Kyungbaek
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.143-146
    • /
    • 2015
  • Software Defined Network (SDN) separates control plane and data plane to achieve benefits such as centralized management, centralized provisioning, lower device cost and more flexibility. In SDN, scalability is an important issue. Centralized controller can be a bottle neck and many research tried to solve this issue on the control plan. However, scalability issue does not only happen in the control plane, but also happen in the data plane. In the data plane, flow table is an important component and its size is limited. In a large network operated by SDN technology, the performance of the network can be highly degraded because of the size limitation of a flow table. In this paper, we propose a ranking-based flow replacement method, Flow Table Management (FTM), to overcome this problem.

Lossless Coding of Audio Spectral Coefficients Using Selective Bit-Plane Coding (선택적 비트 플레인 부호화를 이용한 오디오 주파수 계수의 무손실 부호화 기술)

  • Yoo, Seung-Kwan;Park, Ho-Chong;Oh, Seoung-Jun;Ahn, Chang-Beom;Sim, Dong-Gyu;Beak, Seung-Kwon;Kang, Kyoung-Ok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.18-25
    • /
    • 2008
  • In this paper, new lossless coding method of spectral coefficients for audio codec is proposed. Conventional lossless coder uses Huffman coding utilizing the statistical characteristics of spectral coefficients, but does not provide the high coding efficiency due to its simple structure. To solve this limitation, new lossless coding scheme with better performance is proposed that consists of bit-plane transform and run-length coding. In the proposed scheme, the spectral coefficients are first transformed by bit-plane into 1-D bit-stream with better correlative properties, which is then coded intorun-length and is finally Huffman coded. In addition, the coding performance is further increased by applying the proposed bit-plane coding selectively to each group, after the entire frequency is divided into 3 groups. The performance of proposed coding scheme is measured in terms of theoretical number of bits based on the entropy, and shows at most 6% enhancement compared to that of conventional lossless coder used in AAC audio codec.

A Numerical Study on the Performance Improvement of Guide Vanes in an Axial-flow Pump (축류펌프 안내깃의 성능 향상을 위한 수치해석적 연구)

  • Park, Hyun-Chang;Kim, Sung;Yoon, Joon-Yong;Choi, Young-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.58-63
    • /
    • 2012
  • This paper presents a numerical study on the performance improvement of axial-flow pump with guide vanes. Design optimization for guide vanes in an axial-flow pump has been studied through the implementation of a commercial CFD code and DOE (design of experiments). We also discussed how to improve the performance of the axial-flow pump by designing the guide vanes. Geometric design variables were defined by the meridional plane and vane plane development of guide vanes. The effect of hub tip ratio analyzed the meridional plane of guide vanes. The importance of the geometric design variables was analyzed using $2^k$ factorial designs. The objective functions for guide vane geometric variables were defined as the total efficiency and the total head at the design flow rate. From the $2^k$ factorial design results, the important design variables were found and the performance was increased in comparison with the base design model.

Electro-Optic Characteristics according to Distance between Pixel Electrodes in Fringe In-plane field Switching mode (화소 전극 간 거리가 Fringe In-plane field Switching mode의 전기 광학 특성에 미치는 영향)

  • Kim, Min-Su;Park, Ji-Woong;Jung, Jun-Ho;Ha, Kyung-Su;Lim, Young-Jin;Lee, Myong-Hoon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.337-338
    • /
    • 2008
  • We have studied electro-optic characteristics of a high performance liquid crystal display using Fringe In-plane field Switching (FIS) mode. The strong electric fields cause more liquid crystals to reorient almost in plane above and between the pixel electrodes. As a result, the operation voltage is lower and transmittance is higher than those of Fringe Field Switching (FFS) and In-Plane Switching (IPS) modes. Apparently, the transmittance depends on voltage applied at the configurations of FIS mode which are proposed. Therefore, we have studied certain length of between electrodes for maximum transmittance and light intensity.

  • PDF